Volumn 49, Issue 1, 2010, Pages 345-354

Construction and assessment of a 3-T MRI brain template

Author keywords

3 T MRI; Basal ganglia; Brain template; Deep brain stimulation

Indexed keywords

ADULT; ARTICLE; BASAL GANGLION; BRAIN DEPTH STIMULATION; CONTROLLED STUDY; DIGITAL IMAGING; GRAY MATTER; HUMAN; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTRARATER RELIABILITY; MALE; NEUROANATOMY; NEUROIMAGING; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; VALIDATION PROCESS; WHITE MATTER;

EID: 70350026667     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2009.08.007     Document Type: Article
Times cited : (37)

References (49)
  • 1
    • 33746094676 scopus 로고    scopus 로고
    • A new improved version of the realistic digital brain phantom
    • Aubert-Broche B., Evans A.C., and Collins L. A new improved version of the realistic digital brain phantom. NeuroImage 32 (2006) 138-145
    • (2006) NeuroImage , vol.32 , pp. 138-145
    • Aubert-Broche, B.1    Evans, A.C.2    Collins, L.3
  • 2
    • 70350036699 scopus 로고    scopus 로고
    • A three-dimensional histological atlas of the human basal ganglia. II. Atlas deformation strategy and evaluation in deep brain stimulation for Parkinson disease
    • Bardinet E., Bhattacharjee M., Dormont D., Pidoux B., Malandain G., Schüpbach M., Ayache N., Cornu P., Agid Y., and Yelnik J. A three-dimensional histological atlas of the human basal ganglia. II. Atlas deformation strategy and evaluation in deep brain stimulation for Parkinson disease. J. Neurosurg. 31 (2008) 1-12
    • (2008) J. Neurosurg. , vol.31 , pp. 1-12
    • Bardinet, E.1    Bhattacharjee, M.2    Dormont, D.3    Pidoux, B.4    Malandain, G.5    Schüpbach, M.6    Ayache, N.7    Cornu, P.8    Agid, Y.9    Yelnik, J.10
  • 4
    • 33645127544 scopus 로고    scopus 로고
    • The creation of a brain atlas for image guided neurosurgery using serial histological data
    • Chakravarty M., Bertrand G., Hodge C.P., Sadikot A.F., and Collins D.L. The creation of a brain atlas for image guided neurosurgery using serial histological data. NeuroImage 30 2 (2006) 359-376
    • (2006) NeuroImage , vol.30 , Issue.2 , pp. 359-376
    • Chakravarty, M.1    Bertrand, G.2    Hodge, C.P.3    Sadikot, A.F.4    Collins, D.L.5
  • 6
    • 0037341499 scopus 로고    scopus 로고
    • Acutance, an objective measure of retinal nerve fibre image clarity
    • Choong Y.F., Rakebrfsandt F., and Morgan J.E. Acutance, an objective measure of retinal nerve fibre image clarity. Br. J. Ophthalmol. 87 (2003) 322-326
    • (2003) Br. J. Ophthalmol. , vol.87 , pp. 322-326
    • Choong, Y.F.1    Rakebrfsandt, F.2    Morgan, J.E.3
  • 7
    • 84883843392 scopus 로고    scopus 로고
    • Fast non local means denoising for 3D MR images. MICCAI'06
    • International Conference on Medical Image Computing and Computer Assisted Intervention, Springer, Copenhaguen, Denmark
    • Coupé, P., Yger, P., Barillot, C., 2006. Fast non local means denoising for 3D MR images. MICCAI'06, International Conference on Medical Image Computing and Computer Assisted Intervention, in Lecture Notes in Computer Science, Springer, Copenhaguen, Denmark, 4191, 33-40.
