메뉴 건너뛰기




Volumn 42, Issue 13, 2009, Pages 1923-1939

Simultaneous potentiometric determination of thiamine and pyridoxine in multivitamins using a single cyclodextrin-based thiamine-selective electrode

Author keywords

ISE; Partial least squares regression; Pyridoxine; SIA; Thiamine

Indexed keywords


EID: 70350005085     PISSN: 00032719     EISSN: 1532236X     Source Type: Journal    
DOI: 10.1080/00032710903082549     Document Type: Article
Times cited : (5)

References (24)
  • 1
    • 31544450016 scopus 로고    scopus 로고
    • RP-HPLC determination of vitamins B-1, B-3, B-6, folic acid, and B-12 in multivitamin tablets
    • Amidzic, R., J. Brboric, O. Cudina, and S. Vladimirov. 2005. RP-HPLC determination of vitamins B-1, B-3, B-6, folic acid, and B-12 in multivitamin tablets. J. Serb. Chem. Soc. 70: 1229-1235.
    • (2005) J. Serb. Chem. Soc. , vol.70 , pp. 1229-1235
    • Amidzic, R.1    Brboric, J.2    Cudina, O.3    Vladimirov, S.4
  • 2
    • 0035019536 scopus 로고    scopus 로고
    • Simultaneous determination of thiamine and pyridoxine in pharmaceuticals by using a single flow-through biparameter sensor
    • Barrales, P. O., A. D. Vidal, M. L. F. de Cordova, and A. M. Diaz. 2001. Simultaneous determination of thiamine and pyridoxine in pharmaceuticals by using a single flow-through biparameter sensor. J. Pharm. Biomed. Anal. 25: 619-630.
    • (2001) J. Pharm. Biomed. Anal. , vol.25 , pp. 619-630
    • Barrales, P.O.1    Vidal, A.D.2    de Cordova, M.L.F.3    Diaz, A.M.4
  • 3
    • 7844252729 scopus 로고    scopus 로고
    • Development of a validated HPLC method for the determination of B-complex vitamins in pharmaceuticals and biological fluids after solid phase extraction
    • Chatzimichalakis, P. F., V. F. Samanidou, R. Verpoorte, and I. N. Papadoyannis. 2004. Development of a validated HPLC method for the determination of B-complex vitamins in pharmaceuticals and biological fluids after solid phase extraction. J. Sep. Sci. 27: 1181-1188.
    • (2004) J. Sep. Sci. , vol.27 , pp. 1181-1188
    • Chatzimichalakis, P.F.1    Samanidou, V.F.2    Verpoorte, R.3    Papadoyannis, I.N.4
  • 4
    • 0035745095 scopus 로고    scopus 로고
    • Chemometric quantitative analysis of pyridoxine HCl and thiamine HCl in a vitamin combination by principal component analysis, classical least squares, and inverse least squares techniques
    • Dinc, E., D. Baleanu, and F. Onur. 2001. Chemometric quantitative analysis of pyridoxine HCl and thiamine HCl in a vitamin combination by principal component analysis, classical least squares, and inverse least squares techniques. Spectrosc. Lett. 34: 279-288.
    • (2001) Spectrosc. Lett. , vol.34 , pp. 279-288
    • Dinc, E.1    Baleanu, D.2    Onur, F.3
  • 5
    • 17644435706 scopus 로고    scopus 로고
    • A comparison of matrix resolution method, ratio spectra derivative spectrophotometry, and HPLC method for the determination of thiamine HCl and pyridoxine HCl in pharmaceutical preparation
    • Dinc, E., G. Kokdil, and F. Onur. 2000. A comparison of matrix resolution method, ratio spectra derivative spectrophotometry, and HPLC method for the determination of thiamine HCl and pyridoxine HCl in pharmaceutical preparation. J. Pharm. Biomed. Anal. 22: 915-923.
    • (2000) J. Pharm. Biomed. Anal. , vol.22 , pp. 915-923
    • Dinc, E.1    Kokdil, G.2    Onur, F.3
  • 6
    • 0034997548 scopus 로고    scopus 로고
    • Multi-task flow system for potentiometric analysis: Its application to the determination of vitamin B-6 in pharmaceuticals
    • Fernandes, R. N., M. G. F. Sales, B. F. Reis, E. A. G. Zagatto, A. N. Araujo, and M. Montenegro. 2001. Multi-task flow system for potentiometric analysis: Its application to the determination of vitamin B-6 in pharmaceuticals. J. Pharm. Biomed. Anal. 25: 713-720.
    • (2001) J. Pharm. Biomed. Anal. , vol.25 , pp. 713-720
    • Fernandes, R.N.1    Sales, M.G.F.2    Reis, B.F.3    Zagatto, E.A.G.4    Araujo, A.N.5    Montenegro, M.6
