-
1
-
-
34250713003
-
Myocardial first pass perfusion imaging with gadobutrol: Impact of parallel imaging algorithms on image quality and signal behavior
-
DOI 10.1097/RLI.0b013e3180383572, PII 0000442420070700000007
-
Theisen D, Wintersperger BJ, Huber A, Dietrich O, Reiser MF, Schonberg SO. Myocardial first pass perfusion imaging with gadobutrol: impact of parallel imaging algorithms on image quality and signal behavior. Invest Radiol 2007;42:522-528. (Pubitemid 46955247)
-
(2007)
Investigative Radiology
, vol.42
, Issue.7
, pp. 522-528
-
-
Theisen, D.1
Wintersperger, B.J.2
Huber, A.3
Dietrich, O.4
Reiser, M.F.5
Schonberg, S.O.6
-
2
-
-
34249340114
-
Parallel imaging for first-pass myocardial perfusion
-
DOI 10.1016/j.mri.2006.10.012, PII S0730725X06003109
-
Irwan R, Lubbers DD, van der Vleuten PA, Kappert P, Gotte MJ, Sijens PE. Parallel imaging for first-pass myocardial perfusion. Magn Reson Imaging 2007;25:678-683. (Pubitemid 46817796)
-
(2007)
Magnetic Resonance Imaging
, vol.25
, Issue.5
, pp. 678-683
-
-
Irwan, R.1
Lubbers, D.D.2
Van Der Vleuten, P.A.3
Kappert, P.4
Gotte, M.J.W.5
Sijens, P.E.6
-
3
-
-
0036263907
-
Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
-
DOI 10.1002/mrm.10171
-
Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210. (Pubitemid 34587412)
-
(2002)
Magnetic Resonance in Medicine
, vol.47
, Issue.6
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
4
-
-
33646684312
-
Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: Initial experience
-
Meckel S, Mekle R, Taschner C, Haller S, Scheffler K, Radue EW, Wetzel SG. Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experience. Neuroradiology 2006;48:291-299.
-
(2006)
Neuroradiology
, vol.48
, pp. 291-299
-
-
Meckel, S.1
Mekle, R.2
Taschner, C.3
Haller, S.4
Scheffler, K.5
Radue, E.W.6
Wetzel, S.G.7
-
5
-
-
28444471600
-
Parallel magnetic resonance imaging using the GRAPPA operator formalism
-
Griswold MA, Blaimer M, Breuer F, Heidemann RM, Mueller M, Jakob PM. Parallel magnetic resonance imaging using the GRAPPA operator formalism. Magn Reson Med 2005;54:1553-1556.
-
(2005)
Magn Reson Med
, vol.54
, pp. 1553-1556
-
-
Griswold, M.A.1
Blaimer, M.2
Breuer, F.3
Heidemann, R.M.4
Mueller, M.5
Jakob, P.M.6
-
6
-
-
0345016340
-
Auto-SENSE Perfusion Imaging of the Whole Human Heart
-
DOI 10.1002/jmri.10419
-
Kostler H, Sandstede JJ, Lipke C, Landschutz W, Beer M, Hahn D. Auto-SENSE perfusion imaging of the whole human heart. J Magn Reson Imaging 2003;18:702-708. (Pubitemid 37467271)
-
(2003)
Journal of Magnetic Resonance Imaging
, vol.18
, Issue.6
, pp. 702-708
-
-
Kostler, H.1
Sandstede, J.J.W.2
Lipke, C.3
Landschutz, W.4
Beer, M.5
Hahn, D.6
-
7
-
-
3543128963
-
UNFOLD-SENSE: A parallel MRI method with self-calibration and artifact suppression
-
DOI 10.1002/mrm.20133
-
Madore B. UNFOLD-SENSE: a parallel MRI method with self-calibration and artifact suppression. Magn Reson Med 2004;52:310-320. (Pubitemid 39025275)
-
(2004)
Magnetic Resonance in Medicine
, vol.52
, Issue.2
, pp. 310-320
-
-
Madore, B.1
-
8
-
-
0034794323
-
Advances in sensitivity encoding with arbitrary k-space trajectories
-
DOI 10.1002/mrm.1241
-
Pruessmann KP, Weiger M, Bornert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651. (Pubitemid 32906132)
-
(2001)
Magnetic Resonance in Medicine
, vol.46
, Issue.4
, pp. 638-651
-
-
Pruessmann, K.P.1
Weiger, M.2
Bornert, P.3
Boesiger, P.4
-
9
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
-
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999;42:952-962. (Pubitemid 29521486)
-
(1999)
Magnetic Resonance in Medicine
, vol.42
, Issue.5
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
10
-
-
0030203923
-
Perfusion imaging of the human brain at 1.5 T using a single-shot EPI spin tagging approach
-
Ye FQ, Pekar JJ, Jezzard P, Duyn J, Frank JA, McLaughlin AC. Perfusion imaging of the human brain at 1.5 T using a single-shot EPI spin tagging approach. Magn Reson Med 1996;36:217-224. (Pubitemid 26271741)
-
(1996)
Magnetic Resonance in Medicine
, vol.36
, Issue.2
, pp. 219-224
-
-
Ye, F.Q.1
Pekar, J.J.2
Jezzard, P.3
Duyn, J.4
Frank, J.A.5
McLaughlin, A.C.6
-
11
-
-
30344488447
-
Highly constrained backprojection for time-resolved MRI
-
DOI 10.1002/mrm.20772
-
Mistretta CA, Wieben O, Velikina J, Block W, Perry J, Wu Y, Johnson K. Highly constrained backprojection for time-resolved MRI. Magn Reson Med 2006;55:30-40. (Pubitemid 43062925)
-
(2006)
Magnetic Resonance in Medicine
, vol.55
, Issue.1
, pp. 30-40
-
-
Mistretta, C.A.1
Wieben, O.2
Velikina, J.3
Block, W.4
Perry, J.5
Wu, Y.6
Johnson, K.7
Wu, Y.8
-
13
-
-
70349628849
-
Myocardial perfusion MRI with sliding window and CG-HYPR
-
Ge L, Kino A, Berg N, Liu X, Mascheri N, Griswold MA, Larson A, Mistretta CA, Li D. Myocardial perfusion MRI with sliding window and CG-HYPR. In: Proc 16th Annual Meeting ISMRM, Toronto; 2008.
-
Proc 16th Annual Meeting ISMRM, Toronto; 2008
-
-
Ge, L.1
Kino, A.2
Berg, N.3
Liu, X.4
Mascheri, N.5
Griswold, M.A.6
Larson, A.7
Mistretta, C.A.8
Li, D.9
-
14
-
-
0032754594
-
Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
-
Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999;42: 963-969.
-
(1999)
Magn Reson Med
, vol.42
, pp. 963-969
-
-
Pipe, J.G.1
|