메뉴 건너뛰기




Volumn 37, Issue 11, 2009, Pages 2266-2287

The use of finite element methods and genetic algorithms in search of an optimal fabric reinforced porous graft system

Author keywords

Adventitial reinforcement; Constitutive model; Diametric compliance; Numerical modeling; Optimization; Vascular mechanics; Vascular prosthesis

Indexed keywords

ADVENTITIAL REINFORCEMENT; DIAMETRIC COMPLIANCE; NUMERICAL MODELING; VASCULAR MECHANICS; VASCULAR PROSTHESIS;

EID: 70349661705     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/s10439-009-9771-5     Document Type: Article
Times cited : (14)

References (31)
  • 2
    • 0036740290 scopus 로고    scopus 로고
    • Effect of well defined dodecahedral porosity on inflammation and angiogenesis
    • 12296563 10.1097/00002480-200209000-00004 1:CAS:528:DC%2BD38XnvF2hsrk%3D
    • D. Bezuidenhout N. Davies P. Zilla 2002 Effect of well defined dodecahedral porosity on inflammation and angiogenesis ASAIO J. 48 465 71 12296563 10.1097/00002480-200209000-00004 1:CAS:528:DC%2BD38XnvF2hsrk%3D
    • (2002) ASAIO J. , vol.48 , pp. 465-71
    • Bezuidenhout, D.1    Davies, N.2    Zilla, P.3
  • 3
    • 0024156740 scopus 로고
    • The challenge of small diameter vascular grafts
    • 2978590
    • W.E. Burkel 1988 The challenge of small diameter vascular grafts Med. Prog. Technol. 14 165 175 2978590
    • (1988) Med. Prog. Technol. , vol.14 , pp. 165-175
    • Burkel, W.E.1
  • 4
    • 46349099663 scopus 로고    scopus 로고
    • The dosage dependence of vegf stimulation on scaffold neovascularisation
    • 18541296 10.1016/j.biomaterials.2008.05.007 1:CAS:528: DC%2BD1cXotFCitLo%3D
    • N. Davies S. Dobner D. Bezuidenhout C. Schmidt M. Beck A.H. Zisch P Zilla 2008 The dosage dependence of vegf stimulation on scaffold neovascularisation Biomaterials 29 3531 3538 18541296 10.1016/j.biomaterials.2008.05.007 1:CAS:528:DC%2BD1cXotFCitLo%3D
    • (2008) Biomaterials , vol.29 , pp. 3531-3538
    • Davies, N.1    Dobner, S.2    Bezuidenhout, D.3    Schmidt, C.4    Beck, M.5    Zisch, A.H.6    Zilla, P.7
  • 8
    • 0027262209 scopus 로고
    • Regulation of in vitro capillary tube formation by anti-intergrin antibodies
    • 8491784 10.1083/jcb.121.4.931 1:CAS:528:DyaK3sXktVGkur4%3D
    • J. Gamble L. Matthias G. Meyer P. Kaur G. Russ R. Faull M. Berndt M. Vadas 1993 Regulation of in vitro capillary tube formation by anti-intergrin antibodies J. Cell Biol. 121 931 943 8491784 10.1083/jcb.121.4.931 1:CAS:528:DyaK3sXktVGkur4%3D
    • (1993) J. Cell Biol. , vol.121 , pp. 931-943
    • Gamble, J.1    Matthias, L.2    Meyer, G.3    Kaur, P.4    Russ, G.5    Faull, R.6    Berndt, M.7    Vadas, M.8
  • 9
    • 0021799016 scopus 로고
    • Increased compliance near vascular anastomoses
    • DOI 10.1067/mva.1985.avs0020419
    • J.E. Hasson J. Megerman W.A. Abbott 1985 Increased compliance near vascular anastamosis J. Vasc. Surg. 2 419 423 3999232 10.1067/mva.1985. avs0020419 1:STN:280:DyaL2M3htFWitg%3D%3D (Pubitemid 15056190)
    • (1985) Journal of Vascular Surgery , vol.2 , Issue.3 , pp. 419-423
    • Hasson, J.E.1    Megerman, J.2    Abbott, W.M.3
  • 10
    • 0027690195 scopus 로고
    • Experimental approaches on measuring the mechanical properties and constitutive laws of arterial walls
    • 8302029 10.1115/1.2895528 1:STN:280:DyaK2c7jtlKnsw%3D%3D