  • 7
    • 34247157785 scopus 로고    scopus 로고
    • Potentiometric sensor for heparin polyion: Transient behavior and response mechanism
    • Langmaier, J., E. Samcova, and Z. Samec. 2007. Potentiometric sensor for heparin polyion: Transient behavior and response mechanism. Anal. Chem. 79: 2892-2900.
    • (2007) Anal. Chem. , vol.79 , pp. 2892-2900
    • Langmaier, J.1    Samcova, E.2    Samec, Z.3
  • 8
    • 0026300062 scopus 로고
    • Vitamins B1 and B6 tubular electrodes as FIA detectors; their use in the analysis of pharmaceutical products
    • Lima, J. L. F. C., M. C. B. S. M. Montenegro, and A. M. R. Silva. 1991. Vitamins B1 and B6 tubular electrodes as FIA detectors; their use in the analysis of pharmaceutical products. J. Pharm. Biomed. Anal. 9: 1041-1046.
    • (1991) J. Pharm. Biomed. Anal. , vol.9 , pp. 1041-1046
    • Lima, J.L.F.C.1    Montenegro, M.C.B.S.M.2    Silva, A.M.R.3
  • 9
    • 33746714965 scopus 로고    scopus 로고
    • Simultaneous determination and classification of riboflavin, thiamine, nicotinamide, and pyridoxine in pharmaceutical formulations, by UV-visible spectrophotometry and multivariate analysis
    • Lopez-de-Alba, P. L., L. Lopez-Martinez, V. Cerda, and J. Amador-Hernandez. 2006. Simultaneous determination and classification of riboflavin, thiamine, nicotinamide, and pyridoxine in pharmaceutical formulations, by UV-visible spectrophotometry and multivariate analysis. J. Brazil. Chem. Soc. 17: 715-722.
    • (2006) J. Brazil. Chem. Soc. , vol.17 , pp. 715-722
    • Lopez-de-Alba, P.L.1    Lopez-Martinez, L.2    Cerda, V.3    Amador-Hernandez, J.4
  • 10
    • 0029687987 scopus 로고    scopus 로고
    • High-resolution higher-order derivative spectrophotometry for determination of ternary mixtures of B-complex vitamins in pharmaceuticals. Fresenius
    • Morelli, B. 1996. High-resolution higher-order derivative spectrophotometry for determination of ternary mixtures of B-complex vitamins in pharmaceuticals. Fresenius J. Anal. Chem. 354: 97-102.
    • (1996) J. Anal. Chem. , vol.354 , pp. 97-102
    • Morelli, B.1
  • 11
    • 3543104412 scopus 로고    scopus 로고
    • Potentiometric membrane sensors for the selective determination of pyridoxine hydrochloride (vitamin B6) in some pharmaceutical formulations
    • Mostafa, G. A. E. 2003. Potentiometric membrane sensors for the selective determination of pyridoxine hydrochloride (vitamin B6) in some pharmaceutical formulations. J. Anal. Chem. 58: 1073-1077.
    • (2003) J. Anal. Chem. , vol.58 , pp. 1073-1077
    • Mostafa, G.A.E.1
  • 13
    • 34548490102 scopus 로고    scopus 로고
    • Conducting polymers in modelling transient potential of biological membranes
    • Paczosa-Bator, B., T. Blaz, J. Migdalski, and A. Lewenstam. 2005. Conducting polymers in modelling transient potential of biological membranes. Bioelectro-chemistry, 71: 66-74.
    • (2005) Bioelectro-chemistry , vol.71 , pp. 66-74
    • Paczosa-Bator, B.1    Blaz, T.2    Migdalski, J.3    Lewenstam, A.4
  • 14
    • 34548490102 scopus 로고    scopus 로고
    • Conducting polymers in modelling transient potential of biological membranes
    • Paczosa-Bator, B., T. Blaz, J. Migdalski, and A. Lewenstam. 2007. Conducting polymers in modelling transient potential of biological membranes. Bioelectro-chemistry, 71: 66-74.
    • (2007) Bioelectro-chemistry , vol.71 , pp. 66-74
    • Paczosa-Bator, B.1    Blaz, T.2    Migdalski, J.3    Lewenstam, A.4
  • 15
    • 39149132459 scopus 로고    scopus 로고
    • New ionophores for vitamin B1 and vitamin B6 potentiometric sensors for multivitaminic control
    • Pires, A. R., A. N. Araujo, M. Montenegro, P. Chocholous, and P. Solich. 2008. New ionophores for vitamin B1 and vitamin B6 potentiometric sensors for multivitaminic control. J. Pharm. Biomed. Anal. 46: 683-691.
    • (2008) J. Pharm. Biomed. Anal. , vol.46 , pp. 683-691
    • Pires, A.R.1    Araujo, A.N.2    Montenegro, M.3    Chocholous, P.4    Solich, P.5
  • 16
