메뉴 건너뛰기




Volumn 24, Issue 5, 2009, Pages 335-339

Effect of balloon inflation time on expansion of sirolimus-eluting stent

Author keywords

Angioplasty; Intravascular ultrasound; Restenosis; Stent

Indexed keywords

RAPAMYCIN;

EID: 70349651184     PISSN: 09108327     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00380-008-1130-1     Document Type: Article
Times cited : (17)

References (23)
  • 5
    • 5344265071 scopus 로고    scopus 로고
    • Usefulness of high-pressure post-dilatation to optimize deployment of drug-eluting stents for the treatment of diffuse instent coronary restenosis
    • Blackman DJ, Porto I, Shirodaria C, Channon KM, Banning AP (2004) Usefulness of high-pressure post-dilatation to optimize deployment of drug-eluting stents for the treatment of diffuse instent coronary restenosis. Am J Cardiol 94:922-925
    • (2004) Am J Cardiol , vol.94 , pp. 922-925
    • Blackman, D.J.1    Porto, I.2    Shirodaria, C.3    Channon, K.M.4    Banning, A.P.5
  • 7
    • 0035312809 scopus 로고    scopus 로고
    • American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS): A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    • Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, Pinto FJ, Rosenfield K, Siegel RJ, Tuzcu EM, Yock PG (2001) American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS): A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 37:1478-1492
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1478-1492
    • Mintz, G.S.1    Nissen, S.E.2    Anderson, W.D.3    Bailey, S.R.4    Erbel, R.5    Fitzgerald, P.J.6    Pinto, F.J.7    Rosenfield, K.8    Siegel, R.J.9    Tuzcu, E.M.10    Yock, P.G.11
  • 18
    • 48749129587 scopus 로고    scopus 로고
    • Determination of the minimum inflation time necessary for total stent expansion and apposition: An in vitro study
    • Trindade IS, Sarmento-Leite RE, Santos de Freitas M, Gottschall CA (2008) Determination of the minimum inflation time necessary for total stent expansion and apposition: An in vitro study. J Invasive Cardiol 20:396-398
    • (2008) J Invasive Cardiol , vol.20 , pp. 396-398
    • Trindade, I.S.1    Sarmento-Leite, R.E.2    Santos de Freitas, M.3    Gottschall, C.A.4
  • 21
    • 34249861075 scopus 로고    scopus 로고
    • Impact of post-dilatation with a focal expanding balloon for optimization of intracoronary stenting
    • Mori F, Tsurumi Y, Hagiwara N, Kasanuki H. (2007) Impact of post-dilatation with a focal expanding balloon for optimization of intracoronary stenting Heart Vessels 22:152-157
    • (2007) Heart Vessels , vol.22 , pp. 152-157
    • Mori, F.1    Tsurumi, Y.2    Hagiwara, N.3    Kasanuki, H.4
  • 23
    • 0028910358 scopus 로고
    • An explanation for discrepancy between angiographic and intravascular ultrasound measurements after percutaneous transluminal coronary angioplasty
    • Nakamura S, Mahon DJ, Maheswaran B, Gutfinger DE, Colombo A, Tobis JM (1995) An explanation for discrepancy between angiographic and intravascular ultrasound measurements after percutaneous transluminal coronary angioplasty. J Am Coll Cardiol 25:633-639
    • (1995) J Am Coll Cardiol , vol.25 , pp. 633-639
    • Nakamura, S.1    Mahon, D.J.2    Maheswaran, B.3    Gutfinger, D.E.4    Colombo, A.5    Tobis, J.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.