Volumn 223, Issue 3, 2009, Pages 311-316

Effect of surface modification on surface properties and tribological behaviours of titanium alloys

Author keywords

Carburization; Ion implantation; Titanium alloys; Wear

Indexed keywords

CARBURIZATION; ELEMENT CONCENTRATIONS; FRICTION AND WEAR; MULTI-FUNCTIONAL; NITROGEN ION IMPLANTATIONS; SURFACE COMPONENTS; SURFACE HARDNESS; SURFACE MODIFICATION; SURFACE WETTABILITY; TRIBOLOGICAL BEHAVIOUR; WEAR; WEAR DEBRIS; WEAR MECHANISMS; XPS ANALYSIS;

EID: 70349675771     PISSN: 13506501     EISSN: None     Source Type: Journal    
DOI: 10.1243/13506501JET488     Document Type: Article
Times cited : (31)

References (14)
  • 1
    • 36148963270 scopus 로고    scopus 로고
    • Comparison of dry sliding friction and wear of Ti6Al4V alloy treated by plasma electro-lytic oxidation and PVD coating
    • L. Ceschini, E. Lanoni, C. Martini, D. Prandstraller, G. Sambogna, 'Comparison of dry sliding friction and wear of Ti6Al4V alloy treated by plasma electro-lytic oxidation and PVD coating' Wear 264 1-2 (2008): 86-95
    • (2008) Wear , vol.264 , Issue.1-2
    • Ceschini, L.1    Lanoni, E.2    Martini, C.3    Prandstraller, D.4    Sambogna, G.5
  • 2
    • 0032593534 scopus 로고    scopus 로고
    • Wear, corrosion and fatigue properties of ion implanted titanium alloy Ti6Al4V
    • H. Schmidt, H. E. Exner, 'Wear, corrosion and fatigue properties of ion implanted titanium alloy Ti6Al4V' Z. Metallkd. Int. J. Mater. Res. Adv. Tech. 90 8 (1999): 594-601
    • (1999) Z. Metallkd. Int. J. Mater. Res. Adv. Tech. , vol.90 , Issue.8
    • Schmidt, H.1    Exner, H.E.2
  • 3
    • 33846794882 scopus 로고    scopus 로고
    • Improvement of tribological behavior of a Ti-Al-V alloy by nitrogen ion implantation
    • Y. Z. Liu, X. T. Zu, S. Y. Qiu, X. Q. Huang, 'Improvement of tribological behavior of a Ti-Al-V alloy by nitrogen ion implantation' Rare Met. 25 (2006): 309-314
    • (2006) Rare Met. , vol.25
    • Liu, Y.Z.1    Zu, X.T.2    Qiu, S.Y.3    Huang, X.Q.4
  • 4
    • 0035081536 scopus 로고    scopus 로고
    • The fretting corrosion resistance of PVD surface-modified orthopedic implant alloys
    • J. A. Hendry, R. M. Pilliar, 'The fretting corrosion resistance of PVD surface-modified orthopedic implant alloys' J. Biomed. Mater. Res. 58 2 (2001): 156-166
    • (2001) J. Biomed. Mater. Res. , vol.58 , Issue.2
    • Hendry, J.A.1    Pilliar, R.M.2
  • 6
    • 0036508184 scopus 로고    scopus 로고
    • Chemical vapor deposition diamond thin films growth on Ti6AL4V using the surfatron system
    • A. F. Azevedo, E. J. Corat, N. F. Leite, V. J. Trava-Airoldi, 'Chemical vapor deposition diamond thin films growth on Ti6AL4V using the surfatron system' Diam. Relat. Mater. 11 3-6 (2002): 550-554
    • (2002) Diam. Relat. Mater. , vol.11 , Issue.3-6
    • Azevedo, A.F.1    Corat, E.J.2    Leite, N.F.3    Trava-Airoldi, V.J.4
  • 7
    • 33846536727 scopus 로고    scopus 로고
    • Hydroxyapatite coatings prepared by micro-arc oxidation in Ca- And P-containing electrolyte
    • J. F. Sun, Y. Han, X. Huang, 'Hydroxyapatite coatings prepared by micro-arc oxidation in Ca- and P-containing electrolyte' Surf. Coat. Technol. 201 9-11 (2007): 5655-5658
    • (2007) Surf. Coat. Technol. , vol.201 , Issue.9-11
    • Sun, J.F.1    Han, Y.2    Huang, X.3
  • 8
    • 3042728678 scopus 로고    scopus 로고
    • Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrate
    • R. M. Souto, M. M. Lemus, R. L. Reis, 'Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrate' J. Biomed. Mater. Res. 70A 1 (2004): 59-65
    • (2004) J. Biomed. Mater. Res. , vol.70 A , Issue.1
    • Souto, R.M.1    Lemus, M.M.2    Reis, R.L.3
  • 9
    • 0033657714 scopus 로고    scopus 로고
    • Compositional and microstructural changes of engineered plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrates during incubation in protein-free simulated body fluid
    • O. Grassmann, R. B. Heimann, 'Compositional and microstructural changes of engineered plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrates during incubation in protein-free simulated body fluid' J. Biomed. Mater. Res. 53 6 (2000): 685-693
    • (2000) J. Biomed. Mater. Res. , vol.53 , Issue.6
    • Grassmann, O.1    Heimann, R.B.2
  • 11
    • 2042439073 scopus 로고    scopus 로고
    • Formation of nanocrystalline TiC by a low-temperature route
    • L. Shi, Y. L Gu, L. H Chen, Z. H. Yang, J. H. Ma, Y. T. Qian, 'Formation of nanocrystalline TiC by a low-temperature route' Chem. Lett. 33 1 (2004): 56-57
    • (2004) Chem. Lett. , vol.33 , Issue.1
    • Shi, L.1    Gu, Y.L.2    Chen, L.H.3    Yang, Z.H.4    Ma, J.H.5    Qian, Y.T.6
  • 12
    • 84953679195 scopus 로고
    • Carbonaceous overlayers on Ru(001)
    • J. Hrbek, 'Carbonaceous overlayers on Ru(001)' J. Vac. Sci. Technol. A 4 1 (1986): 86-89
    • (1986) J. Vac. Sci. Technol. A , vol.4 , Issue.1
    • Hrbek, J.1
  • 13
    • 0027599754 scopus 로고
    • Cell-adhesion to plasma-treated polymer surfaces
    • DOI: 10.1016/0032-3861
    • Y. Tamada, Y. Ikada, 'Cell-adhesion to plasma-treated polymer surfaces' Polymer 34 10 (1993): 2208-2212 DOI: 10.1016/0032-3861
    • (1993) Polymer , vol.34 , Issue.10
    • Tamada, Y.1    Ikada, Y.2
  • 14
    • 33748946541 scopus 로고    scopus 로고
    • Effects of orthopaedic wear particles on osteoprogenitor cells
    • S. B. Goodman, T. Ma, R. Chiu, R. Ramachandran, R. L. Smith, 'Effects of orthopaedic wear particles on osteoprogenitor cells' Biomaterials 27 36 (2006): 6096-6101
    • (2006) Biomaterials , vol.27 , Issue.36
    • Goodman, S.B.1    Ma, T.2    Chiu, R.3    Ramachandran, R.4    Smith, R.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.