    • (2006) Lecture Notes in Computer Science , vol.4191 , pp. 33-40
    • Coupé, P.1    Yger, P.2    Barillot, C.3
  • 8
    • 41649106122 scopus 로고    scopus 로고
    • An optimized blockwise non local means denoising filter for 3D magnetic resonance images
    • Coupé P., Yger P., Prima S., Hellier P., Kervram C., and Barillot C. An optimized blockwise non local means denoising filter for 3D magnetic resonance images. IEEE Trans. Med. Imag. 24 4 (2008) 425-441
    • (2008) IEEE Trans. Med. Imag. , vol.24 , Issue.4 , pp. 425-441
    • Coupé, P.1    Yger, P.2    Prima, S.3    Hellier, P.4    Kervram, C.5    Barillot, C.6
  • 9
    • 27744524665 scopus 로고    scopus 로고
    • Computer-aided placement of deep brain stimulators: from planning to intraoperative guidance
    • D'Haese P.F., Cetinkaya E., Konrad P.E., Kao C., and Dawant M.B. Computer-aided placement of deep brain stimulators: from planning to intraoperative guidance. IEEE Trans. Med. Imag. 24 11 (2005) 1469-1478
    • (2005) IEEE Trans. Med. Imag. , vol.24 , Issue.11 , pp. 1469-1478
    • D'Haese, P.F.1    Cetinkaya, E.2    Konrad, P.E.3    Kao, C.4    Dawant, M.B.5
  • 12
    • 0037810601 scopus 로고    scopus 로고
    • Three-dimensional database of subcortical electrophysiology for image-guided stereotactic functional neurosurgery
    • Finnis K.W., Starreveld Y.P., Parrent A.G., Sadikot A.F., and Peters T.M. Three-dimensional database of subcortical electrophysiology for image-guided stereotactic functional neurosurgery. IEEE Trans. Med. Imag. 22 1 (2003) 93-104
    • (2003) IEEE Trans. Med. Imag. , vol.22 , Issue.1 , pp. 93-104
    • Finnis, K.W.1    Starreveld, Y.P.2    Parrent, A.G.3    Sadikot, A.F.4    Peters, T.M.5
  • 13
    • 0038236731 scopus 로고    scopus 로고
    • Magnetic resonance imaging at 3.0 Tesla: challenges and advantages in clinical neurological imaging
    • Frayne R., Goodyear B.G., Dickhoff P., Lauzon M.L., and Sevick R.J. Magnetic resonance imaging at 3.0 Tesla: challenges and advantages in clinical neurological imaging. Invest. Radiol. 38 (2003) 385-402
    • (2003) Invest. Radiol. , vol.38 , pp. 385-402
    • Frayne, R.1    Goodyear, B.G.2    Dickhoff, P.3    Lauzon, M.L.4    Sevick, R.J.5
  • 15
    • 35349001856 scopus 로고    scopus 로고
    • Gray matter-white matter contrast on spin-echo T1-weighted images at 3 T and 1.5 T: a quantitative comparison study
    • Fushimi Y., Miki Y., Urayama S., Okada T., Mori N., Hanakawa T., Fukuyama H., and Togashi K. Gray matter-white matter contrast on spin-echo T1-weighted images at 3 T and 1.5 T: a quantitative comparison study. Eur. Radiol. 17 11 (2007) 2921-2925
    • (2007) Eur. Radiol. , vol.17 , Issue.11 , pp. 2921-2925
    • Fushimi, Y.1    Miki, Y.2    Urayama, S.3    Okada, T.4    Mori, N.5    Hanakawa, T.6    Fukuyama, H.7    Togashi, K.8
  • 16
    • 36849093538 scopus 로고    scopus 로고
    • Surgical targeting accuracy analysis of six methods for subthalamic nucleus deep brain stimulation
    • Guo T., Parrent A.G., and Peters T.M. Surgical targeting accuracy analysis of six methods for subthalamic nucleus deep brain stimulation. Comp. Aid Surg. 12 6 (2007) 325-334
    • (2007) Comp. Aid Surg. , vol.12 , Issue.6 , pp. 325-334
    • Guo, T.1    Parrent, A.G.2    Peters, T.M.3
  • 17
    • 13844266851 scopus 로고    scopus 로고
    • Functional 3.0-T MR assessment of higher cognitive function: are there advantages over 1.5-T imaging?
