메뉴 건너뛰기




Volumn 111, Issue 4, 2009, Pages 840-844

Failure rate of contemporary low-dose radiosurgical technique for vestibular schwannoma: Clinical article

Author keywords

Acoustic neuroma; Dosimetry; Radiosurgery; Vestibular schwannoma

Indexed keywords

ADULT; AGED; ARTICLE; CRANIAL NERVE; FEMALE; FOLLOW UP; GAMMA KNIFE RADIOSURGERY; HUMAN; MAJOR CLINICAL STUDY; MALE; MORBIDITY; NEURILEMOMA; NUCLEAR MAGNETIC RESONANCE IMAGING; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RADIATION DOSE; RETROSPECTIVE STUDY; SURGICAL TECHNIQUE; TREATMENT FAILURE; TUMOR GROWTH; TUMOR VOLUME; VESTIBULAR SCHWANNOMA;

EID: 70349925729     PISSN: 00223085     EISSN: 19330693     Source Type: Journal    
DOI: 10.3171/2009.3.JNS08949     Document Type: Article
Times cited : (63)

References (25)
  • 1
    • 44849102680 scopus 로고    scopus 로고
    • Comparison of the surgical and follow-up costs associated with microsurgical resection and stereotactic radiosurgery for vestibular schwannoma
    • DOI 10.3171/JNS/2008/108/6/1220
    • Banerjee R, Moriarty J, Foote RL, Pollock BE: Comparison of the surgical and follow-up costs associated with microsurgical resection and stereotactic radiosurgery for vestibular schwannoma. J Neurosurg 108:1220-1224, 2008 (Pubitemid 351798500)
    • (2008) Journal of Neurosurgery , vol.108 , Issue.6 , pp. 1220-1224
    • Banerjee, R.1    Moriarty, J.P.2    Foote, R.L.3    Pollock, B.E.4
  • 2
    • 0036894589 scopus 로고    scopus 로고
    • Effect of subpixel magnetic resonance imaging shifts on radiosurgical dosimetry for vestibular schwannoma
    • Borden JA, Tsai J, Mahajan A: Effect of subpixel magnetic resonance imaging shifts on radiosurgical dosimetry for vestibular schwannoma. J Neurosurg 97 (5 Suppl):445-449, 2002 (Pubitemid 35424322)
    • (2002) Journal of Neurosurgery , vol.97 , Issue.SUPPL. 5 , pp. 445-449
    • Borden, J.A.1    Tsai, J.-S.2    Mahajan, A.3
  • 3
    • 0029909858 scopus 로고    scopus 로고
    • MRI distortion and stereotactic neurosurgery using the Cosman-Roberts-Wells and Leksell frames
    • Burchiel KJ, Nguyen TT, Coombs BD, Szumoski J: MRI distortion and stereotactic neurosurgery using the Cosman-Roberts-Wells and Leksell frames. Stereotact Funct Neurosurg 66:123-136, 1996
    • (1996) Stereotact Funct Neurosurg , vol.66 , pp. 123-136
    • Burchiel, K.J.1    Nguyen, T.T.2    Coombs, B.D.3    Szumoski, J.4
  • 7
    • 23244465370 scopus 로고    scopus 로고
    • Stereotactic radiosurgery for vestibular schwannomas: Analysis of 317 patients followed more than 5 years
    • DOI 10.1227/01.NEU.0000166542.00512.84
    • Hasegawa T, Fujitani S, Katsumata S, Kida Y, Yoshimoto M, Koike J: Stereotactic radiosurgery for vestibular schwannomas: analysis of 317 patients followed more than 5 years. Neurosurgery 57:257-264, 2005 (Pubitemid 41098691)
    • (2005) Neurosurgery , vol.57 , Issue.2 , pp. 257-263
    • Hasegawa, T.1    Fujitani, S.2    Katsumata, S.3    Kida, Y.4    Yoshimoto, M.5    Koike, J.6
  • 10
    • 0026652757 scopus 로고
    • A comparison between magnetic resonance imaging and compued tomography for stereotactic coordinate determination
    • Kondziolka D, Dempsey PK, Lunsford LD, Kestle JR, Dolan EJ, Kanal E, et al: A comparison between magnetic resonance imaging and compued tomography for stereotactic coordinate determination. Neurosurgery 30:402-406, 1992
    • (1992) Neurosurgery , vol.30 , pp. 402-406
    • Kondziolka, D.1    Dempsey, P.K.2    Lunsford, L.D.3    Kestle, J.R.4    Dolan, E.J.5    Kanal, E.6
  • 12
    • 34548665085 scopus 로고    scopus 로고
    • The Leksell Gamma Knife Perfexion and comparisons with its predecessors
    • DOI 10.1227/01.neu.0000289726.35330.8a, PII 0000612320070900100022
    • Lindquist C, Paddick I: The Leksell Gamma Knife Perfexion and comparisons with its predecessors. Neurosurgery 61 (3 Suppl):130-140, 2007 (Pubitemid 47417642)
    • (2007) Neurosurgery , vol.61 , Issue.3 SUPPL.
