메뉴 건너뛰기




Volumn 20, Issue 5, 2009, Pages 1533-1537

An enhanced strength retention poly(glycolic acid)-poly(L-lactic acid) copolymer for internal fixation: In vitro characterization of hydrolysis

Author keywords

Bioabsorbable; Copolymer; Internal fixation; LactoSorb; PGA; PLLA

Indexed keywords

POLYGLACTIN;

EID: 70349694727     PISSN: 10492275     EISSN: None     Source Type: Journal    
DOI: 10.1097/SCS.0b013e3181b09bd8     Document Type: Article
Times cited : (17)

References (35)
  • 1
    • 0031708568 scopus 로고    scopus 로고
    • Background of the early development of absorbable fixation devices
    • Viljanen VV, Lindholm TS. Background of the early development of absorbable fixation devices. Tech Orthop 1998;13:117-122
    • (1998) Tech Orthop , vol.13 , pp. 117-122
    • Viljanen, V.V.1    Lindholm, T.S.2
  • 2
    • 0030965117 scopus 로고    scopus 로고
    • Bioabsorbable fixation devices: Status for the craniomaxillofacial surgeon
    • Pietrzak WS, Verstynen ML, Sarver DR. Bioabsorbable fixation devices: status for the craniomaxillofacial surgeon. J Craniofac Surg 1997;8:92-96
    • (1997) J Craniofac Surg , vol.8 , pp. 92-96
    • Pietrzak, W.S.1    Verstynen, M.L.2    Sarver, D.R.3
  • 4
    • 0033843338 scopus 로고    scopus 로고
    • Principles of development and use of absorbable internal fixation
    • DOI 10.1089/107632700418128
    • Pietrzak WS. Principles of development and use of absorbable internal fixation. Tissue Eng 2000;6:425-433 (Pubitemid 30655950)
    • (2000) Tissue Engineering , vol.6 , Issue.4 , pp. 425-433
    • Pietrzak, W.S.1
  • 5
    • 70349724139 scopus 로고    scopus 로고
    • Bioabsorbable polymer applications in musculoskeletal fixation and healing
    • Pietrzak WS, ed. Totowa, NJ: Humana Press
    • Pietrzak WS. Bioabsorbable polymer applications in musculoskeletal fixation and healing. In: Pietrzak WS, ed. Musculoskeletal Tissue Regeneration: Biological Materials and Methods. Totowa, NJ: Humana Press, 2008:509-529
    • (2008) Musculoskeletal Tissue Regeneration: Biological Materials and Methods , pp. 509-529
    • Pietrzak, W.S.1
  • 6
    • 5144230315 scopus 로고    scopus 로고
    • Successful use of biosorb osteofixation devices in 165 cranial and maxillofacial cases: A multicenter report
    • Ashammakhi N, Renier D, Arnaud E, et al. Successful use of biosorb osteofixation devices in 165 cranial and maxillofacial cases: a multicenter report. J Craniofac Surg 2004;15:692-701
    • (2004) J Craniofac Surg , vol.15 , pp. 692-701
    • Ashammakhi, N.1    Renier, D.2    Arnaud, E.3
  • 8
    • 33645830518 scopus 로고    scopus 로고
    • Clinical experience with a new fast-resorbing polymer for bone stabilization in craniofacial surgery
    • Cohen SR, Mittermiller PA, Holmes RE, et al. Clinical experience with a new fast-resorbing polymer for bone stabilization in craniofacial surgery. J Craniofac Surg 2006;17:40-43
    • (2006) J Craniofac Surg , vol.17 , pp. 40-43
    • Cohen, S.R.1    Mittermiller, P.A.2    Holmes, R.E.3
  • 9
    • 33645824340 scopus 로고    scopus 로고
    • A resorbable rivet system for pediatric craniofacial surgery: Biomechanical testing and clinical experience
    • Eppley BL, Pietrzak WS. A resorbable rivet system for pediatric craniofacial surgery: biomechanical testing and clinical experience. J Craniofac Surg 2006;17:11-14