    • Hoenig K., Kuhl C.K., and Scheef L. Functional 3.0-T MR assessment of higher cognitive function: are there advantages over 1.5-T imaging?. Radiology 234 (2005) 860-868
    • (2005) Radiology , vol.234 , pp. 860-868
    • Hoenig, K.1    Kuhl, C.K.2    Scheef, L.3
  • 19
    • 70350016023 scopus 로고    scopus 로고
    • Methods in astronomical image processing with special applications to the reduction of CCD data
    • Jorsater S. Methods in astronomical image processing with special applications to the reduction of CCD data. Lect. Notes Phys. 413 (2006) 193-207
    • (2006) Lect. Notes Phys. , vol.413 , pp. 193-207
    • Jorsater, S.1
  • 20
    • 67149112119 scopus 로고    scopus 로고
    • Post-operative assessment in deep brain stimulation based on multimodal images: Registration workflow and validation
    • Orlando, FL
    • Lalys, F., Haegelen, C., Abadie, A., Jannin, P., 2009. Post-operative assessment in deep brain stimulation based on multimodal images: registration workflow and validation. Proceedings of SPIE: Medical Imaging, Orlando, FL, 7261.
    • (2009) Proceedings of SPIE: Medical Imaging , pp. 7261
    • Lalys, F.1    Haegelen, C.2    Abadie, A.3    Jannin, P.4
  • 21
    • 0032497504 scopus 로고    scopus 로고
    • Parkinson's disease. First of two parts
    • Lang A.E., and Lozano A.M. Parkinson's disease. First of two parts. N. Engl. J. Med. 339 15 (1998) 1044-1053
    • (1998) N. Engl. J. Med. , vol.339 , Issue.15 , pp. 1044-1053
    • Lang, A.E.1    Lozano, A.M.2
  • 24
    • 13844256798 scopus 로고    scopus 로고
    • Three-dimensional dynamic susceptibility-weighted perfusion MR imaging at 3.0 T: feasibility and contrast agent dose
    • Manka C., Traber F., Gieseke J., Schild H.H., and Kuhl C.K. Three-dimensional dynamic susceptibility-weighted perfusion MR imaging at 3.0 T: feasibility and contrast agent dose. Radiology 234 (2005) 869-877
    • (2005) Radiology , vol.234 , pp. 869-877
    • Manka, C.1    Traber, F.2    Gieseke, J.3    Schild, H.H.4    Kuhl, C.K.5
  • 26
    • 0033470448 scopus 로고    scopus 로고
    • Catalog of four-color photometry of stars, galaxies, and QSOS using SDSS filters
    • Newberg H.J., Richards G.T., Richmond M., and Fan X. Catalog of four-color photometry of stars, galaxies, and QSOS using SDSS filters. Astrophys. J., Supl. Ser. 123 2 (1999) 377-435
    • (1999) Astrophys. J., Supl. Ser. , vol.123 , Issue.2 , pp. 377-435
    • Newberg, H.J.1    Richards, G.T.2    Richmond, M.3    Fan, X.4
  • 30
    • 0032843554 scopus 로고    scopus 로고
    • An adaptive fuzzy C-means algorithm for image segmentation in the presence of intensity inhomogeneities
    • Pham D.L., and Prince J.L. An adaptive fuzzy C-means algorithm for image segmentation in the presence of intensity inhomogeneities. Pattern Recogn. Lett. 20 1 (1999) 57-68
    • (1999) Pattern Recogn. Lett. , vol.20 , Issue.1 , pp. 57-68
    • Pham, D.L.1    Prince, J.L.2
  • 33
    • 1242294355 scopus 로고    scopus 로고
    • The high-field-strength curmudgeon
    • Ross J.S. The high-field-strength curmudgeon. AMJN Am. J. Neuroradiol. 25 (2004) 168-169
    • (2004) AMJN Am. J. Neuroradiol. , vol.25 , pp. 168-169
    • Ross, J.S.1
  • 34
    • 33750818076 scopus 로고    scopus 로고