    • K. Hayashi 1993 Experimental approaches on measuring the mechanical properties and constitutive laws of arterial walls J. Biomech. Eng. 115 481 487 8302029 10.1115/1.2895528 1:STN:280:DyaK2c7jtlKnsw%3D%3D
    • (1993) J. Biomech. Eng. , vol.115 , pp. 481-487
    • Hayashi, K.1
  • 11
    • 0018898430 scopus 로고
    • Stiffness and elastic behavior of human intracranial and extracranial arteries
    • DOI 10.1016/0021-9290(80)90191-8
    • K. Hayashi H. Handa S. Nagasawa A. Okumura K. Moritake 1980 Stiffness and elastic behavior of human intracranial and extracranial arteries J. Biomech. 13 175 184 7364778 10.1016/0021-9290(80)90191-8 1:STN:280:DyaL3c7mtVShtg%3D%3D (Pubitemid 10176474)
    • (1980) Journal of Biomechanics , vol.13 , Issue.2 , pp. 175-184
    • Hayashi, K.1    Handa, H.2    Nagasawa, S.3
  • 12
    • 0020818672 scopus 로고
    • The endothelialisation of a fibrous polyurethane microvascular prosthesis after implantation in the abdominal aorta of the rat
    • 1:STN:280:DyaL2c%2FovVSnsQ%3D%3D
    • F. Hess C. Jerusalem B. Braun 1983 The endothelialisation of a fibrous polyurethane microvascular prosthesis after implantation in the abdominal aorta of the rat J. Cardiovasc. Surg. 24 516 524 1:STN:280:DyaL2c%2FovVSnsQ%3D%3D
    • (1983) J. Cardiovasc. Surg. , vol.24 , pp. 516-524
    • Hess, F.1    Jerusalem, C.2    Braun, B.3
  • 13
    • 0027026645 scopus 로고
    • Engineering design of vascular prosthesis
    • 10.1243/PIME-PROC-1992-206-269-02 1:STN:280:DyaK3s7gtlequw%3D%3D
    • T.V. How R. Guidon S.K. Young 1992 Engineering design of vascular prosthesis Proc. Instn. Mech. Eng. [H] 206 61 71 10.1243/PIME-PROC-1992-206-269- 02 1:STN:280:DyaK3s7gtlequw%3D%3D
    • (1992) Proc. Instn. Mech. Eng. [H] , vol.206 , pp. 61-71
    • How, T.V.1    Guidon, R.2    Young, S.K.3
  • 14
    • 33744474034 scopus 로고    scopus 로고
    • Multiobjective optimization of tibial locking screw design using a genetic algorithm: Evaluation of mechanical performance
    • DOI 10.1002/jor.20088
    • C.-C. Hsu C.-K. Chao J.-L. Wang J. Lin 2006 Multiobjective optimization of tibial locking screw design using a genetic algorithm: evaluation of mechanical performance J. Orthop. Res. 24 908 916 16528743 10.1002/jor.20088 (Pubitemid 43804925)
    • (2006) Journal of Orthopaedic Research , vol.24 , Issue.5 , pp. 908-916
    • Hsu, C.-C.1    Chao, C.-K.2    Wang, J.-L.3    Lin, J.4
  • 15
    • 33751040927 scopus 로고    scopus 로고
    • A combined FEM/genetic algorithm for vascular soft tissue elasticity estimation
    • DOI 10.1007/s10558-006-9013-5
    • A.S. Khalil B.E. Bouma M.R. Kaazempur Mofrad 2006 A combined fem/genetic algorithm for vascular soft tissue elasticity estimation Cardiovas. Eng. 6 93 103 10.1007/s10558-006-9013-5 (Pubitemid 44756476)
    • (2006) Cardiovascular Engineering , vol.6 , Issue.3 , pp. 93-102
    • Khalil, A.S.1    Bouma, B.E.2    Kaazempur Mofrad, M.R.3
  • 17
    • 70349660316 scopus 로고
    • Cardiovascular Implants-Vascular Prosthesis. American National Standard Association for the Advancement of Medical Instrumentation
    • NN
    • NN. Cardiovascular Implants-Vascular Prosthesis. American National Standard Association for the Advancement of Medical Instrumentation, AAMI Standard Edition, 1994.
    • (1994) AAMI Standard Edition
  • 18
    • 70349667867 scopus 로고    scopus 로고
    • Cardiovascular Implants-Tubular Vascular Prosthesis
    • NN
