메뉴 건너뛰기




Volumn 18, Issue 6, 2009, Pages 886-891

Optimal rotation and screw positioning for initial glenosphere baseplate fixation in reverse shoulder arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BONE SCREW; HUMAN; LONGEVITY; PRIORITY JOURNAL; REVERSE SHOULDER ARTHROPLASTY; ROTATION; SCAPULA;

EID: 70349824092     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2008.11.002     Document Type: Article
Times cited : (44)

References (22)
  • 1
    • 4544287249 scopus 로고    scopus 로고
    • Analysis of glenoid fixation for a reversed anatomy fixed-fulcrum shoulder replacement
    • Ahir S.P., Walker P.S., Squire-Taylor C.J., Blunn G.W., and Bayley J.I. Analysis of glenoid fixation for a reversed anatomy fixed-fulcrum shoulder replacement. J Biomech 37 (2004) 1699-1708
    • (2004) J Biomech , vol.37 , pp. 1699-1708
    • Ahir, S.P.1    Walker, P.S.2    Squire-Taylor, C.J.3    Blunn, G.W.4    Bayley, J.I.5
  • 2
    • 33748416019 scopus 로고    scopus 로고
    • Neer Award 2005: The Grammont reverse shoulder prosthesis: results in cuff tear arthritis, fracture sequelae, and revision arthroplasty
    • Boileau P., Watkinson D., Hatzidakis A.M., and Hovorka I. Neer Award 2005: The Grammont reverse shoulder prosthesis: results in cuff tear arthritis, fracture sequelae, and revision arthroplasty. J Shoulder Elbow Surg 15 (2006) 527-540
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 527-540
    • Boileau, P.1    Watkinson, D.2    Hatzidakis, A.M.3    Hovorka, I.4
  • 4
    • 34247587596 scopus 로고    scopus 로고
    • Locations for screw fixation beyond the glenoid vault for fixation of glenoid implants into the scapula: an anatomic study
    • Codsi M.J., Bennetts C., Powell K., and Iannotti J.P. Locations for screw fixation beyond the glenoid vault for fixation of glenoid implants into the scapula: an anatomic study. J Shoulder Elbow Surg 16 (2007) S84-S89
    • (2007) J Shoulder Elbow Surg , vol.16
    • Codsi, M.J.1    Bennetts, C.2    Powell, K.3    Iannotti, J.P.4
  • 5
    • 42749092668 scopus 로고    scopus 로고
    • The effect of screw position on the initial fixation of a reverse total shoulder prosthesis in a glenoid with a cavitary bone defect
    • Codsi M.J., and Iannotti J.P. The effect of screw position on the initial fixation of a reverse total shoulder prosthesis in a glenoid with a cavitary bone defect. J Shoulder Elbow Surg 17 (2008) 479-486
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 479-486
    • Codsi, M.J.1    Iannotti, J.P.2
  • 6
    • 23044470389 scopus 로고    scopus 로고
    • The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients
    • Frankle M., Siegal S., Pupello D., Saleem A., Mighell M., and Vasey M. The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients. J Bone Joint Surg Am 87 (2005) 1697-1705
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1697-1705
    • Frankle, M.1    Siegal, S.2    Pupello, D.3    Saleem, A.4    Mighell, M.5    Vasey, M.6
  • 7
    • 33646477698 scopus 로고    scopus 로고
    • Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques
    • Fulkerson E., Egol K.A., Kubiak E.N., Liporace F., Kummer F.J., and Koval K.J. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma 60 (2006) 830-835
    • (2006) J Trauma , vol.60 , pp. 830-835
    • Fulkerson, E.1    Egol, K.A.2    Kubiak, E.N.3    Liporace, F.4    Kummer, F.J.5    Koval, K.J.6
  • 8
    • 33746864860 scopus 로고    scopus 로고
    • Reverse total shoulder arthroplasty. Survivorship analysis of eighty replacements followed for five to ten years
    • Guery J., Favard L., Sirveaux F., Oudet D., Mole D., and Walch G. Reverse total shoulder arthroplasty. Survivorship analysis of eighty replacements followed for five to ten years. J Bone Joint Surg Am 88 (2006) 1742-1747
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 1742-1747
    • Guery, J.1    Favard, L.2    Sirveaux, F.3    Oudet, D.4    Mole, D.5    Walch, G.6
  • 9
    • 34247566503 scopus 로고    scopus 로고
    • Biomechanical comparison of component position and hardware failure in the reverse shoulder prosthesis
    • Gutiérrez S., Greiwe R.M., Frankle M.A., Siegal S., and Lee III W.E. Biomechanical comparison of component position and hardware failure in the reverse shoulder prosthesis. J Shoulder Elbow Surg 16 (2007) S9-S12