    • (2006) J Craniofac Surg , vol.17 , pp. 11-14
    • Eppley, B.L.1    Pietrzak, W.S.2
  • 10
    • 44649102808 scopus 로고    scopus 로고
    • Outcomes and complications based on experience with resorbable plates in pediatric craniosynostosis patients
    • DOI 10.1097/SCS.0b013e31816ae358, PII 0000166520080500000060
    • Ahmad N, Lyles J, Panchal J. Outcomes and complications based on experience with resorbable plates in pediatric craniosynostosis patients. J Craniofac Surg 2008;19:855-860 (Pubitemid 351786526)
    • (2008) Journal of Craniofacial Surgery , vol.19 , Issue.3 , pp. 855-860
    • Ahmad, N.1    Lyles, J.2    Panchal, J.3
  • 11
    • 33748587280 scopus 로고    scopus 로고
    • One-year postoperative stability of LeFort I osteotomies with biodegradable fixation: A retrospective analysis of skeletal relapse
    • Kiely KD, Wendfeldt KS, Johnson BE, et al. One-year postoperative stability of LeFort I osteotomies with biodegradable fixation: a retrospective analysis of skeletal relapse. Am J Orthod Dentofacial Orthop 2006;130:310-316
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 310-316
    • Kiely, K.D.1    Wendfeldt, K.S.2    Johnson, B.E.3
  • 13
    • 40249100266 scopus 로고    scopus 로고
    • A prospective trial of poly-L-lactic/polyglycolic acid co-polymer plates and screws for internal fixation of mandibular fractures
    • DOI 10.1016/j.ijom.2007.11.015, PII S0901502707010600
    • Ferretti C. A prospective trial of poly-L-lactic/polyglycolic acid co-polymer plates and screws for internal fixation of mandibular fractures. Int J Oral Maxillofac Surg 2008;37:242-248 (Pubitemid 351335246)
    • (2008) International Journal of Oral and Maxillofacial Surgery , vol.37 , Issue.3 , pp. 242-248
    • Ferretti, C.1
  • 15
    • 20444431570 scopus 로고    scopus 로고
    • Fixation of the chevron osteotomy with an absorbable copolymer pin for the treatment of hallux valgus deformity
    • Caminear DS, Pavlovich R Jr, Pietrzak WS. Fixation of the chevron osteotomy with an absorbable copolymer pin for the treatment of hallux valgus deformity. J Foot Ankle Surg 2005;44:203-210
    • (2005) J Foot Ankle Surg , vol.44 , pp. 203-210
    • Caminear, D.S.1    Pavlovich Jr., R.2    Pietrzak, W.S.3
  • 16
    • 0141576610 scopus 로고    scopus 로고
    • The bioresorbable syndesmotic screw: Application of polymer technology in ankle fractures
    • Miller SD, Carls RJ. The bioresorbable syndesmotic screw: application of polymer technology in ankle fractures. Am J Orthop 2002;31(1 suppl):18-21
    • (2002) Am J Orthop , vol.31 , Issue.1 SUPPL. , pp. 18-21
    • Miller, S.D.1    Carls, R.J.2
  • 17
    • 11144272811 scopus 로고    scopus 로고
    • Fixation of osteochondritis dissecans lesions using poly(L-lactic acid)/poly(glycolic acid) copolymer bioabsorbable screws
    • Larsen MW, Pietrzak WS, DeLee JC. Fixation of osteochondritis dissecans lesions using poly(L-lactic acid)/poly(glycolic acid) copolymer bioabsorbable screws. Am J Sports Med 2005;33:68-76
    • (2005) Am J Sports Med , vol.33 , pp. 68-76
    • Larsen, M.W.1    Pietrzak, W.S.2    DeLee, J.C.3
  • 18
    • 30544446942 scopus 로고    scopus 로고
    • Dorsal plating of unstable distal radius fractures using a bio-absorbable plating system and bone substitute