    • A cross validation study of deep brain stimulation targeting: from experts to atlas-based, segmentation-based and automatic registration
    • Sanchez Castro F., Pollo C., Meuli R., Maeder P., Culsenaire O., Bach Cuadra M., Villemure J., and Thiran J. A cross validation study of deep brain stimulation targeting: from experts to atlas-based, segmentation-based and automatic registration. IEEE Trans. Med. Imag. 25 11 (2006) 1440-1450
    • (2006) IEEE Trans. Med. Imag. , vol.25 , Issue.11 , pp. 1440-1450
    • Sanchez Castro, F.1    Pollo, C.2    Meuli, R.3    Maeder, P.4    Culsenaire, O.5    Bach Cuadra, M.6    Villemure, J.7    Thiran, J.8
  • 35
    • 27744508263 scopus 로고    scopus 로고
    • High-field MRI of the central nervous system: current approaches to clinical and microscopic imaging
    • Sasaki M., Inoue T., Tohyama K., Oikawa H., Ehara S., and Ogawa A. High-field MRI of the central nervous system: current approaches to clinical and microscopic imaging. Magn. Reson. Med. Sci. 2 (2003) 133-139
    • (2003) Magn. Reson. Med. Sci. , vol.2 , pp. 133-139
    • Sasaki, M.1    Inoue, T.2    Tohyama, K.3    Oikawa, H.4    Ehara, S.5    Ogawa, A.6
  • 38
    • 79551689255 scopus 로고    scopus 로고
    • Fully Bayesian joint model for MR brain tissue and structure segmentation. MICCAI'08
    • International Conference on Medical Image Computing and Computer Assisted Intervention, Springer, New York, USA
    • Scherrer, B., Forbes, F., Garbay, C., Dojat, M., 2008. Fully Bayesian joint model for MR brain tissue and structure segmentation. MICCAI'08, International Conference on Medical Image Computing and Computer Assisted Intervention, in Lecture Notes in Computer Science, Springer, New York, USA, 5242, 1066-1074.
    • (2008) Lecture Notes in Computer Science , vol.5242 , pp. 1066-1074
    • Scherrer, B.1    Forbes, F.2    Garbay, C.3    Dojat, M.4
  • 39
    • 22844444193 scopus 로고    scopus 로고
    • Whole-body MRI at high field: technical limits and clinical potential
    • Schick F. Whole-body MRI at high field: technical limits and clinical potential. Eur. Radiol. 15 (2005) 946-959
    • (2005) Eur. Radiol. , vol.15 , pp. 946-959
    • Schick, F.1
  • 40
    • 20344386763 scopus 로고    scopus 로고
    • Construction of a brain template from MR images using state-of-the-art registration and segmentation techniques
    • Seghers D., D'Agostino E., Maes F., Vandermeulen D., and Suetens P. Construction of a brain template from MR images using state-of-the-art registration and segmentation techniques. Lect. Notes Comput. Sci. 3216 (2004) 696-703
    • (2004) Lect. Notes Comput. Sci. , vol.3216 , pp. 696-703
    • Seghers, D.1    D'Agostino, E.2    Maes, F.3    Vandermeulen, D.4    Suetens, P.5
  • 41
    • 0032173356 scopus 로고    scopus 로고
    • Automated atlas integration and interactive three-dimensional visualization tools for planning and guidance in funcionnal neurosurgery
    • St-Jean P., Sadikot A.F., Collins L., Clonda D., Kasrai R., Evans A.C., and Peters T.M. Automated atlas integration and interactive three-dimensional visualization tools for planning and guidance in funcionnal neurosurgery. IEEE Trans. Med. Imag. 17(5) (1998) 672-680
