메뉴 건너뛰기




Volumn 300, Issue 1, 2009, Pages 83-89

Loop-mediated isothermal amplification targeting the apxIVA gene for detection of Actinobacillus pleuropneumoniae

Author keywords

Actinobacillus pleuropneumoniae; Detection; Field trial; Loop mediated isothermal amplification; Nested PCR

Indexed keywords

APXIVA TOXIN; BACTERIAL TOXIN; UNCLASSIFIED DRUG;

EID: 70349693869     PISSN: 03781097     EISSN: 15746968     Source Type: Journal    
DOI: 10.1111/j.1574-6968.2009.01779.x     Document Type: Article
Times cited : (21)

References (20)
  • 1
    • 0037009856 scopus 로고    scopus 로고
    • Detection of antibodies to Actinobacillus pleuropneumoniae serotype 12 in pig serum using a blocking enzyme-linked immunosorbent assay
    • DOI 10.1016/S0378-1135(02)00156-6, PII S0378113502001566
    • Andresen LO, Klausen J, Barfod K Sørensen V (2002) Detection of antibodies to Actinobacillus pleuropneumoniae serotype 12 in pig serum using a blocking enzyme-linked immunosorbent assay. Vet Microbiol 89 : 61 67. (Pubitemid 35246339)
    • (2002) Veterinary Microbiology , vol.89 , Issue.1 , pp. 61-67
    • Andresen, L.O.1    Klausen, J.2    Barfod, K.3    Sorensen, V.4
  • 2
    • 0035793929 scopus 로고    scopus 로고
    • Isolation of Actinobacillus pleuropneumoniae serotype 2 by immunomagnetic separation
    • Angen Ø, Heegaard PMH, Lavritsen DT Sørensen V (2001) Isolation of Actinobacillus pleuropneumoniae serotype 2 by immunomagnetic separation. Vet Microbiol 79 : 19 29.
    • (2001) Vet Microbiol , vol.79 , pp. 19-29
    • Angen Ø1    Heegaard, P.M.H.2    Lavritsen, D.T.3    Sørensen, V.4
  • 4
    • 53249095483 scopus 로고    scopus 로고
    • Reverse transcription loop-mediated isothermal amplification for the detection of highly pathogenic porcine reproductive and respiratory syndrome virus
    • Chen H, Zhang J, Sun D, Ma L, Liu X, Quan K Liu Y (2008) Reverse transcription loop-mediated isothermal amplification for the detection of highly pathogenic porcine reproductive and respiratory syndrome virus. J Virol Methods 153 : 266 268.
    • (2008) J Virol Methods , vol.153 , pp. 266-268
    • Chen, H.1    Zhang, J.2    Sun, D.3    Ma, L.4    Liu, X.5    Quan, K.6    Liu, Y.7
  • 5
    • 0035829398 scopus 로고    scopus 로고
    • Detection of Actinobacillus pleuropneumoniae in cultures from nasal and tonsillar swabs of pigs by a PCR assay based on the nucleotide sequence of a dsbE-like gene
    • Chiers K, Van Overbeke I, Donné E, Baele M, Ducatelle R, De Baere T Haesebrouck F (2001) Detection of Actinobacillus pleuropneumoniae in cultures from nasal and tonsillar swabs of pigs by a PCR assay based on the nucleotide sequence of a dsbE-like gene. Vet Microbiol 83 : 147 159.
    • (2001) Vet Microbiol , vol.83 , pp. 147-159
    • Chiers, K.1    Van Overbeke, I.2    Donné, E.3    Baele, M.4    Ducatelle, R.5    De Baere, T.6    Haesebrouck, F.7
  • 6
    • 0242509130 scopus 로고    scopus 로고
    • Evaluation and field validation of PCR tests for detection of Actinobacillus pleuropneumoniae in subclinically infected pigs
    • Fittipaldi N, Broes A, Harel J, Kobisch M Gottschalk M (2003) evaluation and field validation of PCR tests for detection of Actinobacillus pleuropneumoniae in subclinically infected pigs. J Clin Microbiol 41 : 5085 5093.
    • (2003) J Clin Microbiol , vol.41 , pp. 5085-5093
    • Fittipaldi, N.1    Broes, A.2    Harel, J.3    Kobisch, M.4    Gottschalk, M.5
  • 7
    • 0031964152 scopus 로고    scopus 로고
    • Development of an immunomagnetic method for selective isolation of Actinobacillus pleuropneumoniae serotype 1 from tonsils
    • Gagne A, Lacouture S, Broes A, D'Allaire S Gottschalk M (1998) Development of an immunomagnetic method for selective isolation of Actinobacillus pleuropneumoniae serotype 1 from tonsils. J Clin Microbiol 36 : 251 254.
    • (1998) J Clin Microbiol , vol.36 , pp. 251-254
    • Gagne, A.1    Lacouture, S.2    Broes, A.3    D'Allaire, S.4    Gottschalk, M.5
  • 8
    • 0031964649 scopus 로고    scopus 로고
    • Improved diagnostic PCR assay for Actinobacillus pleuropneumoniae based on the nucleotide sequence of an outer membrane lipoprotein
    • Gram T Ahrens P (1998) Improved diagnostic PCR assay for Actinobacillus pleuropneumoniae based on the nucleotide sequence of an outer membrane lipoprotein. J Clin Microbiol 36 : 443 448.