    • DOI 10.1016/j.jhsb.2005.09.015, PII S0266768105003074
    • Gangopadhyay S, Ravi K, Packer G. Dorsal plating of unstable distal radius fractures using a bio-absorbable plating system and bone substitute. J Hand Surg [Br] 2005;31:93-100 (Pubitemid 43079104)
    • (2006) Journal of Hand Surgery , vol.31 , Issue.1 , pp. 93-100
    • Gangopadhyay, S.1    Ravi, K.2    Packer, G.3
  • 19
    • 0036524504 scopus 로고    scopus 로고
    • LactoSorb plates for rotator cuff repair
    • DOI 10.1053/jars.2002.30484
    • Kessler KJ, Bullens-Borrow AE, Zisholtz J. LactoSorb plates for rotator cuff repair. Arthroscopy 2002;18:279-283 (Pubitemid 36114583)
    • (2002) Arthroscopy , vol.18 , Issue.3 , pp. 279-283
    • Kessler, K.J.1    Bullens-Borrow, A.E.2    Zisholtz, J.3
  • 20
    • 0035165602 scopus 로고    scopus 로고
    • The fate of resorbable poly-L-lactic/polyglycolic acid (LactoSorb) bone fixation devices in orthognathic surgery
    • DOI 10.1053/joms.2001.19267
    • Edwards RC, Kiely KD, Eppley BL. The fate of resorbable poly-L-lactic/ polyglycolic acid (LactoSorb) bone fixation devices in orthognathic surgery. J Oral Maxillofac Surg 2001;59:19-25 (Pubitemid 32051776)
    • (2001) Journal of Oral and Maxillofacial Surgery , vol.59 , Issue.1 , pp. 19-25
    • Edwards, R.C.1    Kiely, K.D.2    Eppley, B.L.3
  • 21
    • 0030940782 scopus 로고    scopus 로고
    • Nonmetallic fixation in traumatic midfacial fractures
    • Eppley BL, Prevel CD. Nonmetallic fixation in traumatic midfacial fractures. J Craniofac Surg 1997;8:103-109
    • (1997) J Craniofac Surg , vol.8 , pp. 103-109
    • Eppley, B.L.1    Prevel, C.D.2
  • 22
    • 0030908235 scopus 로고    scopus 로고
    • Degradation characteristics of PLLA-PGA bone fixation devices
    • Eppley BL, Reilly M. Degradation characteristics of PLLA-PGA bone fixation devices. J Craniofac Surg 1997;8:116-120 (Pubitemid 27220083)
    • (1997) Journal of Craniofacial Surgery , vol.8 , Issue.2 , pp. 116-120
    • Eppley, B.L.1    Reilly, M.2
  • 23
    • 0031763372 scopus 로고    scopus 로고
    • Fixation of osteotomies using bioabsorbable screws in the canine femur
    • An YH, Friedman RJ, Powers DL, et al. Fixation of osteotomies using bioabsorbable screws in the canine femur. Clin Orthop Rel Res 1997;355:300-311
    • (1997) Clin Orthop Rel Res , vol.355 , pp. 300-311
    • An, Y.H.1    Friedman, R.J.2    Powers, D.L.3
  • 24
    • 0031105456 scopus 로고    scopus 로고
    • Effect of simulated intraoperative heating and shaping on mechanical properties of a bioabsorbable fracture plate material
    • Pietrzak WS, Sarver DR, Bianchini SD, et al. Effect of simulated intraoperative heating and shaping on mechanical properties of a bioabsorbable fracture plate material. J Biomed Mater Res 1997;38:17-24
    • (1997) J Biomed Mater Res , vol.38 , pp. 17-24
    • Pietrzak, W.S.1    Sarver, D.R.2    Bianchini, S.D.3
  • 25
    • 0036867607 scopus 로고    scopus 로고
    • Mechanical characteristics of an absorbable copolymer internal fixation pin
    • Pietrzak WS, Caminear DS, Perns SV. Mechanical characteristics of an absorbable copolymer internal fixation pin. J Foot Ankle Surg 2002;41:379-388
    • (2002) J Foot Ankle Surg , vol.41 , pp. 379-388
    • Pietrzak, W.S.1    Caminear, D.S.2    Perns, S.V.3
