메뉴 건너뛰기




Volumn 28, Issue 9, 2009, Pages 1019-1022

Stability of the posterior corneal surface after laser surface ablation for myopia

Author keywords

LASEK; Laser surface ablation; Posterior corneal surface; PRK

Indexed keywords

ADULT; ANTERIOR EYE CHAMBER DEPTH; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED STUDY; CORNEA CURVATURE; FEMALE; HUMAN; LASER EPITHELIAL KERATOMILEUSIS; MALE; MYOPIA; PHOTOREFRACTIVE KERATECTOMY; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; TREATMENT OUTCOME;

EID: 70349730263     PISSN: 02773740     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICO.0b013e3181a06f1e     Document Type: Article
Times cited : (39)

References (23)
  • 1
    • 0030732384 scopus 로고    scopus 로고
    • Posterior corneal protrusion after PRK
    • Shimmura S, Yang HY, Bissen-Miyajima H, et al. Posterior corneal protrusion after PRK. Cornea. 1997;16:686-688.
    • (1997) Cornea , vol.16 , pp. 686-688
    • Shimmura, S.1    Yang, H.Y.2    Bissen-Miyajima, H.3
  • 2
    • 0031779852 scopus 로고    scopus 로고
    • Iatrogenic keratectasia after laser in situ keratomileusis
    • Seiler T, Koufala K, Richter G. Iatrogenic keratectasia after laser in situ keratomileusis. J Refract Surg. 1998;14:312-317. (Pubitemid 28265754)
    • (1998) Journal of Refractive Surgery , vol.14 , Issue.3 , pp. 312-317
    • Seiler, T.1    Koufala, K.2    Richter, G.3
  • 3
    • 0031813262 scopus 로고    scopus 로고
    • Iatrogenic keratectasia after LASIK in a case of forme fruste keratoconus
    • Seiler T, Quurke AW. Iatrogenic keratectasia after LASIK in a case of forme fruste keratoconus. J Cataract Refract Surg. 1998;24:1007-1009. (Pubitemid 28335260)
    • (1998) Journal of Cataract and Refractive Surgery , vol.24 , Issue.7 , pp. 1007-1009
    • Seiler, T.1    Quurke, A.W.2
  • 4
    • 0033960587 scopus 로고    scopus 로고
    • Corneal ectasia detected after laser in situ keratomileusis for correction of less than -12 diopters of myopia
    • DOI 10.1016/S0886-3350(99)00340-5, PII S0886335099003405
    • Joo CK, Kim TG. Corneal ectasia detected after laser in situ keratomileusis for correction of less than -12 diopters of myopia. J Cataract Refract Surg. 2000;26:292-295. (Pubitemid 30094313)
    • (2000) Journal of Cataract and Refractive Surgery , vol.26 , Issue.2 , pp. 292-295
    • Joo, C.-K.1    Kim, T.-G.2
  • 6
    • 0033927056 scopus 로고    scopus 로고
    • Changes in posterior corneal curvature after photorefractive keratectomy
    • DOI 10.1016/S0886-3350(00)00413-2, PII S0886335000004132
    • Naroo SA, Charman WN. Changes in posterior corneal curvature after photorefractive keratectomy. J Cataract Refract Surg. 2000;26:872-878. (Pubitemid 30482628)
    • (2000) Journal of Cataract and Refractive Surgery , vol.26 , Issue.6 , pp. 872-878
    • Naroo, S.A.1    Charman, W.N.2
  • 8
    • 0035086297 scopus 로고    scopus 로고
    • Posterior corneal curvature changes after myopic laser in situ keratomileusis
    • DOI 10.1016/S0161-6420(00)00581-9
    • Seitz B, Torres F, Langenbucher A, et al. Posterior corneal curvature changes after myopic laser in situ keratomileusis. Ophthalmology. 2001; 108:666-673. (Pubitemid 32238459)
    • (2001) Ophthalmology , vol.108 , Issue.4 , pp. 666-672
    • Seitz, B.1    Torres, F.2    Langenbucher, A.3    Behrens, A.4    Suarez, E.5
  • 9
    • 29244433022 scopus 로고    scopus 로고
    • Comparison of forward shift of posterior corneal surface after operation between LASIK and LASEK
    • DOI 10.1159/000089273
    • Kim H, Kim HJ, Joo CK. Comparison of forward shift of posterior corneal surface after operation between LASIK and LASEK. Ophthalmologica. 2006;220:37-42. (Pubitemid 41832693)
    • (2006) Ophthalmologica , vol.220 , Issue.1 , pp. 37-42
    • Kim, H.1    Hyun, J.K.2    Joo, C.-K.3
  • 10
    • 0035000858 scopus 로고    scopus 로고
    • Orbscan pachymetry after LASIK is not reliable [2]
    • Giessler S, Duncker GI. Orbscan pachymetry after LASIK is not reliable. J Refract Surg. 2001;17:385-387. (Pubitemid 32487876)
    • (2001) Journal of Refractive Surgery , vol.17 , Issue.3 , pp. 385-387
    • Giessler, S.1    Duncker, G.I.W.2
  • 11
    • 0037373268 scopus 로고    scopus 로고
    • Reliability of pachymetric measurements using Orbscan after excimer refractive surgery
    • DOI 10.1016/S0161-6420(02)01298-8, PII S0161642002012988