    • (1998) J Clin Microbiol , vol.36 , pp. 443-448
    • Gram, T.1    Ahrens, P.2
  • 9
    • 27744549435 scopus 로고    scopus 로고
    • Loop-mediated isothermal amplification for the rapid detection of Salmonella
    • Hara-Kudo Y, Yoshino M, Kojima T Ikedo M (2005) Loop-mediated isothermal amplification for the rapid detection of Salmonella. FEMS Microbiol Lett 253 : 155 161.
    • (2005) FEMS Microbiol Lett , vol.253 , pp. 155-161
    • Hara-Kudo, Y.1    Yoshino, M.2    Kojima, T.3    Ikedo, M.4
  • 10
    • 33846212368 scopus 로고    scopus 로고
    • Development of H5-RT-LAMP (loop-mediated isothermal amplification) system for rapid diagnosis of H5 avian influenza virus infection
    • Imai M, Ninomiya A, Minekawa H, Notomi T, Ishizaki T, Tashiro M Odagiri T (2006) Development of H5-RT-LAMP (loop-mediated isothermal amplification) system for rapid diagnosis of H5 avian influenza virus infection. Vaccine 24 : 6679 6682.
    • (2006) Vaccine , vol.24 , pp. 6679-6682
    • Imai, M.1    Ninomiya, A.2    Minekawa, H.3    Notomi, T.4    Ishizaki, T.5    Tashiro, M.6    Odagiri, T.7
  • 12
    • 0033041785 scopus 로고    scopus 로고
    • Identification of Actinobacillus pleuropneumoniae strains of serotypes 7 and 4 using monoclonal antibodies: Demonstration of common LPS O-chain epitopes with Actinobacillus lignieresii
    • Lebrun A, Lacouture S, Côté D, Mittal KR Gottschalk M (1999) Identification of Actinobacillus pleuropneumoniae strains of serotypes 7 and 4 using monoclonal antibodies: demonstration of common LPS O-chain epitopes with Actinobacillus lignieresii. Vet Microbiol 65 : 271 282.
    • (1999) Vet Microbiol , vol.65 , pp. 271-282
    • Lebrun, A.1    Lacouture, S.2    Côté, D.3    Mittal, K.R.4    Gottschalk, M.5
  • 14
    • 47249120814 scopus 로고    scopus 로고
    • Rapid and sensitive detection of Singapore grouper iridovirus by loop-mediated isothermal amplification
    • Mao XL, Zhou S, Xu D, Gong J, Cui HC Qin QW (2008) Rapid and sensitive detection of Singapore grouper iridovirus by loop-mediated isothermal amplification. J Appl Microbiol 105 : 389 397.
    • (2008) J Appl Microbiol , vol.105 , pp. 389-397
    • Mao, X.L.1    Zhou, S.2    Xu, D.3    Gong, J.4    Cui, H.C.5    Qin, Q.W.6
  • 15
    • 0344527886 scopus 로고    scopus 로고
    • Molecular cloning and sequencing of the aroA gene from Actinobacillus pleuropneumoniae and its use in a PCR assay for rapid identification
    • Moral CH, Soriano AC, Salazar MS, Marcos JY, Ramos SS Carrasco GN (1999) Molecular cloning and sequencing of the aroA gene from Actinobacillus pleuropneumoniae and its use in a PCR assay for rapid identification. J Clin Microbiol 37 : 1575 1578.
    • (1999) J Clin Microbiol , vol.37 , pp. 1575-1578
    • Moral, C.H.1    Soriano, A.C.2    Salazar, M.S.3    Marcos, J.Y.4    Ramos, S.S.5    Carrasco, G.N.6
  • 16
    • 2442610695 scopus 로고    scopus 로고
    • Real-time turbidimetry of LAMP reaction for quantifying template DNA
    • Mori Y, Kitao M, Tomita N Notomi T (2004) Real-time turbidimetry of LAMP reaction for quantifying template DNA. J Biochem Bioph Meth 59 : 145 157.
    • (2004) J Biochem Bioph Meth , vol.59 , pp. 145-157
    • Mori, Y.1    Kitao, M.2    Tomita, N.3    Notomi, T.4
  • 17
    • 0036599262 scopus 로고    scopus 로고
    • Accelerated reaction by loop-mediated isothermal amplification using loop primers
    • Nagamine K, Hase T Notomi T (2002) Accelerated reaction by loop-mediated isothermal amplification using loop primers. Mol Cell Probe 16 : 223 229.
    • (2002) Mol Cell Probe , vol.16 , pp. 223-229
    • Nagamine, K.1    Hase, T.2    Notomi, T.3
  • 20
    • 12844252042 scopus 로고    scopus 로고
    • Sensitive and rapid detection of Shigella and enteroinvasive Escherichia coli by a loop-mediated isothermal amplification method
    • Song T, Toma C, Nakasone N Iwanaga M (2005) Sensitive and rapid detection of Shigella and enteroinvasive Escherichia coli by a loop-mediated isothermal amplification method. FEMS Microbiol Lett 243 : 259 263.
    • (2005) FEMS Microbiol Lett , vol.243 , pp. 259-263
    • Song, T.1    Toma, C.2    Nakasone, N.3    Iwanaga, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.