메뉴 건너뛰기




Volumn 48, Issue 3, 2009, Pages 295-310

Electron paramagnetic resonance in irradiated fingernails: Variability of dose dependence and possibilities of initial dose assessment

Author keywords

[No Author keywords available]

Indexed keywords

COLLECTION TIME; CONTROL OF SIZE; DOSE ASSESSMENTS; DOSE DEPENDENCES; DOSE MEASUREMENT; DOSE RANGE; DOSE RESPONSE; DRYING TIME; ELECTRON PARAMAGNETIC RESONANCE; EXPONENTIAL GROWTH; KEY FACTORS; MEAN DOSE; MECHANICAL STRESS; NUMBER AND SIZE; PER UNIT; RADIATION SENSITIVITY; ROOM TEMPERATURE; SPECIAL TREATMENTS; WATER SOAKING;

EID: 70349782642     PISSN: 0301634X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00411-009-0232-1     Document Type: Article
Times cited : (30)

References (10)
  • 2
    • 0023258124 scopus 로고
    • Sulphur radicals formed by cutting α-keratin
    • DOI 10.1038/328833a0
    • H Chandra MC Symons 1987 Sulphur radicals formed by cutting alpha-keratin Nature 328 833 834 10.1038/328833a0 1987Natur.328..833C (Pubitemid 17125964)
    • (1987) Nature , vol.328 , Issue.6133 , pp. 833-834
    • Chandra, H.1    Symons, M.C.R.2
  • 3
    • 0024804554 scopus 로고
    • Evaluation of ESR as a radiation accident dosimetry technique
    • DOI 10.1016/0883-2889(89)90034-8
    • BG Dalgarno JD McClymont 1989 Evaluation of ESR as a radiation accident dosimetry technique Appl Radiat Isot 40 1013 1020 10.1016/0883-2889(89)90034-8 (Pubitemid 20071812)
    • (1989) Applied Radiation and Isotopes , vol.40 , Issue.10-12 , pp. 1013-1020
    • Dalgarno, B.G.1    McClymont, J.D.2
  • 4
    • 33645571737 scopus 로고    scopus 로고
    • In vivo measurement of water content of the fingernail and its seasonal change
    • 10.1111/j.0909-752X.2006.00141.x
    • M Egawa Y Ozaki M Takahashi 2006 In vivo measurement of water content of the fingernail and its seasonal change Skin Res Technol 12 126 132 10.1111/j.0909-752X.2006.00141.x
    • (2006) Skin Res Technol , vol.12 , pp. 126-132
    • Egawa, M.1    Ozaki, Y.2    Takahashi, M.3
  • 5
    • 0030110227 scopus 로고    scopus 로고
    • Errors in dose assessment introduced by the use of the "linear part" of a saturating dose response curve
    • DOI 10.1016/1350-4487(95)00311-8
    • R Grun 1996 Errors in dose assessment introduced by the use of the linear part of a saturating dose response curve Radiat Meas 26 297 302 10.1016/1350-4487(95)00311-8 (Pubitemid 126401804)
    • (1996) Radiation Measurements , vol.26 , Issue.2 , pp. 297-302
    • Grun, R.1
  • 9
    • 0028860310 scopus 로고
    • Electron paramagnetic resonance spectra of irradiated finger-nails: A possible measure of accidental exposure
    • MC Symons H Chandra JL Wyatt 1995 Electron paramagnetic resonance spectra of irradiated finger-nails: a possible measure of accidental exposure Radiat Prot Dosimetry 58 11 15
    • (1995) Radiat Prot Dosimetry , vol.58 , pp. 11-15
    • Symons, M.C.1    Chandra, H.2    Wyatt, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.