메뉴 건너뛰기




Volumn 36, Issue 10, 2009, Pages 4511-4518

A more accurate reconstruction system matrix for quantitative proton computed tomography

Author keywords

Chord length; Iterative projection methods; Proton computed tomography; System matrix

Indexed keywords

COMPUTATIONAL EFFICIENCY; COMPUTERIZED TOMOGRAPHY; ITERATIVE METHODS; MATRIX ALGEBRA; PHANTOMS; SYSTEMATIC ERRORS;

EID: 70349705642     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3218759     Document Type: Article
Times cited : (55)

References (21)
  • 1
    • 0026515872 scopus 로고
    • Differential-pencil-beam dose calculations for charged particles
    • 0094-2405,. 10.1118/1.596887
    • P. L. Petti, " Differential-pencil-beam dose calculations for charged particles.," Med. Phys. 0094-2405 19, 137-149 (1992). 10.1118/1.596887
    • (1992) Med. Phys. , vol.19 , pp. 137-149
    • Petti, P.L.1
  • 4
    • 0020681789 scopus 로고
    • The relation between x-ray CT numbers and charged particle stopping powers and its significance for radiotherapy treatment planning
    • 0031-9155,. 10.1088/0031-9155/28/2/006
    • A. A. Mustafa and D. F. Jackson, " The relation between x-ray CT numbers and charged particle stopping powers and its significance for radiotherapy treatment planning.," Phys. Med. Biol. 0031-9155 28, 169-176 (1983). 10.1088/0031-9155/28/2/006
    • (1983) Phys. Med. Biol. , vol.28 , pp. 169-176
    • Mustafa, A.A.1    Jackson, D.F.2
  • 5
    • 0030065290 scopus 로고    scopus 로고
    • The calibration of CT Hounsfield units for radiotherapy treatment planning
    • DOI 10.1088/0031-9155/41/1/009
    • U. Schneider, E. Pedroni, and A. Lomax, " The calibration of CT Hounsfield units for radiotherapy treatment planning.," Phys. Med. Biol. 0031-9155 41, 111-124 (1996). 10.1088/0031-9155/41/1/009 (Pubitemid 26034228)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.1 , pp. 111-124
    • Schneider, U.1    Pedroni, E.2    Lomax, A.3
  • 6
    • 0031807135 scopus 로고    scopus 로고
    • The precision of proton range calculations in proton radiotherapy treatment planning: Experimental verification of the relation between CT-HU and proton stopping power
    • DOI 10.1088/0031-9155/43/6/016, PII S0031915598876744
    • B. Schaffner and E. Pedroni, " The precision of proton range calculations in proton radiotherapy treatment planning: Experimental verification of the relation between CT-HU and proton stopping power.," Phys. Med. Biol. 0031-9155 43, 1579-1592 (1998). 10.1088/0031-9155/43/6/016 (Pubitemid 28277296)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.6 , pp. 1579-1592
    • Schaffner, B.1    Pedroni, E.2
  • 8
    • 54949089317 scopus 로고    scopus 로고
    • A maximum likelihood proton path formalism for application in proton computed tomography
    • 0094-2405,. 10.1118/1.2986139
    • R. W. Schulte, S. N. Penfold, J. T. Tafas, and K. E. Schubert, " A maximum likelihood proton path formalism for application in proton computed tomography.," Med. Phys. 0094-2405 35, 4849-4856 (2008). 10.1118/1.2986139
    • (2008) Med. Phys. , vol.35 , pp. 4849-4856
    • Schulte, R.W.1    Penfold, S.N.2    Tafas, J.T.3    Schubert, K.E.4
  • 9
    • 33644635909 scopus 로고    scopus 로고
    • Reconstruction for proton computed tomography by tracing proton trajectories: A Monte Carlo study
    • DOI 10.1118/1.2171507
    • T. Li, Z. Liang, J. V. Singanallur, T. J. Satogata, D. C. Williams, and R. W. Schulte, " Reconstruction for proton computed tomography by tracing proton trajectories: A Monte Carlo study.," Med. Phys. 0094-2405 33, 699-706 (2006). 10.1118/1.2171507 (Pubitemid 43320173)
    • (2006) Medical Physics , vol.33 , Issue.3 , pp. 699-706
