메뉴 건너뛰기




Volumn 27, Issue 9, 2009, Pages 1271-1280

MAgnitude and PHase Thresholding (MAPHT) of noisy complex-valued magnetic resonance images

Author keywords

Complex; Magnitude; Phase; SWI; Threshold

Indexed keywords

ARTICLE; CONTRAST ENHANCEMENT; CONTROLLED STUDY; DIAGNOSTIC PROCEDURE; IMAGE PROCESSING; MEASUREMENT; MONTE CARLO METHOD; NOISE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SAMPLE; SIGNAL PROCESSING;

EID: 70349835785     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2009.05.008     Document Type: Article
Times cited : (4)

References (11)
  • 1
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman R.M. Measurement of signal intensities in the presence of noise in MR images. Med Phys 12 (1985) 232-233
    • (1985) Med Phys , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 2
    • 0024394344 scopus 로고
    • Improved detectability in low signal-to-noise ratio magnetic resonance images by means of phase corrected real reconstruction
    • Bernstein M.A., Thomasson D.M., and Perman W.H. Improved detectability in low signal-to-noise ratio magnetic resonance images by means of phase corrected real reconstruction. Med Phys 16 (1989) 813-817
    • (1989) Med Phys , vol.16 , pp. 813-817
    • Bernstein, M.A.1    Thomasson, D.M.2    Perman, W.H.3
  • 4
    • 33845400355 scopus 로고    scopus 로고
    • Signal and noise of Fourier reconstructed fMRI data
    • Rowe D.B., Nencka A.S., and Hoffmann R.G. Signal and noise of Fourier reconstructed fMRI data. J Neurosci Methods 159 (2007) 361-369
    • (2007) J Neurosci Methods , vol.159 , pp. 361-369
    • Rowe, D.B.1    Nencka, A.S.2    Hoffmann, R.G.3
  • 5
    • 51449113619 scopus 로고    scopus 로고
    • A complex threshold method for identifying pixels that contain predominantly noise in magnetic resonance images
    • Pandian D., Ciulla C., Haacke E.M., Jiang J., and Ayaz M. A complex threshold method for identifying pixels that contain predominantly noise in magnetic resonance images. J Magn Reson Imaging 28 (2008) 727-735
    • (2008) J Magn Reson Imaging , vol.28 , pp. 727-735
    • Pandian, D.1    Ciulla, C.2    Haacke, E.M.3    Jiang, J.4    Ayaz, M.5
  • 9
    • 1942425117 scopus 로고    scopus 로고
    • An evaluation of thresholding techniques in fMRI analysis
    • Logan B.R., and Rowe D.B. An evaluation of thresholding techniques in fMRI analysis. NeuroImage 22 (2004) 95-108
    • (2004) NeuroImage , vol.22 , pp. 95-108
    • Logan, B.R.1    Rowe, D.B.2
  • 10
    • 57149096884 scopus 로고    scopus 로고
    • An evaluation of spatial thresholding techniques in fMRI analysis
    • Logan B.R., Geliazcova M.P., and Rowe D.B. An evaluation of spatial thresholding techniques in fMRI analysis. Hum Brain Mapp 29 (2008) 1379-1389
    • (2008) Hum Brain Mapp , vol.29 , pp. 1379-1389
    • Logan, B.R.1    Geliazcova, M.P.2    Rowe, D.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.