    • (1998) IEEE Trans. Med. Imag. , vol.17 5 , pp. 672-680
    • St-Jean, P.1    Sadikot, A.F.2    Collins, L.3    Clonda, D.4    Kasrai, R.5    Evans, A.C.6    Peters, T.M.7
  • 44
    • 0035960120 scopus 로고    scopus 로고
    • Deep-brain stimulation of the subthalamic nucleus or the pars interna of the globus pallidus in Parkinson's disease
    • The Deep-Brain Stimulation for Parkinson's Disease Study Group
    • The Deep-Brain Stimulation for Parkinson's Disease Study Group. Deep-brain stimulation of the subthalamic nucleus or the pars interna of the globus pallidus in Parkinson's disease. N. Engl. J. Med. 345 13 (2001) 956-963
    • (2001) N. Engl. J. Med. , vol.345 , Issue.13 , pp. 956-963
  • 45
    • 33847774807 scopus 로고    scopus 로고
    • A review of methods for correction of intensity inhomogneity in MRI
    • Vovk U., Pernus F., and Likar B. A review of methods for correction of intensity inhomogneity in MRI. IEEE Trans. Med. Imag. 26 3 (2007) 405-421
    • (2007) IEEE Trans. Med. Imag. , vol.26 , Issue.3 , pp. 405-421
    • Vovk, U.1    Pernus, F.2    Likar, B.3
  • 46
    • 36248959770 scopus 로고    scopus 로고
    • Evaluation of a new optimization algorithm for rigid registration of MRI data
    • Wiest-Daesslé N., Yger P., Prima S., and Barillot C. Evaluation of a new optimization algorithm for rigid registration of MRI data. Proc. SPIE: Med. Imag. 6512 (2007) 601-610
    • (2007) Proc. SPIE: Med. Imag. , vol.6512 , pp. 601-610
    • Wiest-Daesslé, N.1    Yger, P.2    Prima, S.3    Barillot, C.4
  • 47
    • 33751518806 scopus 로고    scopus 로고
    • A three-dimensional, histological and deformable atlas of the human basal ganglia. I. Atlas construction based on immunohistochemical and MRI data
    • Yelnik J., Bardinet E., Dormont D., Malandain G., Ourselin S., Tandé D., Karachi C., Ayache N., Cornu P., and Agid Y. A three-dimensional, histological and deformable atlas of the human basal ganglia. I. Atlas construction based on immunohistochemical and MRI data. NeuroImage 34 2 (2007) 618-638
    • (2007) NeuroImage , vol.34 , Issue.2 , pp. 618-638
    • Yelnik, J.1    Bardinet, E.2    Dormont, D.3    Malandain, G.4    Ourselin, S.5    Tandé, D.6    Karachi, C.7    Ayache, N.8    Cornu, P.9    Agid, Y.10
  • 48
    • 0036156533 scopus 로고    scopus 로고
    • Pulsed arterial spin labelling: comparison of multisection baseline and functional MR imaging perfusion signal at 1.5 and 3.0 T: initial results in six subjects
    • Yongbi M.N., Fera F., Yang Y., Frank J.A., and Duyn J.H. Pulsed arterial spin labelling: comparison of multisection baseline and functional MR imaging perfusion signal at 1.5 and 3.0 T: initial results in six subjects. Radiology 222 (2002) 569-575
    • (2002) Radiology , vol.222 , pp. 569-575
    • Yongbi, M.N.1    Fera, F.2    Yang, Y.3    Frank, J.A.4    Duyn, J.H.5
  • 49
    • 28244485448 scopus 로고    scopus 로고
    • Segmentation of subcortical brain structures using fuzzy templates
    • Zhou J., and Rajapakse J.C. Segmentation of subcortical brain structures using fuzzy templates. NeuroImage 28 4 (2005) 915-924
    • (2005) NeuroImage , vol.28 , Issue.4 , pp. 915-924
    • Zhou, J.1    Rajapakse, J.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.