메뉴 건너뛰기




Volumn 9, Issue 8, 2009, Pages 6254-6260

Determination of glucose concentration in aqueous solution using ATR-WT-IR technique

Author keywords

ATR; Biosensors; Diabetes; Glucose monitoring; Infrared; Neural network; Noninvasive sensing; Wavelet

Indexed keywords

ATR; ATTENUATED TOTAL REFLECTANCE; FOURIER TRANSFORMATIONS; GLUCOSE MONITORING; NON-INVASIVE MONITORING; NON-INVASIVE SENSING; PEARSON'S CORRELATION COEFFICIENTS; WAVELET;

EID: 70349644297     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s90806254     Document Type: Article
Times cited : (4)

References (10)
  • 1
    • 0036233922 scopus 로고    scopus 로고
    • Continuous monitoring of blood glucose
    • Robert, J.J. Continuous monitoring of blood glucose. Hormone Res. 2002, 57, 81-84.
    • (2002) Hormone Res , vol.57 , pp. 81-84
    • Robert, J.J.1
  • 2
    • 57149086868 scopus 로고    scopus 로고
    • Assessing and advancing technology for the noninvasive measurement of clinical glucose
    • Bai, C.; Graham, T.L.; Arnold, M.A. Assessing and advancing technology for the noninvasive measurement of clinical glucose. Anal. Lett. 2008, 41, 2773-2793.
    • (2008) Anal. Lett. , vol.41 , pp. 2773-2793
    • Bai, C.1    Graham, T.L.2    Arnold, M.A.3
  • 3
    • 62649140020 scopus 로고    scopus 로고
    • Sensitive voltammetric sensor for determination of flumethasone pivalate, abused for doping by athletes
    • Goyal, R.N.; Chatterjee, S.; Bishnoi, S. Sensitive voltammetric sensor for determination of flumethasone pivalate, abused for doping by athletes. Sens. Actuat. B-Chem. 2009, 137, 676-680.
    • (2009) Sens. Actuat. B-Chem. , vol.137 , pp. 676-680
    • Goyal, R.N.1    Chatterjee, S.2    Bishnoi, S.3
  • 4
    • 36849043556 scopus 로고    scopus 로고
    • Development of membrane electrodes for selective determination of some antiepileptic drugs in pharmaceuticals, plasma and urine
    • Gupta, V.; Singh, A.; Gupta, B. Development of membrane electrodes for selective determination of some antiepileptic drugs in pharmaceuticals, plasma and urine. Anal. Bioanal. Chem. 2007, 389, 2019-2028.
    • (2007) Anal. Bioanal. Chem. , vol.389 , pp. 2019-2028
    • Gupta, V.1    Singh, A.2    Gupta, B.3
  • 5
    • 35448970489 scopus 로고    scopus 로고
    • Potentiometric sensors enabling fast screening of the benign prostatic hyperplasia drug alfuzosin in pharmaceuticals, urine and serum
    • Gupta, V.K.; Singh, A.K.; Gupta, B. Potentiometric sensors enabling fast screening of the benign prostatic hyperplasia drug alfuzosin in pharmaceuticals, urine and serum. Comb. Chem. High Throughput Screen 2007, 10, 560-570.
    • (2007) Comb. Chem. High Throughput Screen , vol.10 , pp. 560-570
    • Gupta, V.K.1    Singh, A.K.2    Gupta, B.3
  • 6
    • 43249123473 scopus 로고    scopus 로고
    • Influence of temperature on the precision of noninvasive glucose sensing by near-infrared spectroscopy
    • 68630Q:1-68630Q:10
    • Liu, R.; Chen, W.L.; Chen, Y.; Xu, K.X. Influence of temperature on the precision of noninvasive glucose sensing by near-infrared spectroscopy. Proc. SPIE 2008, 6863, 68630Q:1-68630Q:10.
    • (2008) Proc. SPIE , vol.6863
    • Liu, R.1    Chen, W.L.2    Chen, Y.3    Xu, K.X.4
  • 7
    • 62449126447 scopus 로고    scopus 로고
    • Glucose sensors: A review of current and emerging technology
    • Oliver, N.S.; Toumazou, C.; Cass, A.E.G.; Johnston, D.G. Glucose sensors: a review of current and emerging technology. Diabet. Med. 2009, 26, 197-210.
    • (2009) Diabet. Med. , vol.26 , pp. 197-210
    • Oliver, N.S.1    Toumazou, C.2    Cass, A.E.G.3    Johnston, D.G.4
  • 8
    • 58149113468 scopus 로고    scopus 로고
    • Noninvasive glycaemia monitoring: Background, traditional findings, and novelties in the recent clinical trials
    • Tura, A. Noninvasive glycaemia monitoring: background, traditional findings, and novelties in the recent clinical trials. Curr. Opin. Clin. Nutr. Metab. Care 2008, 11, 607-612.
    • (2008) Curr. Opin. Clin. Nutr. Metab. Care , vol.11 , pp. 607-612
    • Tura, A.1
  • 9
    • 34250617799 scopus 로고    scopus 로고
    • Mid-infrared laser measurements of aqueous glucose
    • Guo, B.; Wang, Y.; Wang, Y.; Le, H.Q. Mid-infrared laser measurements of aqueous glucose. J. Biomed. Opt. 2007, 12, 024005.
    • (2007) J. Biomed. Opt , vol.12 , pp. 024005
    • Guo, B.1    Wang, Y.2    Wang, Y.3    Le, H.Q.4
  • 10
    • 48349132736 scopus 로고    scopus 로고
    • Applications of infrared spectroscopy to biochemical, food, and agricultural processes
    • Hashimoto, A.; Kameoka, T. Applications of infrared spectroscopy to biochemical, food, and agricultural processes. Appl. Spectrosc. Rev. 2008, 43, 416-451.
    • (2008) Appl. Spectrosc. Rev. , vol.43 , pp. 416-451
    • Hashimoto, A.1    Kameoka, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.