메뉴 건너뛰기




Volumn 19, Issue 10, 2009, Pages 2407-2415

Management strategies for thoracic stent-graft repair of distal aortic arch lesions: Is intentional subclavian artery occlusion a safe procedure?

Author keywords

Aorta; Aortic dissection; Stent graft; Thoracic aneurysm

Indexed keywords

ADULT; AGED; AORTA ARCH; ARM WEAKNESS; ARTERY GRAFT; ARTERY OCCLUSION; ARTICLE; BLOOD VESSEL INJURY; CLINICAL ARTICLE; COIL EMBOLIZATION; CONTROLLED STUDY; ENDOLEAK; ENDOVASCULAR SURGERY; FEMALE; GRAFT PATENCY; HAND PARESTHESIA; HUMAN; MALE; MEAN ARTERIAL PRESSURE; MORTALITY; PARAPLEGIA; PATIENT SAFETY; PERIOPERATIVE COMPLICATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; STENT; SUBCLAVIAN ARTERY; SURGICAL TECHNIQUE; SURVIVAL RATE; THORACIC AORTA ANEURYSM; VISUAL IMPAIRMENT;

EID: 70349883874     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-009-1433-3     Document Type: Article
Times cited : (12)

References (27)
  • 1
    • 0141741417 scopus 로고    scopus 로고
    • Descending thoracic aortic diseases: Stent-graft repair
    • Fattori R, Napoli G, Lovato L et al (2003) Descending thoracic aortic diseases: Stent-graft repair. Radiology 229:176-183
    • (2003) Radiology , vol.229 , pp. 176-183
    • Fattori, R.1    Napoli, G.2    Lovato, L.3
  • 2
    • 0141534252 scopus 로고    scopus 로고
    • Left subclavian artery management in endovascular repair of thoracic aortic aneurysms and aortic dissections
    • Tiesenhausen K, Hausegger KA, Oberwalder P et al (2003) Left subclavian artery management in endovascular repair of thoracic aortic aneurysms and aortic dissections. J Card Surg 18:429-435
    • (2003) J Card Surg , vol.18 , pp. 429-435
    • Tiesenhausen, K.1    Hausegger, K.A.2    Oberwalder, P.3
  • 3
    • 12144282738 scopus 로고    scopus 로고
    • Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: Risk and relevance
    • Rehders TC, Petzsch M, Ince H et al (2004) Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: Risk and relevance. J Endovasc Ther 11:659-666
    • (2004) J Endovasc Ther , vol.11 , pp. 659-666
    • Rehders, T.C.1    Petzsch, M.2    Ince, H.3
  • 4
    • 0036616575 scopus 로고    scopus 로고
    • Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs
    • Görich J, Asquan Y, Seifarth H et al (2002) Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther 9:39-43
    • (2002) J Endovasc Ther , vol.9 , pp. 39-43
    • Görich, J.1    Asquan, Y.2    Seifarth, H.3
  • 5
    • 0036205069 scopus 로고    scopus 로고
    • Self-expandable aortic stent-grafts for treatment of descending aortic dissections
    • Palma JH, De Souza JA, Rodrigues Alves CM et al (2002) Self-expandable aortic stent-grafts for treatment of descending aortic dissections. Ann Thorac Surg 73:1138-1142
    • (2002) Ann Thorac Surg , vol.73 , pp. 1138-1142
    • Palma, J.H.1    De Souza, J.A.2    Rodrigues Alves, C.M.3
  • 6
    • 56249095126 scopus 로고    scopus 로고
    • Treatment of type II endoleaks associated with left subclavian artery coverage during thoracic aortic stent grafting
    • Peterson MD, Wheatley GH 3rd, Kpodonu J et al (2008) Treatment of type II endoleaks associated with left subclavian artery coverage during thoracic aortic stent grafting. J Thorac Cardiovasc Surg 136:1193-1199
    • (2008) J Thorac Cardiovasc Surg , vol.136 , pp. 1193-1199
    • Peterson, M.D.1    Wheatley III, G.H.2    Kpodonu, J.3
  • 7
    • 33845930018 scopus 로고    scopus 로고
    • Coverage of the left subclavian artery during thoracic endovascular aortic repair
    • Riesenman PJ, Farber MA, Mendes RR et al (2007) Coverage of the left subclavian artery during thoracic endovascular aortic repair. J Vasc Surg 45:90-94
    • (2007) J Vasc Surg , vol.45 , pp. 90-94
    • Riesenman, P.J.1    Farber, M.A.2    Mendes, R.R.3
  • 8
    • 33744769140 scopus 로고    scopus 로고
    • Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease
    • Caronno R, Piffaretti G, Tozzi M et al (2006) Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease. Surg Endosc 20:915-918
    • (2006) Surg Endosc , vol.20 , pp. 915-918
    • Caronno, R.1    Piffaretti, G.2    Tozzi, M.3
  • 9
    • 1842682038 scopus 로고    scopus 로고
    • In situ stent-graft fenestration to preserve the left subclavian artery