    • Prisant O, Calderon N, Chastang P, et al. Reliability of pachymetric measurements using Orbscan after excimer refractive surgery. Ophthalmology. 2003;110:511-515. (Pubitemid 36262733)
    • (2003) Ophthalmology , vol.110 , Issue.3 , pp. 511-515
    • Prisant, O.1    Calderon, N.2    Chastang, P.3    Gatinel, D.4    Hoang-Xuan, T.5
  • 12
    • 0037591142 scopus 로고    scopus 로고
    • Corneal forward shift after excimer laser keratorefractive surgery
    • DOI 10.1076/soph.18.1.17.14070
    • Kamiya K, Oshika T. Corneal forward shift after excimer laser keratorefractive surgery. Semin Ophthalmol. 2003;18:17-22. (Pubitemid 36993549)
    • (2003) Seminars in Ophthalmology , vol.18 , Issue.1 , pp. 17-22
    • Kamiya, K.1    Oshika, T.2
  • 14
    • 0035150749 scopus 로고    scopus 로고
    • Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis
    • DOI 10.1016/S0161-6420(00)00502-9, PII S0161642000005029
    • Baek T, Lee K, Kagaya F, et al. Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis. Ophthalmology. 2001;108:317-320. (Pubitemid 32115962)
    • (2001) Ophthalmology , vol.108 , Issue.2 , pp. 317-320
    • Baek, T.M.1    Lee, K.H.2    Kagaya, F.3    Tomidokoro, A.4    Amano, S.5    Oshika, T.6
  • 15
    • 33747364036 scopus 로고    scopus 로고
    • Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy
    • DOI 10.1016/j.jcrs.2006.03.037, PII S0886335006006626
    • Ciolino JB, Belin MW. Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy. J Cataract Refract Surg. 2006;32:1426-1431. (Pubitemid 44247476)
    • (2006) Journal of Cataract and Refractive Surgery , vol.32 , Issue.9 , pp. 1426-1431
    • Ciolino, J.B.1    Belin, M.W.2
  • 16
    • 34249735491 scopus 로고    scopus 로고
    • No Forward Shifting of Posterior Corneal Surface in Eyes Undergoing LASIK
    • DOI 10.1016/j.ophtha.2006.09.014, PII S0161642006013121
    • Nishimura R, Negishi K, Saiki M, et al. No forward shifting of posterior corneal surface in eyes undergoing LASIK. Ophthalmology. 2007;114: 1104-1110. (Pubitemid 46829365)
    • (2007) Ophthalmology , vol.114 , Issue.6 , pp. 1104-1110
    • Nishimura, R.1    Negishi, K.2    Saiki, M.3    Arai, H.4    Shimizu, S.5    Toda, I.6    Tsubota, K.7
  • 17
  • 18
    • 0035161383 scopus 로고    scopus 로고
    • Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes
    • DOI 10.1016/S0886-3350(01)01089-6, PII S0886335001010896
    • Chakrabarti HS, Craig JP, Brahma A, et al. Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes. J Cataract Refract Surg. 2001;27:1823-1828. (Pubitemid 33055554)
    • (2001) Journal of Cataract and Refractive Surgery , vol.27 , Issue.11 , pp. 1823-1828
    • Chakrabarti, H.S.1    Craig, J.P.2    Brahma, A.3    Malik, T.Y.4    McGhee, C.N.J.5
  • 19
    • 0035737828 scopus 로고    scopus 로고
    • Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness
    • DOI 10.1097/00003226-200110000-00008
    • Módis L Jr, Langenbucher A, Seitz B. Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness. Cornea. 2001;20:711-714. (Pubitemid 34506468)
    • (2001) Cornea , vol.20 , Issue.7 , pp. 711-714
    • Modis Jr., L.1    Langenbucher, A.2    Seitz, B.3
  • 21
    • 36448970833 scopus 로고    scopus 로고
    • Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry
    • Kim SW, Byun YJ, Kim EK, et al. Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry. J Refract Surg. 2007;23:888-894. (Pubitemid 350175113)
    • (2007) Journal of Refractive Surgery , vol.23 , Issue.9 , pp. 888-894
    • Sun, W.K.1    Yeo, J.B.2    Eung, K.K.3    Kim, T.-I.4
  • 22
    • 18644386012 scopus 로고    scopus 로고
    • Assessing the accuracy of Orbscan II post-LASIK: Apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures
    • DOI 10.1111/j.1442-9071.2005.00975.x
    • Cairns G, Ormonde SE, Gray T, et al. Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures. Clin Exp Ophthalmol. 2005;33:147-152. (Pubitemid 40662778)
    • (2005) Clinical and Experimental Ophthalmology , vol.33 , Issue.2 , pp. 147-152
    • Cairns, G.1    Ormonde, S.E.2    Gray, T.3    Hadden, O.B.4    Morris, T.5    Ring, P.6    McGhee, C.N.J.7
  • 23
    • 39749086945 scopus 로고    scopus 로고
    • Corneal magnification
    • Nawa Y. Corneal magnification. Ophthalmology. 2008;115:588.
    • (2008) Ophthalmology , vol.115 , pp. 588
    • Nawa, Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.