    • NN. Cardiovascular Implants-Tubular Vascular Prosthesis. ISO International Standard 7198, 1998.
    • (1998) ISO International Standard , vol.7198
  • 19
    • 33746327131 scopus 로고    scopus 로고
    • Measures of agreement between computation and experiment: Validation metrics
    • DOI 10.1016/j.jcp.2006.03.037, PII S0021999106001860
    • W.L. Oberkampf M.F. Barone 2006 Measures of agreement between computation and experiment: validation metrics J. Comput. Phys. 217 5 36 10.1016/j.jcp.2006.03.037 (Pubitemid 44111681)
    • (2006) Journal of Computational Physics , vol.217 , Issue.1 , pp. 5-36
    • Oberkampf, W.L.1    Barone, M.F.2
  • 20
    • 19344369606 scopus 로고    scopus 로고
    • Biaxial elastic material properties of porcine coronary media and adventitia
    • DOI 10.1152/ajpheart.00648.2004
    • A. Pandit X. Lu C. Wang G.S. Kassab 2005 Biaxial elastic material properties of porcine coronary media and adventitia Am. J. Physiol. Heart Circ. Physiol. 288 H2581 H2587 15792993 10.1152/ajpheart.00648.2004 1:CAS:528:DC%2BD2MXlsVynsbw%3D (Pubitemid 40720633)
    • (2005) American Journal of Physiology - Heart and Circulatory Physiology , vol.288 , Issue.6
    • Pandit, A.1    Lu, X.2    Wang, C.3    Kassab, G.S.4
  • 21
    • 0018620693 scopus 로고
    • Effect of elasticty of prosthetic wall on patency of small-diameter arterial prosthesis
    • 538595 1:STN:280:DyaL3c7kvVSlsg%3D%3D
    • K.B. Seifert D. Albo H. Knowlton D.J. Lyman 1979 Effect of elasticty of prosthetic wall on patency of small-diameter arterial prosthesis Surg. Forum. 30 206 208 538595 1:STN:280:DyaL3c7kvVSlsg%3D%3D
    • (1979) Surg. Forum. , vol.30 , pp. 206-208
    • Seifert, K.B.1    Albo, D.2    Knowlton, H.3    Lyman, D.J.4
  • 22
    • 9744273095 scopus 로고    scopus 로고
    • Optimization of the sources in local hyperthermia using a combined finite element-genetic algorithm method
    • DOI 10.1080/02656730410001711664
    • N. Siauve L. Nicolas C. Vollaire C. Marchal 2004 Optimization of the sources in local hyperthermia using a combined finite element-genetic algorithm method Int. J. Hyperthermia 20 815 833 15764344 10.1080/02656730410001711664 1:STN:280:DC%2BD2M7jvFaqtw%3D%3D (Pubitemid 39585570)
    • (2004) International Journal of Hyperthermia , vol.20 , Issue.8 , pp. 815-833
    • Siauve, N.1    Nicolas, L.2    Vollaire, C.3    Marchal, C.4
  • 23
    • 0026832789 scopus 로고
    • Effects of vascular graft/natural artery compliance mismatch on pulsatile flow
    • 1564063 10.1016/0021-9290(92)90027-X 1:STN:280:DyaK383is1WgsA%3D%3D
    • S.F.C. Stewart D.J. Lyman 1992 Effects of vascular graft/natural artery compliance mismatch on pulsatile flow J. Biomech. 25 297 310 1564063 10.1016/0021-9290(92)90027-X 1:STN:280:DyaK383is1WgsA%3D%3D
    • (1992) J. Biomech. , vol.25 , pp. 297-310
    • Stewart, S.F.C.1    Lyman, D.J.2
  • 24
    • 0022440426 scopus 로고
    • ON MATERIAL REPRESENTATION AND CONSTITUTIVE BRANCHING IN FINITE COMPRESSIBLE ELASTICITY.
    • DOI 10.1016/0022-5096(86)90033-5
    • B. Storåkers 1986 On material representation and constitutive branching in finite compressible elasticity J. Mech. Phys. Solids 34 125 145 10.1016/0022-5096(86)90033-5 (Pubitemid 16507202)
    • (1986) Journal of the Mechanics and Physics of Solids , vol.34 , Issue.2 , pp. 125-145
    • Storakers, B.1
  • 25
    • 0033756028 scopus 로고    scopus 로고
    • Compliance properties of conduits used in vascular reconstruction