    • McWilliams RG, Murphy M, Hartley D et al (2004) In situ stent-graft fenestration to preserve the left subclavian artery. J Endovasc Ther 11:170-174
    • (2004) J Endovasc Ther , vol.11 , pp. 170-174
    • McWilliams, R.G.1    Murphy, M.2    Hartley, D.3
  • 10
    • 14844302849 scopus 로고    scopus 로고
    • Feasibility of the Inoue single-branched stent-graft implantation for thoracic aortic aneurysm or dissection involving the left subclavian artery: Short to medium term results in 17 patients
    • Saito N, Kimura T, Odashiro K et al (2005) Feasibility of the Inoue single-branched stent-graft implantation for thoracic aortic aneurysm or dissection involving the left subclavian artery: Short to medium term results in 17 patients. J Vasc Surg 41:206-212
    • (2005) J Vasc Surg , vol.41 , pp. 206-212
    • Saito, N.1    Kimura, T.2    Odashiro, K.3
  • 11
    • 0141919793 scopus 로고    scopus 로고
    • Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection
    • Chuter TA, Schneider DB, Reilly LM et al (2003) Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection. J Vasc Surg 38:859-863
    • (2003) J Vasc Surg , vol.38 , pp. 859-863
    • Chuter, T.A.1    Schneider, D.B.2    Reilly, L.M.3
  • 12
    • 1942499733 scopus 로고    scopus 로고
    • Endovascular grafting of complex aortic aneurysms with a modular side branch stent-graft system in porcine model
    • Vos AW, Linsen MA, Wisselink W et al (2004) Endovascular grafting of complex aortic aneurysms with a modular side branch stent-graft system in porcine model. Eur J Vasc Endovasc Surg 27:492-497
    • (2004) Eur J Vasc Endovasc Surg , vol.27 , pp. 492-497
    • Vos, A.W.1    Linsen, M.A.2    Wisselink, W.3
  • 13
    • 35848954306 scopus 로고    scopus 로고
    • Early results of endovascular treatment of the thoracic aorta using the Valiant endograft
    • Thompson M, Ivaz S, Cheshire N et al (2007) Early results of endovascular treatment of the thoracic aorta using the Valiant endograft. Cardiovasc Intervent Radiol 30:1130-1138
    • (2007) Cardiovasc Intervent Radiol , vol.30 , pp. 1130-1138
    • Thompson, M.1    Ivaz, S.2    Cheshire, N.3
  • 14
    • 33644698598 scopus 로고    scopus 로고
    • Utility of the left subclavian artery revascularization in association with endoluminal repair of acute and chronic thoracic aortic pathology
    • Peterson BG, Eskandari MK, Gleason TG et al (2006) Utility of the left subclavian artery revascularization in association with endoluminal repair of acute and chronic thoracic aortic pathology. J Vasc Surg 43:433-439
    • (2006) J Vasc Surg , vol.43 , pp. 433-439
    • Peterson, B.G.1    Eskandari, M.K.2    Gleason, T.G.3
  • 15
    • 37249091708 scopus 로고    scopus 로고
    • Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. a study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) registry
    • Buth J, Harris PL, Hobo R et al (2007) Neurologic complications associated with endovascular repair of thoracic aortic pathology: incidence and risk factors. a study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) registry. J Vasc Surg 46:1103-1110
    • (2007) J Vasc Surg , vol.46 , pp. 1103-1110
    • Buth, J.1    Harris, P.L.2    Hobo, R.3
  • 16
    • 49249099978 scopus 로고    scopus 로고
    • Is it safe to cover the left subclavian artery when placing an endovascular stent in the descending thoracic aorta?
    • Dunning J, Martin JE, Shennib H et al (2008) Is it safe to cover the left subclavian artery when placing an endovascular stent in the descending thoracic aorta? Interact Cardiovasc Thorac Surg 7:690-697
    • (2008) Interact Cardiovasc Thorac Surg , vol.7 , pp. 690-697
    • Dunning, J.1    Martin, J.E.2    Shennib, H.3
  • 17
    • 49749116773 scopus 로고    scopus 로고
    • Left subclavian artery coverage during thoracic endovascular aortic repair: A single-center experience
    • Woo EY, Carpenter JP, Jackson BM et al (2008) Left subclavian artery coverage during thoracic endovascular aortic repair: A single-center experience. J Vasc Surg 48:555-560
    • (2008) J Vasc Surg , vol.48 , pp. 555-560
    • Woo, E.Y.1    Carpenter, J.P.2    Jackson, B.M.3
  • 18
    • 0036517480 scopus 로고    scopus 로고