    • Lindquist, C.1    Paddick, I.2
  • 14
  • 15
    • 18244368725 scopus 로고    scopus 로고
    • Vestibular schwannomas: Clinical results and quality of life after microsurgery or gamma knife radiosurgery
    • DOI 10.1227/01.NEU.0000158315.64079.0A
    • Myrseth E, Moller P, Pedersen P, Vassbotn FS, Wentzel-Larsen T, Lund-Johansen M: Vestibular schwannomas: clinical results and quality of life after microsurgery or gamma knife radiosurgery. Neurosurgery 56:927-935, 2005 (Pubitemid 40628084)
    • (2005) Neurosurgery , vol.56 , Issue.5 , pp. 927-934
    • Myrseth, E.1    Moller, P.2    Pedersen, P.-H.3    Vassbotn, F.S.4    Wentzel-Larsen, T.5    Lund-Johansen, M.6
  • 16
    • 0032879324 scopus 로고    scopus 로고
    • Dose reduction improves hearing preservation rates after intracanalicular acoustic tumor radiosurgery
    • Niranjan A, Lunsford LD: Flickinger, Maitz A, Kondziolka D: Dose reduction improves hearing preservation rates after intracanalicular acoustic tumor radiosurgery. Neurosurgery 45:753-762, 1999
    • (1999) Neurosurgery , vol.45 , pp. 753-762
    • Niranjan, A.1    Lunsford, L.D.2    Flickinger3    Maitz, A.4    Kondziolka, D.5
  • 18
    • 32244437787 scopus 로고    scopus 로고
    • Management of vestibular schwannomas that enlarge after stereotactic radiosurgery: Treatment recommendations based on a 15-year experience
    • Pollock BE: Management of vestibular schwannomas that enlarge after stereotactic radiosurgery: treatment recommendations based on a 15-year experience. Neurosurgery 58:241-247, 2006
    • (2006) Neurosurgery , vol.58 , pp. 241-247
    • Pollock, B.E.1
  • 19
    • 33745793459 scopus 로고    scopus 로고
    • Patient outcomes after vestibular schwannoma management: A prospective comparison of microsurgical resection and stereotactic radiosurgery
    • Pollock BE, Driscoll CLW, Foote RL, Link MJ, Gorman DA, Bauch CD, et al: Patient outcomes after vestibular schwannoma management: a prospective comparison of microsurgical resection and stereotactic radiosurgery. Neurosurgery 59:77-85, 2006
    • (2006) Neurosurgery , vol.59 , pp. 77-85
    • Pollock, B.E.1    Driscoll, C.L.W.2    Foote, R.L.3    Link, M.J.4    Gorman, D.A.5    Bauch, C.D.6
  • 21
    • 0036894787 scopus 로고    scopus 로고
    • Impact of the model C and Automatic Positioning System on gamma knife radiosurgery: An evaluation in vestibular schwannomas
    • Régis J, Hayashi M, Porcheron D, Delsanti C, Muracciole X, et al: Impact of the model C and Automatic Postioning System on Gamma Knife radiosurgery: an evaluation in vestibular schwannomas. J Neurosurg 97 (5 Suppl):588-591, 2002 (Pubitemid 35424351)
    • (2002) Journal of Neurosurgery , vol.97 , Issue.SUPPL. 5 , pp. 588-591
    • Regis, J.1    Hayashi, M.2    Porcheron, D.3    Delsanti, C.4    Muracciole, X.5    Peragut, J.C.6
  • 24
    • 0030923738 scopus 로고    scopus 로고
    • Stereotactic localization with magnetic resonance imaging: A phantom study to compare the accuracy obtained using two-dimensional and three- Dimensional data acquisitions
    • DOI 10.1097/00006123-199707000-00027
    • Walton L, Hampshire A, Forster DM, Kemeny AA: Stereotactic localization with magnetic resonance imaging: a phantom study to compare accuracy obtained using two-dimensional and three-dimensional data acquisitions. Neurosurgery 41:131-137, 1997 (Pubitemid 27282091)
    • (1997) Neurosurgery , vol.41 , Issue.1 , pp. 131-139
    • Walton, L.1    Hampshire, A.2    Forster, D.M.C.3    Kemeny, A.A.4
  • 25
    • 0035056150 scopus 로고    scopus 로고
    • A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system
    • Yu C, Apuzzo ML, Zee CS, Petrovich Z: A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system. Neurosurgery 48:1092-1098, 2001 (Pubitemid 32336604)
    • (2001) Neurosurgery , vol.48 , Issue.5 , pp. 1092-1099
    • Yu, C.1    Apuzzo, M.L.J.2    Zee, C.-S.3    Petrovich, Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.