  • 28
    • 33751411180 scopus 로고    scopus 로고
    • Fracture healing in the elderly patient
    • Gruber R, Koch H, Doll BA, et al. Fracture healing in the elderly patient. Exp Gerontol 2006;41:1808-11093
    • (2006) Exp Gerontol , vol.41 , pp. 1808-11093
    • Gruber, R.1    Koch, H.2    Doll, B.A.3
  • 30
    • 0036627094 scopus 로고    scopus 로고
    • Biomechanical testing of bioabsorbable cannulated screws for slipped capital femoral epiphysis fixation
    • Kroeber MW, Rovinsky D, Haskell A, et al. Biomechanical testing of bioabsorbable cannulated screws for slipped capital femoral epiphysis fixation. Orthopedics 2002;25:659-663 (Pubitemid 36395017)
    • (2002) Orthopedics , vol.25 , Issue.6 , pp. 659-663
    • Kroeber, M.W.1    Rovinsky, D.2    Haskell, A.3    Heilmann, M.4    Lotz, J.5    Otsuka, N.6
  • 31
    • 33748469704 scopus 로고    scopus 로고
    • Complications at screw removal in slipped capital femoral epiphysis treated by cannulated titanium screws
    • DOI 10.1007/s00402-006-0126-5
    • Ilchmann T, Parsch K. Complications at screw removal in slipped capital femoral epiphysis treated by cannulated titanium screws. Arch Orthop Trauma Surg 2006;126:359-363 (Pubitemid 44349255)
    • (2006) Archives of Orthopaedic and Trauma Surgery , vol.126 , Issue.6 , pp. 359-363
    • Ilchmann, T.1    Parsch, K.2
  • 32
    • 33750571524 scopus 로고    scopus 로고
    • Clinical outcome after transfixation of the epiphysis with Kirschner wires in unstable slipped capital femoral epiphysis
    • Seller K, Wild A, Westhoff B, et al. Clinical outcome after transfixation of the epiphysis with Kirschner wires in unstable slipped capital femoral epiphysis. Int Orthop 2006;30:342-347
    • (2006) Int Orthop , vol.30 , pp. 342-347
    • Seller, K.1    Wild, A.2    Westhoff, B.3
  • 33
    • 45549086432 scopus 로고    scopus 로고
    • Fixation of patellar tendon bone graft in reconstruction of patellar ligaments. Comparison of bioabsorbable and metal interference screws - Results of treatment
    • Plomicski J, Borcz K, Kwiatkowski K, et al. Fixation of patellar tendon bone graft in reconstruction of patellar ligaments. Comparison of bioabsorbable and metal interference screws - results of treatment. Ortop Traumatol Rehabil 2008;10:44-53
    • (2008) Ortop Traumatol Rehabil , vol.10 , pp. 44-53
    • Plomicski, J.1    Borcz, K.2    Kwiatkowski, K.3
  • 34
    • 85026147122 scopus 로고    scopus 로고
    • The influence of temperature on the degradation rate of LactoSorb copolymer
    • Pietrzak WS, Kumar M, Eppley BL. The influence of temperature on the degradation rate of LactoSorb copolymer. J Craniofac Surg 2003;14:176-183
    • (2003) J Craniofac Surg , vol.14 , pp. 176-183
    • Pietrzak, W.S.1    Kumar, M.2    Eppley, B.L.3
  • 35
    • 0031471499 scopus 로고    scopus 로고
    • Elevated temperature degradation of a 50:50 copolymer of PLA-PGA
    • DOI 10.1089/ten.1997.3.345
    • Agrawal CM, Huang D, Schmitz JP, et al. Elevated temperature degradation of a 50:50 copolymer of PLA-PGA. Tissue Eng 1997;3:345-352 (Pubitemid 28028630)
    • (1997) Tissue Engineering , vol.3 , Issue.4 , pp. 345-352
    • Agrawal, C.M.1    Huang, D.2    Schmitz, J.P.3    Athanasiou, K.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.