메뉴 건너뛰기




Volumn 62, Issue 10, 2009, Pages 920-923

Investigation of outpatients referred to a chemical pathologist with potential pseudohyperkalaemia

Author keywords

[No Author keywords available]

Indexed keywords

BILIRUBIN; CREATININE; HEMOGLOBIN; LACTATE DEHYDROGENASE; POTASSIUM;

EID: 70349673622     PISSN: 00219746     EISSN: 14724146     Source Type: Journal    
DOI: 10.1136/jcp.2008.062141     Document Type: Article
Times cited : (11)

References (12)
  • 1
    • 34247186443 scopus 로고    scopus 로고
    • Spurious hyperkalaemia
    • Smellie WS. Spurious hyperkalaemia. BMJ 2007;334:693-695
    • (2007) BMJ , vol.334 , pp. 693-695
    • Smellie, W.S.1
  • 3
    • 17844368326 scopus 로고    scopus 로고
    • In vitro and in vivo haemolysis and potassium measurement
    • Ismail A, Shingler W, Seneviratne J, et al. In vitro and in vivo haemolysis and potassium measurement. BMJ 2005;330:949.
    • (2005) BMJ , vol.330 , pp. 949
    • Ismail, A.1    Shingler, W.2    Seneviratne, J.3
  • 4
    • 18844368274 scopus 로고    scopus 로고
    • Establishing a practical blood platelet threshold to avoid reporting spurious potassium results due to thrombocytosis
    • DOI 10.1258/0004563053857761
    • Thurlow V, Ozevlat H, Jones SA, et al. Establishing a practical blood platelet threshold to avoid reporting spurious potassium results due to thrombocytosis. Ann Clin Biochem 2005;42:196-199 (Pubitemid 40694959)
    • (2005) Annals of Clinical Biochemistry , vol.42 , Issue.3 , pp. 196-199
    • Thurlow, V.1    Ozevlat, H.2    Jones, S.A.3    Bailey, I.R.4
  • 5
    • 0032803026 scopus 로고    scopus 로고
    • Serum potassium is unreliable as an estimate of in vivo plasma potassium
    • Hartland AJ, Neary RH. Serum potassium is unreliable as an estimate of in vivo plasma potassium. Clin Chem 1999;45:1091-1092 (Pubitemid 29340550)
    • (1999) Clinical Chemistry , vol.45 , Issue.7 , pp. 1091-1092
    • Hartland, A.J.1    Neary, R.H.2
  • 6
    • 0015952627 scopus 로고
    • A comparison of serum versus heparinized plasma for routine chemical tests
    • Lum G, Gambino SR. A comparison of serum versus heparinized plasma for routine chemical tests. Am J Clin Pathol 1974;61:108-113
    • (1974) Am J Clin Pathol , vol.61 , pp. 108-113
    • Lum, G.1    Gambino, S.R.2
  • 7
    • 0030993955 scopus 로고    scopus 로고
    • How to minimise factitious hyperkalaemia in blood samples from general practice
    • Johnston JD, Hawthorne SW. How to minimise factitious hyperkalaemia in blood samples from general practice. BMJ 1997;314:1200.
    • (1997) BMJ , vol.314 , pp. 1200
    • Johnston, J.D.1    Hawthorne, S.W.2
  • 8
    • 79959299699 scopus 로고    scopus 로고
    • Minimising factitious hyperkalaemia
    • Gourlay NJ, McArthur C. Minimising factitious hyperkalaemia. BMJ 1997;315:190.
    • (1997) BMJ , vol.315 , pp. 190
    • Gourlay, N.J.1    McArthur, C.2
  • 9
    • 55949131818 scopus 로고    scopus 로고
    • Spurious hyperkalaemia due to potassium-EDTA contamination: Common and not always easy to identify
    • Cornes MP, Ford C, Gama R. Spurious hyperkalaemia due to potassium-EDTA contamination: common and not always easy to identify. Ann Clin Biochem 2008;45:601-603
    • (2008) Ann Clin Biochem , vol.45 , pp. 601-603
    • Cornes, M.P.1    Ford, C.2    Gama, R.3
  • 10
    • 40449115732 scopus 로고    scopus 로고
    • How to use linear regression and correlation in quantitative method comparison studies
    • Twomey PJ, Kroll MH. How to use linear regression and correlation in quantitative method comparison studies. Int J Clin Pract 2008;62:529-538
    • (2008) Int J Clin Pract , vol.62 , pp. 529-538
    • Twomey, P.J.1    Kroll, M.H.2
  • 12
    • 84871639406 scopus 로고    scopus 로고
    • (accessed 9 January 2009)
    • Simple Interactive Statistical Analysis. Fisher's exact test. http://www.quantitativeskills.com/sisa/statistics/fisher.htm (accessed 9 January 2009).
    • Fisher's Exact Test


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.