COLLECTION TIME;
CONTROL OF SIZE;
DOSE ASSESSMENTS;
DOSE DEPENDENCES;
DOSE MEASUREMENT;
DOSE RANGE;
DOSE RESPONSE;
DRYING TIME;
ELECTRON PARAMAGNETIC RESONANCE;
EXPONENTIAL GROWTH;
KEY FACTORS;
MEAN DOSE;
MECHANICAL STRESS;
NUMBER AND SIZE;
PER UNIT;
RADIATION SENSITIVITY;
ROOM TEMPERATURE;
SPECIAL TREATMENTS;
WATER SOAKING;
ELECTRON RESONANCE;
ELECTRON SPIN RESONANCE SPECTROSCOPY;
FLUORINE CONTAINING POLYMERS;
PARAMAGNETIC MATERIALS;
PARAMAGNETIC RESONANCE;
PARAMAGNETISM;
QUANTUM THEORY;
WATER CONTENT;
BiodosEPR-2006 Meeting: Acute dosimetry consensus committee recommendations on biodosimetry applications in events involving uses of radiation by terrorists and radiation accidents
DOI 10.1016/j.radmeas.2007.05.035, PII S1350448707002533
GA Alexander HM Swartz SA Amundson WF Blakely B Buddemeier B Gallez N Dainiak RE Goans RB Hayes PC Lowry MA Noska P Okunieff AL Salner DA Schauer F Trompier KW Turteltaub P Voisin AL Wiley Jr R Wilkins 2007 Acute dosimetry consensus committee recommendations on biodosimetry applications in events involving uses of radiation by terrorists and radiation accidents Radiat Meas 42 972 996 10.1016/j.radmeas.2007.05.035 (Pubitemid 47449638)
In vivo measurement of water content of the fingernail and its seasonal change
10.1111/j.0909-752X.2006.00141.x
M Egawa Y Ozaki M Takahashi 2006 In vivo measurement of water content of the fingernail and its seasonal change Skin Res Technol 12 126 132 10.1111/j.0909-752X.2006.00141.x
Errors in dose assessment introduced by the use of the "linear part" of a saturating dose response curve
DOI 10.1016/1350-4487(95)00311-8
R Grun 1996 Errors in dose assessment introduced by the use of the linear part of a saturating dose response curve Radiat Meas 26 297 302 10.1016/1350-4487(95)00311-8 (Pubitemid 126401804)
Electron paramagnetic resonance in human fingernails: The sponge model implication
10.1007/s00411-008-0178-8
RA Reyes A Romanyukha F Trompier CA Mitchell I Clairand T De LA Benevides HM Swartz 2008 Electron paramagnetic resonance in human fingernails: the sponge model implication Radiat Environ Biophys 47 515 526 10.1007/s00411-008-0178-8
DOI 10.1016/j.radmeas.2007.05.026, PII S1350448707002417
A Romanyukha F Trompier B LeBlanc C Calas I Clairand C Mitchell JG Smirniotopoulos HM Swartz 2007 EPR dosimetry in chemically treated fingernails Radiat Meas 42 1110 1113 10.1016/j.radmeas.2007.05.026 (Pubitemid 47430034)
Electron paramagnetic resonance spectra of irradiated finger-nails: A possible measure of accidental exposure
MC Symons H Chandra JL Wyatt 1995 Electron paramagnetic resonance spectra of irradiated finger-nails: a possible measure of accidental exposure Radiat Prot Dosimetry 58 11 15
Protocol for emergency EPR dosimetry in fingernails
DOI 10.1016/j.radmeas.2007.05.024, PII S1350448707002375
F Trompier L Kornak C Calas A Romanyukha B LeBlanc I Clairand C Mitchell HM Swartz 2007 Protocol for emergency EPR dosimetry in fingernails Radiat Meas 42 1085 1088 10.1016/j.radmeas.2007.05.024 (Pubitemid 47430030)