메뉴 건너뛰기




Volumn 37, Issue 10, 2009, Pages 2841-2843

Editorial: Point-of-care glucose testing in critically ill patients: Visual logistics and a glycemic variability hypothesis

Author keywords

Bandwidth; Discrepant values; Erroneous results; Hypothesis; ISO 15197 guideline; Locally smoothed median absolute difference curve; Outcomes

Indexed keywords

GLUCOSE; INSULIN;

EID: 70349656113     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0b013e3181ad7927     Document Type: Editorial
Times cited : (5)

References (15)
  • 1
    • 70349659457 scopus 로고    scopus 로고
    • Accuracy of AccuCheck glucose measurements in intensive care patients
    • Meynaar IA, van Spreuwel M, Tangkau PL, et al: Accuracy of AccuCheck glucose measurements in intensive care patients. Crit Care Med 2009; 37:2691-2696
    • (2009) Crit Care Med , vol.37 , pp. 2691-2696
    • Meynaar, I.A.1    Van Spreuwel, M.2    Tangkau, P.L.3
  • 2
    • 38649115012 scopus 로고    scopus 로고
    • Evaluation of point-of-care glucose testing accuracy using locally-smoothed median absolute difference curves
    • Kost GJ, Tran NK, Abad VJ, Louie RF: Evaluation of point-of-care glucose testing accuracy using locally-smoothed median absolute difference curves. Clin Chim Acta 2008; 389: 31-39
    • (2008) Clin Chim Acta , vol.389 , pp. 31-39
    • Kost, G.J.1    Tran, N.K.2    Abad, V.J.3    Louie, R.F.4
  • 3
    • 57349154521 scopus 로고    scopus 로고
    • Assessing the performance of handheld glucose testing for critical care
    • Kost GJ, Tran NK, Louie RF, et al: Assessing the performance of handheld glucose testing for critical care. Diabetes Tech Ther 2008; 10:445-451
    • (2008) Diabetes Tech Ther , vol.10 , pp. 445-451
    • Kost, G.J.1    Tran, N.K.2    Louie, R.F.3
  • 4
    • 68549085484 scopus 로고    scopus 로고
    • Point-ofcare testing for underserved populations: LS MAD curves, glycemic variability, and the first global performance cooperative
    • Kost GJ, Tan NK, Sifontes JR, et al: Point-ofcare testing for underserved populations: LS MAD curves, glycemic variability, and the first global performance cooperative. Point of Care 2009; 8:45-52
    • (2009) Point of Care , vol.8 , pp. 45-52
    • Kost, G.J.1    Tan, N.K.2    Sifontes, J.R.3
  • 5
    • 0025044540 scopus 로고
    • Critical limits for urgent clinician notification at US medical centers
    • Kost GJ: Critical limits for urgent clinician notification at US medical centers. JAMA 1990; 263:704-707
    • (1990) JAMA , vol.263 , pp. 704-707
    • Kost, G.J.1
  • 6
    • 50449103607 scopus 로고    scopus 로고
    • Benefits and risks of tight glucose control in critically ill adults. A meta-analysis
    • Wiener RS, Wiener DC, Larson RL: Benefits and risks of tight glucose control in critically ill adults. A meta-analysis. JAMA 2008; 300: 933-944
    • (2008) JAMA , vol.300 , pp. 933-944
    • Wiener, R.S.1    Wiener, D.C.2    Larson, R.L.3
  • 7
    • 0031938405 scopus 로고    scopus 로고
    • Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care/hospital/ ambulatory patients in the United States and Canada
    • Kost GJ, Vu HT, Lee J, et al: Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care/hospital/ ambulatory patients in the United States and Canada. Crit Care Med 1998; 26:581-590
    • (1998) Crit Care Med , vol.26 , pp. 581-590
    • Kost, G.J.1    Vu, H.T.2    Lee, J.3
  • 8
    • 0035023293 scopus 로고    scopus 로고
    • Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing
    • Tang Z, Louie RF, Lee JH, et al: Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing. Crit Care Med 2001; 29:1062-1070
    • (2001) Crit Care Med , vol.29 , pp. 1062-1070
    • Tang, Z.1    Louie, R.F.2    Lee, J.H.3
  • 9
    • 49949108319 scopus 로고    scopus 로고
    • Glucose variability and mortality in patients with sepsis
    • Ali NA, O'Brien JM, Dungan K, et al: Glucose variability and mortality in patients with sepsis. Crit Care Med 2008; 36:2316-2321
    • (2008) Crit Care Med , vol.36 , pp. 2316-2321
    • Ali, N.A.1    O'Brien, J.M.2    Dungan, K.3
  • 10
    • 59449084457 scopus 로고    scopus 로고
    • Alterations in glucose homeostasis in the pediatric thorough care unit: Hyperglycemia and glucose variability are associated with increased mortality and morbidity
    • Hirshberg E, Larsen G, Van Duker H: Alterations in glucose homeostasis in the pediatric thorough care unit: Hyperglycemia and glucose variability are associated with increased mortality and morbidity. Pediatr Crit Care Med 2008; 9:361-366
    • (2008) Pediatr Crit Care Med , vol.9 , pp. 361-366
    • Hirshberg, E.1    Larsen, G.2    Van Duker, H.3
  • 11
    • 51649116707 scopus 로고    scopus 로고
    • Glucose variability Is associated with mortality in the surgical intensive care unit
    • Dossett LA, Cao H, Mowery NT, et al Glucose variability Is associated with mortality in the surgical intensive care unit. Am Surg 2008; 74:679-685
    • (2008) Am Surg , vol.74 , pp. 679-685
    • Dossett, L.A.1    Cao, H.2    Mowery, N.T.3
  • 12
    • 55349134410 scopus 로고    scopus 로고
    • Glycemic variability: A strong independent predictor of mortality in critically ill patients
    • Krinsley JS: Glycemic variability: A strong independent predictor of mortality in critically ill patients. Crit Care Med 2008; 36: 3008-3013
    • (2008) Crit Care Med , vol.36 , pp. 3008-3013
    • Krinsley, J.S.1
  • 13
    • 55349103078 scopus 로고    scopus 로고
    • The impact of the severity of sepsis on the risk of hypoglycaemia and glycaemic variability
    • Available at, Accessed August 14, 2009
    • Waeschle RM, Moerer O, Hilgers R, et al: The impact of the severity of sepsis on the risk of hypoglycaemia and glycaemic variability. Crit Care 2008; 12:R129. Available at: http:// ccforum.com/content/12/5/R129. Accessed August 14, 2009
    • (2008) Crit Care , vol.12
    • Waeschle, R.M.1    Moerer, O.2    Hilgers, R.3
  • 14
    • 33746621650 scopus 로고    scopus 로고
    • Variability of blood glucose concentration and short-term mortality in critically ill patients
    • Egi M, Bellomo R, Stachowski E, et al: Variability of blood glucose concentration and short-term mortality in critically ill patients. Anesthesiology 2006; 105:244-252
    • (2006) Anesthesiology , vol.105 , pp. 244-252
    • Egi, M.1    Bellomo, R.2    Stachowski, E.3
  • 15
    • 49949090661 scopus 로고    scopus 로고
    • Blood glucose concentration and outcome of critical illness: The impact of diabetes
    • Egi M, Bellomo R, Stachowski E, et al: Blood glucose concentration and outcome of critical illness: The impact of diabetes. Crit Care Med 2008; 36:2249-2255
    • (2008) Crit Care Med , vol.36 , pp. 2249-2255
    • Egi, M.1    Bellomo, R.2    Stachowski, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.