메뉴 건너뛰기




Volumn 192, Issue 1-3, 2009, Pages 94-97

Voltammetric determination of cocaine in confiscated samples using a cobalt hexacyanoferrate film-modified electrode

Author keywords

Chemically modified electrodes; Cobalt hexacyanoferrate; Cocaine; Forensic chemistry

Indexed keywords

ACETONITRILE; COBALT; COBALT HEXACYANOFERRATE; COCAINE; INORGANIC SALT; PLATINUM; SODIUM PERCHLORATE; UNCLASSIFIED DRUG;

EID: 70349610554     PISSN: 03790738     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.forsciint.2009.08.004     Document Type: Article
Times cited : (45)

References (23)
  • 2
    • 30944456491 scopus 로고    scopus 로고
    • Simultaneous analyses of cocaine, cocaethylene, and their possible metabolic and pyrolytic products
    • Cardona P.S., Chaturvedi A.K., Soper J.W., and Canfield D.V. Simultaneous analyses of cocaine, cocaethylene, and their possible metabolic and pyrolytic products. Forensic Sci. Int. 157 (2006) 46-56
    • (2006) Forensic Sci. Int. , vol.157 , pp. 46-56
    • Cardona, P.S.1    Chaturvedi, A.K.2    Soper, J.W.3    Canfield, D.V.4
  • 3
    • 0038077452 scopus 로고    scopus 로고
    • Further studies on spot test and microcrystal tests for identification of cocaine
    • Swiatko J., De Forest P.R., and Zedeck M.S. Further studies on spot test and microcrystal tests for identification of cocaine. J. Forensic Sci. 48 (2003) 581-585
    • (2003) J. Forensic Sci. , vol.48 , pp. 581-585
    • Swiatko, J.1    De Forest, P.R.2    Zedeck, M.S.3
  • 4
    • 0034608516 scopus 로고    scopus 로고
    • Segmental analysis for cocaine and metabolites by HPLC in hair of suspected drug overdose cases
    • Clauwaert K.M., Van Bocxlaer J.F., Lambert W.E., and De Leenheer A.P. Segmental analysis for cocaine and metabolites by HPLC in hair of suspected drug overdose cases. Forensic Sci. Int. 110 (2000) 157-166
    • (2000) Forensic Sci. Int. , vol.110 , pp. 157-166
    • Clauwaert, K.M.1    Van Bocxlaer, J.F.2    Lambert, W.E.3    De Leenheer, A.P.4
  • 5
    • 26844518056 scopus 로고    scopus 로고
    • False positives and false negatives with a cocaine-specific field test and modification of test protocol to reduce false decision
    • Tsumura Y., Mitome T., and Kimoto S. False positives and false negatives with a cocaine-specific field test and modification of test protocol to reduce false decision. Forensic Sci. Int. 155 (2005) 158-164
    • (2005) Forensic Sci. Int. , vol.155 , pp. 158-164
    • Tsumura, Y.1    Mitome, T.2    Kimoto, S.3
  • 6
    • 85168048217 scopus 로고    scopus 로고
    • Scientific working group for the analysis of seized drugs SWGDRUG, United States Department of Justice, Drug Enforcement Administration. 3rd Ed, pp
    • Scientific working group for the analysis of seized drugs (SWGDRUG) recommendations. United States Department of Justice - Drug Enforcement Administration. 3rd Ed., pp.14-16, 2007.
    • (2007) recommendations , pp. 14-16
  • 7
    • 0038380472 scopus 로고    scopus 로고
    • Electrochemical sensors: a powerful tool in analytical chemistry
    • Stradiotto N.R., Yamanaka H., and Zanoni M.V.B. Electrochemical sensors: a powerful tool in analytical chemistry. J. Bras. Chem. Soc. 14 (2003) 159-173
    • (2003) J. Bras. Chem. Soc. , vol.14 , pp. 159-173
    • Stradiotto, N.R.1    Yamanaka, H.2    Zanoni, M.V.B.3
  • 9
    • 2342654178 scopus 로고    scopus 로고
    • Studying electrode mechanism and analytical determination of cocaine and its metabolites at the mercury electrode using square-wave voltammetry
    • Pavlova V., Mirceski V., et al. Studying electrode mechanism and analytical determination of cocaine and its metabolites at the mercury electrode using square-wave voltammetry. Anal. Chim. Acta 512 (2004) 49-56
    • (2004) Anal. Chim. Acta , vol.512 , pp. 49-56
    • Pavlova, V.1    Mirceski, V.2
  • 10
    • 0242660389 scopus 로고    scopus 로고
    • In vivo interaction of cocaine with the dopamine transporter as measured by voltammetry
    • Greco P.G., and Garris P.A. In vivo interaction of cocaine with the dopamine transporter as measured by voltammetry. European J. Pharmacol. 479 (2003) 117-125
    • (2003) European J. Pharmacol. , vol.479 , pp. 117-125
    • Greco, P.G.1    Garris, P.A.2
  • 11
