메뉴 건너뛰기




Volumn , Issue , 2009, Pages

Shear sensor for lower limb prosthetic applications

Author keywords

[No Author keywords available]

Indexed keywords

LOWER LIMB; LOWER-LIMB AMPUTEES; PROSTHETIC DEVICES; SENSOR DESIGNS; SHEAR SENSOR; SHEAR-STRESS SENSORS; SKIN INJURIES; TEST RESULTS;

EID: 70349996296     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BSEC.2009.5090469     Document Type: Conference Paper
Times cited : (12)

References (11)
  • 2
    • 0032276747 scopus 로고    scopus 로고
    • Z. Ming, A. F. T. Mak, A. I. K. Chung, and K. H. Chung, MRI Investigation of Musculoskeletal Action of Transfemoral Residual Limb Inside a Prosthetic Socket, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 5, 1998, pp. 2741-2743.
    • Z. Ming, A. F. T. Mak, A. I. K. Chung, and K. H. Chung, "MRI Investigation of Musculoskeletal Action of Transfemoral Residual Limb Inside a Prosthetic Socket," Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, vol. 5, 1998, pp. 2741-2743.
  • 3
    • 70349990276 scopus 로고    scopus 로고
    • J. Engel, J. Chen, C. Liu, B. R. Flachsbart, J. C. Selby, and M. A. Shannon, Development of Polyimide-Based Flexible Tactile Sensing Skin, Materials Research Society Symposium, 736, 2003, pp. D4.5.2-D4.5.6.
    • J. Engel, J. Chen, C. Liu, B. R. Flachsbart, J. C. Selby, and M. A. Shannon, "Development of Polyimide-Based Flexible Tactile Sensing Skin," Materials Research Society Symposium, vol. 736, 2003, pp. D4.5.2-D4.5.6.
  • 5
    • 1542360826 scopus 로고    scopus 로고
    • Novel Sensor Technology for Shear and Normal Strain Detection With Generalized Electrostriction
    • T. R. Filanc-Bowen, H. K. Geun, and Y. M. Shkel, "Novel Sensor Technology for Shear and Normal Strain Detection With Generalized Electrostriction," Proceedings of IEEE Sensors, vol. 2, 2002, pp. 1648-1653.
    • (2002) Proceedings of IEEE Sensors , vol.2 , pp. 1648-1653
    • Filanc-Bowen, T.R.1    Geun, H.K.2    Shkel, Y.M.3
  • 9
    • 38749110719 scopus 로고    scopus 로고
    • Temporal Characteristics of Plantar Shear Distribution: Relevance to Diabetic Patients
    • M. Yavuz, A. Tajaddini, G. Botek, and B. L. Davis, "Temporal Characteristics of Plantar Shear Distribution: Relevance to Diabetic Patients," Journal of Biomechanics, vol. 41, no. 3, pp. 556-559, 2008.
    • (2008) Journal of Biomechanics , vol.41 , Issue.3 , pp. 556-559
    • Yavuz, M.1    Tajaddini, A.2    Botek, G.3    Davis, B.L.4
  • 10
    • 23944432418 scopus 로고    scopus 로고
    • A Theoretical Description of Elastic Pillar Substrates in Biophysical Experiments
    • Aug
    • C. Mohrdieck, A. Wanner, W. Roos, A. Roth, E. Sackmann, J. P. Spatz, and E. Arzt, "A Theoretical Description of Elastic Pillar Substrates in Biophysical Experiments," Chemphyschem, vol. 6, no. 8, pp. 1492-1498, Aug. 2005.
    • (2005) Chemphyschem , vol.6 , Issue.8 , pp. 1492-1498
    • Mohrdieck, C.1    Wanner, A.2    Roos, W.3    Roth, A.4    Sackmann, E.5    Spatz, J.P.6    Arzt, E.7
  • 11
    • 5444242577 scopus 로고    scopus 로고
    • G. I. Rowe and A. V. Mamishev, Simulation of a Sensor Array for Multiparameter Measurements at the Prosthetic Limb Interface, Health Monitoring and Smart Nondestructive Evaluation of Structural and Biological Systems III, 5394, 7-21-2004, pp. 493-500.
    • G. I. Rowe and A. V. Mamishev, "Simulation of a Sensor Array for Multiparameter Measurements at the Prosthetic Limb Interface," Health Monitoring and Smart Nondestructive Evaluation of Structural and Biological Systems III, vol. 5394, 7-21-2004, pp. 493-500.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.