    • Li, T.1    Liang, Z.2    Singanallur, J.V.3    Satogata, T.J.4    Williams, D.C.5    Schulte, R.W.6
  • 10
    • 84976870425 scopus 로고
    • Zur theorie des durchgangs schneller korpuskularstrahlen durch materie
    • 0003-3804,. 10.1002/and19303970303
    • H. Bethe, " Zur theorie des durchgangs schneller korpuskularstrahlen durch materie.," Ann. Phys. 0003-3804 397, 325-400 (1930). 10.1002/andp.19303970303
    • (1930) Ann. Phys. , vol.397 , pp. 325-400
    • Bethe, H.1
  • 11
    • 0014905513 scopus 로고
    • Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography
    • 0022-5193,. 10.1016/0022-5193(70)90109-8
    • R. Gordon, R. Bender, and G. T. Herman, " Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography.," J. Theor. Biol. 0022-5193 29, 471-481 (1970). 10.1016/0022-5193(70)90109-8
    • (1970) J. Theor. Biol. , vol.29 , pp. 471-481
    • Gordon, R.1    Bender, R.2    Herman, G.T.3
  • 12
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • DOI 10.1118/1.595715
    • R. L. Siddon, " Fast calculation of the exact radiological path for a three-dimensional CT array.," Med. Phys. 0094-2405 12, 252-255 (1985). 10.1118/1.595715 (Pubitemid 15089015)
    • (1985) Medical Physics , vol.12 , Issue.2 , pp. 252-255
    • Siddon, R.L.1
  • 13
    • 0011082596 scopus 로고
    • Thomas Bayes' Bayesian inference
    • 10.2307/2981538 0035-9238
    • S. M. Stigler, " Thomas Bayes' Bayesian inference.," J. R. Stat. Soc. Ser A (Gen.) 145, 250-258 (1982). 10.2307/2981538 0035-9238
    • (1982) J. R. Stat. Soc. ser A (Gen.) , vol.145 , pp. 250-258
    • Stigler, S.M.1
  • 14
    • 36149020805 scopus 로고
    • Multiple scattering with energy loss
    • 0096-8250,. 10.1103/PhysRev.74.1534
    • L. Eyges, " Multiple scattering with energy loss.," Phys. Rev. 0096-8250 74, 1534-1535 (1948). 10.1103/PhysRev.74.1534
    • (1948) Phys. Rev. , vol.74 , pp. 1534-1535
    • Eyges, L.1
  • 15
    • 0038377458 scopus 로고    scopus 로고
    • GEANT4-A simulation toolkit
    • 0168-9002,. 10.1016/S0168-9002(03)01368-8
    • S. Agostinelli, " GEANT4-A simulation toolkit.," Nucl. Instrum. Methods Phys. Res. A 0168-9002 506, 250-303 (2003). 10.1016/S0168-9002(03) 01368-8
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 17
    • 85027233994 scopus 로고
    • International Commission on Radiological Protection, "Report of the Task Grouon Reference Man," ICRP Publication 23 (Elsevier, Philadelphia).
    • International Commission on Radiological Protection, "Report of the Task Group on Reference Man," ICRP Publication 23 (Elsevier, Philadelphia, 1975).
    • (1975)
  • 18
    • 11944250714 scopus 로고    scopus 로고
    • The requirements and limitations of computer simulations applied to proton computed tomography
    • J. Heimann, L. Johnson, T. Satogata, and D. C. Williams, " The requirements and limitations of computer simulations applied to proton computed tomography.," IEEE NSS-MIC Conference Proceedings (2004), pp. 3663-3666.
    • (2004) IEEE NSS-MIC Conference Proceedings , pp. 3663-3666
    • Heimann, J.1    Johnson, L.2    Satogata, T.3    Williams, D.C.4
  • 19
    • 0001824725 scopus 로고
    • Three methods for reconstructing objects from x-rays: A comparative study
    • 0146-664X,. 10.1016/0146-664X(73)90025-7
    • G. T. Herman and S. W. Rowland, " Three methods for reconstructing objects from x-rays: A comparative study.," Comput. Graph. Image Process. 0146-664X 2, 151-178 (1973). 10.1016/0146-664X(73)90025-7
    • (1973) Comput. Graph. Image Process. , vol.2 , pp. 151-178
    • Herman, G.T.1    Rowland, S.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.