    • DOI 10.1046/j.1365-2168.2000.01566.x
    • N.R. Tai H.J. Salacinski A. Edwards G. Hamilton A.M. Seifalian 2000 Compliance properties of conduits used in vascular reconstruction Br. J. Surg. 87 1516 1524 11091239 10.1046/j.1365-2168.2000.01566.x 1:STN:280: DC%2BD3M%2FltFOitQ%3D%3D (Pubitemid 30819518)
    • (2000) British Journal of Surgery , vol.87 , Issue.11 , pp. 1516-1524
    • Tai, N.R.1    Salacinski, H.J.2    Edwards, A.3    Hamilton, G.4    Seifalian, A.M.5
  • 26
    • 0026128999 scopus 로고
    • Effect of soft segment chemistry on the biostability of segmented polyurethanes. I. in vitro oxidation
    • 2026639 10.1002/jbm.820250306 1:CAS:528:DyaK3MXitFCgtbs%3D
    • A. Takahara A.J. Coury R.W. Hergenrother S.L. Cooper 1991 Effect of soft segment chemistry on the biostability of segmented polyurethanes. I. In vitro oxidation J. Biomed. Mater. Res. 25 341 356 2026639 10.1002/jbm.820250306 1:CAS:528:DyaK3MXitFCgtbs%3D
    • (1991) J. Biomed. Mater. Res. , vol.25 , pp. 341-356
    • Takahara, A.1    Coury, A.J.2    Hergenrother, R.W.3    Cooper, S.L.4
  • 27
    • 0017082138 scopus 로고
    • The stress-strain relationship for the skin
    • 965417 10.1016/0021-9290(76)90107-X 1:STN:280:DyaE2s%2Fgs1ajtQ%3D%3D
    • P. Tong Y. C. Fung 1976 The stress-strain relationship for the skin J. Biomech. 9 649 657 965417 10.1016/0021-9290(76)90107-X 1:STN:280: DyaE2s%2Fgs1ajtQ%3D%3D
    • (1976) J. Biomech. , vol.9 , pp. 649-657
    • Tong, P.1    Fung, Y.C.2
  • 28
    • 33748417592 scopus 로고    scopus 로고
    • Three-dimensional mechanical properties of porcine coronary arteries: A validated two-layer model
    • DOI 10.1152/ajpheart.01323.2005
    • C. Wang M. Garcia X. Lu Y. Lanir G.S. Kassab 2006 Three-dimensional mechanical properties of porcine coronary arteries: a validated two-layer model Am. J. Physiol. Heart Circ. Physiol. 291 H1200 H1209 16582016 10.1152/ajpheart.01323.2005 1:CAS:528:DC%2BD28XhtVSksrjL (Pubitemid 44343664)
    • (2006) American Journal of Physiology - Heart and Circulatory Physiology , vol.291 , Issue.3
    • Wang, C.1    Garcia, M.2    Lu, X.3    Lanir, Y.4    Kassab, G.S.5
  • 29
    • 0030088149 scopus 로고    scopus 로고
    • Compliance and diameter mismatch affect the wall shear rate distribution near an end-to-end anastomosis
    • DOI 10.1016/0021-9290(95)00028-3
    • M.W. Weston K. Rhee J.M. Tarbell 1996 Compliance and diameter mismatch affect the wall shear rate distribution near end-to-end anastomosis J. Biomech. 29 187 198 8849812 10.1016/0021-9290(95)00028-3 1:STN:280:DyaK2s%2Fgt1Cltw%3D%3D (Pubitemid 26010599)
    • (1996) Journal of Biomechanics , vol.29 , Issue.2 , pp. 187-198
    • Weston, M.W.1    Rhee, K.2    Tarbell, J.M.3
  • 31
    • 34848836043 scopus 로고    scopus 로고
    • Prosthetic vascular grafts: Wrong models, wrong questions and no healing
    • DOI 10.1016/j.biomaterials.2007.07.017, PII S0142961207005510, Festschrift honouring Professor David F. Williams
    • P. Zilla D. Bezuidenhout P. Human 2007 Prosthetic vascular grafts: wrong models, wrong questions and no healing Biomaterials 28 5009 5027 17688939 10.1016/j.biomaterials.2007.07.017 1:CAS:528:DC%2BD2sXhtFalsrzM (Pubitemid 47489794)
    • (2007) Biomaterials , vol.28 , Issue.34 , pp. 5009-5027
    • Zilla, P.1    Bezuidenhout, D.2    Human, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.