    • Subclavian carotid transposition and bypass grafting: Consecutive cohort study and systematic review
    • Cina CS, Safar HA, Laganà A et al (2002) Subclavian carotid transposition and bypass grafting: Consecutive cohort study and systematic review. J Vasc Surg 35:422-429
    • (2002) J Vasc Surg , vol.35 , pp. 422-429
    • Cina, C.S.1    Safar, H.A.2    Laganà, A.3
  • 19
    • 56349091015 scopus 로고    scopus 로고
    • Two-year single-center experience with thoracic endovascular aortic repair using the EndoFit thoracic stent-graft
    • Qu L, Raithel D (2008) Two-year single-center experience with thoracic endovascular aortic repair using the EndoFit thoracic stent-graft. J Endovasc Ther 15:530-538
    • (2008) J Endovasc Ther , vol.15 , pp. 530-538
    • Qu, L.1    Raithel, D.2
  • 20
    • 0031739777 scopus 로고    scopus 로고
    • The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta
    • Dake MD, Miller DC, Mitchell RS et al (1998) The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta. J Thorac Cardiovasc Surg 116:689-704
    • (1998) J Thorac Cardiovasc Surg , vol.116 , pp. 689-704
    • Dake, M.D.1    Miller, D.C.2    Mitchell, R.S.3
  • 21
    • 31044436401 scopus 로고    scopus 로고
    • Endovascular repair of the thoracic aorta necessitating anchoring of the stent graft across the arch vessels
    • Schoder M, Grabenwoger M, Hölzenbein T et al (2006) Endovascular repair of the thoracic aorta necessitating anchoring of the stent graft across the arch vessels. J Thorac Cardiovasc Surg 131:380-387
    • (2006) J Thorac Cardiovasc Surg , vol.131 , pp. 380-387
    • Schoder, M.1    Grabenwoger, M.2    Hölzenbein, T.3
  • 22
    • 0032125753 scopus 로고    scopus 로고
    • Endovascular stent graft repair for aneurysms on the descending thoracic aorta
    • Ehrlich M, Grabenwoeger M, Cartes-Zumelzu F et al (1998) Endovascular stent graft repair for aneurysms on the descending thoracic aorta. Ann Thorac Surg 66:19-25
    • (1998) Ann Thorac Surg , vol.66 , pp. 19-25
    • Ehrlich, M.1    Grabenwoeger, M.2    Cartes-Zumelzu, F.3
  • 23
    • 0342879933 scopus 로고    scopus 로고
    • Thoracic aortic aneurysms: Treatment with endovascular self-expandable stent grafts
    • Grabenwoger M, Hutschala D, Ehrlich MP et al (2000) Thoracic aortic aneurysms: Treatment with endovascular self-expandable stent grafts. Ann Thorac Surg 69:441-445
    • (2000) Ann Thorac Surg , vol.69 , pp. 441-445
    • Grabenwoger, M.1    Hutschala, D.2    Ehrlich, M.P.3
  • 24
    • 17144443595 scopus 로고    scopus 로고
    • Aortic arch reconstruction by transluminally placed endovascular branched stent-graft
    • Inoue K, Hosokawa H, Iwase T et al (1999) Aortic arch reconstruction by transluminally placed endovascular branched stent-graft. Circulation 2:316-321
    • (1999) Circulation , vol.2 , pp. 316-321
    • Inoue, K.1    Hosokawa, H.2    Iwase, T.3
  • 25
    • 42649126047 scopus 로고    scopus 로고
    • Management of left subclavian artery in endovascular stent-grafting for distal aortic arch disease
    • Kurimoto Y, Ito T, Harada R et al (2008) Management of left subclavian artery in endovascular stent-grafting for distal aortic arch disease. Circ J 72:449-453
    • (2008) Circ J , vol.72 , pp. 449-453
    • Kurimoto, Y.1    Ito, T.2    Harada, R.3
  • 26
    • 33847222497 scopus 로고    scopus 로고
    • A percutaneous technique for preservation of arch branch patency during thoracic endovascular aortic repair (TEVAR): Retrograde catheterization and stenting
    • Criado FJ (2007) A percutaneous technique for preservation of arch branch patency during thoracic endovascular aortic repair (TEVAR): retrograde catheterization and stenting. J Endovasc Ther 14:54-58
    • (2007) J Endovasc Ther , vol.14 , pp. 54-58
    • Criado, F.J.1
  • 27
    • 49449103377 scopus 로고    scopus 로고
    • The chimney graft: A technique for preserving or rescuing aortic branch vessels in stent-graft sealing zones
    • Ohrlander T, Sonesson B, Ivancev K et al (2008) The chimney graft: A technique for preserving or rescuing aortic branch vessels in stent-graft sealing zones. J Endovasc Ther 15:427-432
    • (2008) J Endovasc Ther , vol.15 , pp. 427-432
    • Ohrlander, T.1    Sonesson, B.2    Ivancev, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.