    • (2007) J Shoulder Elbow Surg , vol.16
    • Gutiérrez, S.1    Greiwe, R.M.2    Frankle, M.A.3    Siegal, S.4    Lee III, W.E.5
  • 10
    • 13844313106 scopus 로고    scopus 로고
    • Initial glenoid component fixation in "reverse" total shoulder arthroplasty: a biomechanical evaluation
    • Harman M., Frankle M., Vasey M., and Banks S. Initial glenoid component fixation in "reverse" total shoulder arthroplasty: a biomechanical evaluation. J Shoulder Elbow Surg 14 (2005) 162S-167S
    • (2005) J Shoulder Elbow Surg , vol.14
    • Harman, M.1    Frankle, M.2    Vasey, M.3    Banks, S.4
  • 11
    • 0037228899 scopus 로고    scopus 로고
    • Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws
    • Hitchon P.W., Brenton M.D., Coppes J.K., From A.M., and Torner J.C. Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws. Spine 28 (2003) 9-13
    • (2003) Spine , vol.28 , pp. 9-13
    • Hitchon, P.W.1    Brenton, M.D.2    Coppes, J.K.3    From, A.M.4    Torner, J.C.5
  • 13
    • 46049116454 scopus 로고    scopus 로고
    • Optimizing glenosphere position and fixation in reverse shoulder arthroplasty, Part Two: the three-column concept
    • Humphrey C.S., Kelly J.D., and Norris T.R. Optimizing glenosphere position and fixation in reverse shoulder arthroplasty, Part Two: the three-column concept. J Shoulder Elbow Surg 17 (2008) 595-601
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 595-601
    • Humphrey, C.S.1    Kelly, J.D.2    Norris, T.R.3
  • 14
    • 46049086371 scopus 로고    scopus 로고
    • Optimizing glenosphere position and fixation in reverse shoulder arthroplasty, Part One: the twelve-mm rule
    • Kelly J.D., Humphrey C.S., and Norris T.R. Optimizing glenosphere position and fixation in reverse shoulder arthroplasty, Part One: the twelve-mm rule. J Shoulder Elbow Surg 17 (2008) 589-594
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 589-594
    • Kelly, J.D.1    Humphrey, C.S.2    Norris, T.R.3
  • 15
    • 13844270863 scopus 로고    scopus 로고
    • Use of three-dimensional computed tomography for the analysis of the glenoid anatomy
    • Kwon Y.W., Powell K.A., Yum J.K., Brems J.J., and Iannotti J.P. Use of three-dimensional computed tomography for the analysis of the glenoid anatomy. J Shoulder Elbow Surg 14 (2005) 85-90
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 85-90
    • Kwon, Y.W.1    Powell, K.A.2    Yum, J.K.3    Brems, J.J.4    Iannotti, J.P.5
  • 16
    • 33947250333 scopus 로고    scopus 로고
    • Use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty in patients with glenohumeral arthritis and rotator cuff deficiency
    • Levy J.C., Virani N., Pupello D., and Frankle M. Use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty in patients with glenohumeral arthritis and rotator cuff deficiency. J Bone Joint Surg Br 89 (2007) 189-195
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 189-195
    • Levy, J.C.1    Virani, N.2    Pupello, D.3    Frankle, M.4
  • 17
    • 25444490893 scopus 로고    scopus 로고
    • Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis
    • Nyffeler R.W., Werner C.M., and Gerber C. Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elbow Surg 14 (2005) 524-528
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 524-528
    • Nyffeler, R.W.1    Werner, C.M.2    Gerber, C.3
  • 19
    • 34447296220 scopus 로고    scopus 로고
    • Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies
    • Seller K., Wahl D., Wild A., Krauspe R., Schneider E., and Linke B. Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies. Eur Spine J 16 (2007) 1047-1054
    • (2007) Eur Spine J , vol.16 , pp. 1047-1054
    • Seller, K.1    Wahl, D.2    Wild, A.3    Krauspe, R.4    Schneider, E.5    Linke, B.6
  • 20
    • 33847633584 scopus 로고    scopus 로고
    • Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement
    • Simovitch R.W., Zumstein M.A., Lohri E., Helmy N., and Gerber C. Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement. J Bone Joint Surg Am 89 (2007) 588-600
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 588-600
    • Simovitch, R.W.1    Zumstein, M.A.2    Lohri, E.3    Helmy, N.4    Gerber, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.