메뉴 건너뛰기




Volumn 23, Issue 10, 2009, Pages 2345-2350

Real-time probe measurement of tissue oxygenation during gastrointestinal stapling: Mucosal ischemia occurs and is not influenced by staple height

Author keywords

Abdominal; Anastomosis; Ischemia; Staplers; T Stat; Tissue hemoglobin oxygen saturation

Indexed keywords

ANASTOMOSIS; ANIMAL EXPERIMENT; ARTICLE; BLOOD FLOWMETRY; COLON; INTESTINE ISCHEMIA; INTESTINE RESECTION; INTESTINE SURGERY; INTRAOPERATIVE PERIOD; LAPAROTOMY; MEASUREMENT; MOLECULAR PROBE; MUCOSA; NONHUMAN; OXYGEN SATURATION; PRIORITY JOURNAL; REPRODUCIBILITY; SEROSA; SMALL INTESTINE; STAPLER; SWINE; TISSUE OXYGENATION;

EID: 70350029438     PISSN: 09302794     EISSN: 14322218     Source Type: Journal    
DOI: 10.1007/s00464-009-0342-5     Document Type: Article
Times cited : (19)

References (10)
  • 1
    • 35348933215 scopus 로고    scopus 로고
    • Morbidity of anastomotic leaks in patients undergoing Roux-en-Y gastric bypass
    • DOI 10.1001/archsurg.142.10.954
    • T Almahmeed R Gonzalez L Nelson K Haines S Gallagher M Murr 2007 Morbidity of anastomotic leaks in patients undergoing Roux-en-Y gastric bypass Arch Surg 142 954 957 10.1001/archsurg.142.10.954 17938308 (Pubitemid 47607602)
    • (2007) Archives of Surgery , vol.142 , Issue.10 , pp. 954-957
    • Almahmeed, T.1    Gonzalez, R.2    Nelson, L.G.3    Haines, K.4    Gallagher, S.F.5    Murr, M.M.6
  • 2
    • 1542346421 scopus 로고    scopus 로고
    • Experience with over 3,000 open and laparoscopic bariatric procedures: Multivariate analysis of factors related to leak and resultant mortality
    • DOI 10.1007/s00464-003-8926-y
    • A Fernandez E DeMaria D Tichansky J Kellum L Wolfe J Meador H Sugerman 2004 Experience with over 3,000 open and laparoscopic bariatric procedures Surg Endosc 18 193 197 10.1007/s00464-003-8926-y 14691697 (Pubitemid 38298836)
    • (2004) Surgical Endoscopy , vol.18 , Issue.2 , pp. 193-197
    • Fernandez Jr., A.Z.1    DeMaria, E.J.2    Tichansky, D.S.3    Kellum, J.M.4    Wolfe, L.G.5    Meador, J.6    Sugerman, H.J.7
  • 4
    • 0034182889 scopus 로고    scopus 로고
    • Development of a new instrument to measure saturation and total hemoglobin volume in local skin by near-infrared spectroscopy and its clinical application
    • 10.1007/s004840050133 1:STN:280:DC%2BD3czjsFOksg%3D%3D 10879423
    • Y Nagashima Y Yada M Hattori A Sakai 2000 Development of a new instrument to measure saturation and total hemoglobin volume in local skin by near-infrared spectroscopy and its clinical application Int J Biometeorol 44 11 19 10.1007/s004840050133 1:STN:280:DC%2BD3czjsFOksg%3D%3D 10879423
    • (2000) Int J Biometeorol , vol.44 , pp. 11-19
    • Nagashima, Y.1    Yada, Y.2    Hattori, M.3    Sakai, A.4
  • 5
    • 33847317966 scopus 로고    scopus 로고
    • Skeletal muscle oxygen saturation does not estimate mixed venous oxygen saturation in patients with severe left heart failure and additional severe sepsis or septic shock
    • DOI 10.1186/cc5153
    • M Podbregar H Mozina 2007 Skeletal muscle oxygen saturation does not estimate mixed venous saturation in patients with severe left heart failure and additional severe sepsis or septic shock Crit Care 11 R6 10.1186/cc5153 17227587 (Pubitemid 46322027)
    • (2007) Critical Care , vol.11
    • Podbregar, M.1    Mozina, H.2
  • 6
    • 33846435695 scopus 로고    scopus 로고
    • Diagnosis of chronic mesenteric ischemia by visible light spectroscopy during endoscopy
    • DOI 10.1016/j.gie.2006.05.007, PII S0016510706019547
    • S Friedland D Benaron S Coogan D Sze R Soetikno 2007 Diagnosis of chronic mesenteric ischemia by visible light spectroscopy during endoscopy Gastrointest Endosc 65 294 300 10.1016/j.gie.2006.05.007 17137857 (Pubitemid 46148892)
    • (2007) Gastrointestinal Endoscopy , vol.65 , Issue.2 , pp. 294-300
    • Friedland, S.1    Benaron, D.2    Coogan, S.3    Sze, D.Y.4    Soetikno, R.5
  • 7
    • 70350012582 scopus 로고    scopus 로고
    • Reflectance spectrometry as intraoperative assessment of perfusion in rectal anastomosis, a feasibility study (abstract)
    • A Karliczek D Benaron P Baas A van der Stoel T Wiggers G van Dam 2007 Reflectance spectrometry as intraoperative assessment of perfusion in rectal anastomosis, a feasibility study (abstract) Eur Surg Res 39 Suppl 1 O.025
    • (2007) Eur Surg Res , vol.39 , Issue.SUPPL 1 , pp. 025
    • Karliczek, A.1    Benaron, D.2    Baas, P.3    Van Der Stoel, A.4    Wiggers, T.5    Van Dam, G.6
  • 8
    • 3142547201 scopus 로고    scopus 로고
    • Reflectance spectrophotometry for the assessment of mucosal perfusion in the gastrointestinal tract
    • DOI 10.1016/j.giec.2004.03.011, PII S105251570400056X
    • S Friedland R Soetikno D Benaron 2004 Reflectance spectrophotometry for the assessment of mucosal perfusion in the gastrointestinal tract Gastrointest Endosc Clin North Am 14 539 553 10.1016/j.giec.2004.03.011 (Pubitemid 38903217)
    • (2004) Gastrointestinal Endoscopy Clinics of North America , vol.14 , Issue.3 , pp. 539-553
    • Friedland, S.1    Soetikno, R.2    Benaron, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.