메뉴 건너뛰기




Volumn 56, Issue 5, 2009, Pages 2972-2978

Energy resolution of calcium co-doped LSO:Ce scintillators

Author keywords

Afterglow; Energy resolution; Lu2SiO 5; Lutetium oxyorthosilicate; Non proportionality

Indexed keywords

AFTERGLOW; ENERGY RESOLUTION; LU2SIO 5; LUTETIUM OXYORTHOSILICATE; NON-PROPORTIONALITY;

EID: 70350173274     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2009.2028235     Document Type: Article
Times cited : (24)

References (16)
  • 1
    • 0026902676 scopus 로고
    • Cerium-doped lutetium oxyorthosilicate: A fast, efficient new scintillator
    • Aug.
    • C. L. Melcher and J. S. Schweitzer, "Cerium-doped lutetium oxyorthosilicate: A fast, efficient new scintillator," IEEE Trans. Nucl. Sci., vol.39, no.4, pp. 502-505, Aug. 1992.
    • (1992) IEEE Trans. Nucl. Sci. , vol.39 , Issue.4 , pp. 502-505
    • Melcher, C.L.1    Schweitzer, J.S.2
  • 6
    • 0028430949 scopus 로고
    • Afterglow and thermoluminescence properties of Lu SiO :Ce scintillation crystals
    • P. Dorenbos, C. W. E. Van Eijk, A. J. J. Bos, and C. L. Melcher, "Afterglow and thermoluminescence properties of Lu SiO :Ce scintillation crystals," J. Phys. Condens. Matter, vol.6, pp. 4167-4180, 1994.
    • (1994) J. Phys. Condens. Matter , vol.6 , pp. 4167-4180
    • Dorenbos, P.1    Van Eijk, C.W.E.2    Bos, A.J.J.3    Melcher, C.L.4
  • 9
    • 33645687106 scopus 로고    scopus 로고
    • TUKAN-An 8 K pulse height analyzer and multi-channel scaler with a PCI or a USB interface
    • Feb.
    • Z. Guzik, S. Borsuk, K. Traczyk, and M. Pomiński, "TUKAN-An 8 K pulse height analyzer and multi-channel scaler with a PCI or a USB interface," IEEE Trans. Nucl. Sci., vol.53, no.1, pp. 231-235, Feb. 2006.
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , Issue.1 , pp. 231-235
    • Guzik, Z.1    Borsuk, S.2    Traczyk, K.3    Pomiński, M.4
  • 10
    • 0042321040 scopus 로고
    • A technique for absolute measurement of the effective photoelectron per keV yield in scintillation counters
    • Versailles, France
    • M. Bertolaccini, S. Cova, and C. Bussolatti, "A technique for absolute measurement of the effective photoelectron per keV yield in scintillation counters," in Proc. Nuclear Electronics Symp., Versailles, France, 1968.
    • (1968) Proc. Nuclear Electronics Symp.
    • Bertolaccini, M.1    Cova, S.2    Bussolatti, C.3
  • 12
    • 31844438733 scopus 로고    scopus 로고
    • Energy resolution of scintillation detectors
    • Article No. 592205
    • M. Moszyński, "Energy resolution of scintillation detectors," Proc. SPIE , vol.5922, pp. 1-14, 2005, Article No. 592205.
    • (2005) Proc. SPIE , vol.5922 , pp. 1-14
    • Moszyński, M.1
  • 14
    • 0029548037 scopus 로고
    • Non-proportionality in the scintillation response and the energy resolution obtainable with scintillation crystals
    • Dec.
    • P. Dorenbos, J. T. M. De Haas, and C. W. E. Van Eijk, "Non-proportionality in the scintillation response and the energy resolution obtainable with scintillation crystals," IEEE Trans. Nucl. Sci., vol.42, no.6, pp. 2190-2202, Dec. 1995.
    • (1995) IEEE Trans. Nucl. Sci. , vol.42 , Issue.6 , pp. 2190-2202
    • Dorenbos, P.1    De Haas, J.T.M.2    Van Eijk, C.W.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.