메뉴 건너뛰기




Volumn 45, Issue 6, 2009, Pages 378-380

Extreme multi-level percutaneous vertebroplasty for newly developed multiple adjacent compression fractures

Author keywords

Extreme multi level vertebropklasty compression fracture; Percutaneous vertebroplasty

Indexed keywords

CALCIUM CARBONATE; POLY(METHYL METHACRYLATE); RISEDRONIC ACID; VITAMIN D;

EID: 70349653763     PISSN: 20053711     EISSN: 15987876     Source Type: Journal    
DOI: 10.3340/jkns.2009.45.6.378     Document Type: Article
Times cited : (3)

References (11)
  • 1
    • 33646590937 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: Functional improvement in patients with osteoporotic compression fractures
    • Alvaréz L, Alcaraz M, Pérez-Higueras A, Granizo JJ, de Miguel I, Rossi RE, et al: Percutaneous vertebroplasty: functional improvement in patients with osteoporotic compression fractures. Spine 31: 1113-1118, 2006
    • (2006) Spine , vol.31 , pp. 1113-1118
    • Alvaréz, L.1    Alcaraz, M.2    Pérez-Higueras, A.3    Granizo, J.J.4    de Miguel, I.5    Rossi, R.E.6
  • 2
    • 0034655411 scopus 로고    scopus 로고
    • Percutaneous Vertebro plasty for Pain Relief and Spinal Stabilization
    • Barr JD, Barr MS, Lemley TJ, McCann RM: Percutaneous Vertebro plasty for Pain Relief and Spinal Stabilization. Spine 25: 923-928, 2000
    • (2000) Spine , vol.25 , pp. 923-928
    • Barr, J.D.1    Barr, M.S.2    Lemley, T.J.3    McCann, R.M.4
  • 3
    • 0035879117 scopus 로고    scopus 로고
    • The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior
    • Belkoff SM, Mathis JM, Jasper LE, Deramond H: The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior. Spine 26: 1537-1541, 2001
    • (2001) Spine , vol.26 , pp. 1537-1541
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3    Deramond, H.4
  • 4
    • 70349690267 scopus 로고    scopus 로고
    • Complication of the augmented vertebral body after percutaneous vertebroplasty in patients with osteoporotic compression fracture
    • Chun EO, Lee SG, Yoo CJ, Kim WK, Park CW, Lee U: Complication of the augmented vertebral body after percutaneous vertebroplasty in patients with osteoporotic compression fracture. J Korean Neurosurg Soc 34: 565-569,2003
    • (2003) J Korean Neurosurg Soc , vol.34 , pp. 565-569
    • Chun, E.O.1    Lee, S.G.2    Yoo, C.J.3    Kim, W.K.4    Park, C.W.5    Lee, U.6
  • 5
    • 14944341603 scopus 로고    scopus 로고
    • Incidence of subsequent vertebral fracture after kyphoplasty
    • discussion 2277
    • Fribourg D, Tang C, Sra P, Delamarter R, Bae H: Incidence of subsequent vertebral fracture after kyphoplasty. Spine 29: 2270-2276; discussion 2277, 2004
    • (2004) Spine , vol.29 , pp. 2270-2276
    • Fribourg, D.1    Tang, C.2    Sra, P.3    Delamarter, R.4    Bae, H.5
  • 7
    • 33749517928 scopus 로고    scopus 로고
    • Adjacent level load transfer following vertebral augmentation in the cadaveric spine
    • Kayanja MM, Evans K, Milks R, Lieberman IH: Adjacent level load transfer following vertebral augmentation in the cadaveric spine. Spine 31: E790-E797, 2006
    • (2006) Spine , vol.31
    • Kayanja, M.M.1    Evans, K.2    Milks, R.3    Lieberman, I.H.4
  • 8
    • 0035879306 scopus 로고    scopus 로고
    • Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty
    • Liebschner MA, Rosenberg WS, Keaveny TM: Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine 26: 1547-1554, 2001
    • (2001) Spine , vol.26 , pp. 1547-1554
    • Liebschner, M.A.1    Rosenberg, W.S.2    Keaveny, T.M.3
  • 9
    • 0038638438 scopus 로고    scopus 로고
    • The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty
    • Molloy S, Mathis JM, Belkoff SM: The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty. Spine 28: 1549-1554, 2003
    • (2003) Spine , vol.28 , pp. 1549-1554
    • Molloy, S.1    Mathis, J.M.2    Belkoff, S.M.3
  • 10
    • 66749116902 scopus 로고    scopus 로고
    • Epidural leakage of polymethymethacrylate following percutaneous vertebroplasty in the patients with osteoporotic vertebral compression fractures
    • Oh YK, Ryu KS, Park CK, Kang JK: Epidural leakage of polymethymethacrylate following percutaneous vertebroplasty in the patients with osteoporotic vertebral compression fractures. J Korean Neurosurg Soc 30: 319-324, 2001
    • (2001) J Korean Neurosurg Soc , vol.30 , pp. 319-324
    • Oh, Y.K.1    Ryu, K.S.2    Park, C.K.3    Kang, J.K.4
  • 11
    • 0037648845 scopus 로고    scopus 로고
    • The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: Finite-element analysis
    • Polikeit A, Nolte LP, Ferguson SJ: The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis. Spine 28: 991-996, 2003
    • (2003) Spine , vol.28 , pp. 991-996
    • Polikeit, A.1    Nolte, L.P.2    Ferguson, S.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.