    • 0037413520 scopus 로고    scopus 로고
    • A multicommuted flow system for sequential spectrophotometric determination of hydrosoluble vitamins in pharmaceutical preparations
    • Rocha, F. R. P., O. Fatibello, and B. F. Reis. 2003. A multicommuted flow system for sequential spectrophotometric determination of hydrosoluble vitamins in pharmaceutical preparations. Talanta 59: 191-200.
    • (2003) Talanta , vol.59 , pp. 191-200
    • Rocha, F.R.P.1    Fatibello, O.2    Reis, B.F.3
  • 17
    • 2442656957 scopus 로고    scopus 로고
    • Sequential injection analysis of chloride and nitrate in waters with improved accuracy using potentiometric detection
    • Santos, E., M. Montenegro, C. Couto, A. N. Araujo, M. F. Pimentel, and V. L. da Silva. 2004. Sequential injection analysis of chloride and nitrate in waters with improved accuracy using potentiometric detection. Talanta 63: 721-727.
    • (2004) Talanta , vol.63 , pp. 721-727
    • Santos, E.1    Montenegro, M.2    Couto, C.3    Araujo, A.N.4    Pimentel, M.F.5    da Silva, V.L.6
  • 18
    • 0004206781 scopus 로고    scopus 로고
    • Secretariat, B. P. C., ed. London: HRM Stationery Office
    • Secretariat, B. P. C., ed. 2005. British Pharmacopoeia. London: HRM Stationery Office.
    • (2005) British Pharmacopoeia
  • 19
    • 33646424126 scopus 로고    scopus 로고
    • Flow-injection determination of water-soluble vitamins B1, B2, and B6 from the electrocatalytic response of a graphite electrode modified with a ruthenium(III) hexacyanoruthenate(II) film
    • Shaidarova, L. G., L. N. Davietshina, and G. K. Budnikov. 2006. Flow-injection determination of water-soluble vitamins B1, B2, and B6 from the electrocatalytic response of a graphite electrode modified with a ruthenium(III) hexacyanoruthenate(II) film. J. Anal. Chem. 61: 502-509.
    • (2006) J. Anal. Chem. , vol.61 , pp. 502-509
    • Shaidarova, L.G.1    Davietshina, L.N.2    Budnikov, G.K.3
  • 20
    • 0004074875 scopus 로고    scopus 로고
    • Sweetman, S., ed. 33rd ed. London, Great Britain: Pharmaceutical Press
    • Sweetman, S., ed. 2002. Martindale: The Complete Drug Reference, 33rd ed. London, Great Britain: Pharmaceutical Press.
    • (2002) Martindale: The Complete Drug Reference
  • 21
    • 0038718644 scopus 로고    scopus 로고
    • Determination of vitamin B-6 (pyridoxine) in pharmaceutical preparations by cyclic voltammetry at a copper(II) hexacyanoferrate(III) modified carbon paste electrode
    • Teixeira, M. F. S., A. Segnini, F. C. Moraes, L. H. Marcolino, O. Fatibello, and E. T. G. Cavalheiro. 2003. Determination of vitamin B-6 (pyridoxine) in pharmaceutical preparations by cyclic voltammetry at a copper(II) hexacyanoferrate(III) modified carbon paste electrode. J. Brazil. Chem. Soc. 14: 316-321.
    • (2003) J. Brazil. Chem. Soc. , vol.14 , pp. 316-321
    • Teixeira, M.F.S.1    Segnini, A.2    Moraes, F.C.3    Marcolino, L.H.4    Fatibello, O.5    Cavalheiro, E.T.G.6
  • 23
    • 0000189043 scopus 로고
    • Vitamin B1 sensitive poly(vinyl chloride) membrane-electrode based on hydrophobic tetraphenylborate derivatives and their application
    • Zhang, G. H., T. Imato, Y. Asano, T. Sonoda, H. Kobayashi, and N. Ishibashi. 1990. Vitamin B1 sensitive poly(vinyl chloride) membrane-electrode based on hydrophobic tetraphenylborate derivatives and their application. Anal. Chem. 62: 1644-1648.
    • (1990) Anal. Chem. , vol.62 , pp. 1644-1648
    • Zhang, G.H.1    Imato, T.2    Asano, Y.3    Sonoda, T.4    Kobayashi, H.5    Ishibashi, N.6
  • 24
    • 0025180641 scopus 로고
    • Sensitive membrane electrodes for determination of vitamin B1 and vitamin B6
    • Zhang, Z. R., Y. X. Li, D. Y. Mao, and V. V. Cosofret. 1990. Sensitive membrane electrodes for determination of vitamin B1 and vitamin B6. J. Pharm. Biomed. Anal. 8: 385-388.
    • (1990) J. Pharm. Biomed. Anal. , vol.8 , pp. 385-388
    • Zhang, Z.R.1    Li, Y.X.2    Mao, D.Y.3    Cosofret, V.V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.