    • 0026344341 scopus 로고
    • In vivo voltammetric studies on release mechanisms for cocaine with gamma-butyrolactone
    • Broderick P.A. In vivo voltammetric studies on release mechanisms for cocaine with gamma-butyrolactone. Pharmacol. Biochem. Behav. 40 (1991) 969-975
    • (1991) Pharmacol. Biochem. Behav. , vol.40 , pp. 969-975
    • Broderick, P.A.1
  • 12
    • 0038431183 scopus 로고    scopus 로고
    • Voltammetric determination of cocaine microparticles
    • Komorsky-Lovric S., Gagic S., and Penovsky R. Voltammetric determination of cocaine microparticles. Electroanalysis 11 (1999) 120-123
    • (1999) Electroanalysis , vol.11 , pp. 120-123
    • Komorsky-Lovric, S.1    Gagic, S.2    Penovsky, R.3
  • 13
    • 84987566189 scopus 로고
    • Voltammetric determination of cocaine in confiscated samples
    • Fernandez-Abedul M.T., and Rodriguez J.R.B. Voltammetric determination of cocaine in confiscated samples. Electroanalysis 3 (1991) 409-412
    • (1991) Electroanalysis , vol.3 , pp. 409-412
    • Fernandez-Abedul, M.T.1    Rodriguez, J.R.B.2
  • 14
    • 0030598040 scopus 로고    scopus 로고
    • Flow injection analysis with amperometric detection of cocaine in confiscated samples
    • Fernandez-Abedul M.T., and Costa-Garcia A. Flow injection analysis with amperometric detection of cocaine in confiscated samples. Anal. Chim. Acta 328 (1996) 67-71
    • (1996) Anal. Chim. Acta , vol.328 , pp. 67-71
    • Fernandez-Abedul, M.T.1    Costa-Garcia, A.2
  • 16
    • 84987467001 scopus 로고
    • Electroanalysis with electrodes modified by inorganic films
    • Cox J.A., Jaworski R.K., and Kulesza P.J. Electroanalysis with electrodes modified by inorganic films. Electroanalysis 3 (1991) 869-877
    • (1991) Electroanalysis , vol.3 , pp. 869-877
    • Cox, J.A.1    Jaworski, R.K.2    Kulesza, P.J.3
  • 17
    • 33744986798 scopus 로고
    • Electrochemistry of polynuclear transition-metal cyanides-prussian blue and its analogues
    • Itaya K., Uchida I., and Neff V.D. Electrochemistry of polynuclear transition-metal cyanides-prussian blue and its analogues. Acc. Chem. Res 19 (1986) 162-168
    • (1986) Acc. Chem. Res , vol.19 , pp. 162-168
    • Itaya, K.1    Uchida, I.2    Neff, V.D.3
  • 18
    • 0033522883 scopus 로고    scopus 로고
    • Determination of glutathione in vivo by microdialysis using liquid chromatography with a cobalt hexacyanoferrate chemically modified electrode
    • Shi G.Y., Lu J.X., Xu F., Sun W.L., Jin L.T., Yamamoto K., Tao S.G., and Jin J.Y. Determination of glutathione in vivo by microdialysis using liquid chromatography with a cobalt hexacyanoferrate chemically modified electrode. Anal. Chim. Acta 391 (1999) 307-313
    • (1999) Anal. Chim. Acta , vol.391 , pp. 307-313
    • Shi, G.Y.1    Lu, J.X.2    Xu, F.3    Sun, W.L.4    Jin, L.T.5    Yamamoto, K.6    Tao, S.G.7    Jin, J.Y.8
  • 19
    • 0033516728 scopus 로고    scopus 로고
    • Enhanced stability and electrocatalytic activity of a ruthenium-modified cobalt-hexacyanoferrate film electrode
    • Cataldi T.R.I., De Benedetto G., and Bianchini A. Enhanced stability and electrocatalytic activity of a ruthenium-modified cobalt-hexacyanoferrate film electrode. J. Electroanal. Chem. 471 (1999) 42-47
    • (1999) J. Electroanal. Chem. , vol.471 , pp. 42-47
    • Cataldi, T.R.I.1    De Benedetto, G.2    Bianchini, A.3
  • 20
    • 0033826754 scopus 로고    scopus 로고
    • Voltammetric determination of persulfate anions using an electrode modified with a Prussian blue film
    • de Oliveira M.F., Mortimer R.J., and Stradiotto N.R. Voltammetric determination of persulfate anions using an electrode modified with a Prussian blue film. Microchem. J. 64 (2000) 155-159
    • (2000) Microchem. J. , vol.64 , pp. 155-159
    • de Oliveira, M.F.1    Mortimer, R.J.2    Stradiotto, N.R.3
  • 21
    • 18444381760 scopus 로고    scopus 로고
    • Flow injection amperometric determination of persulfate in cosmetic products using a Prussian Blue film-modified electrode
    • de Oliveira M.F., Saczk A.A., Neto J.A.G., Roldan P.S., and Stradiotto N.R. Flow injection amperometric determination of persulfate in cosmetic products using a Prussian Blue film-modified electrode. Sensors 3 (2003) 371-380
    • (2003) Sensors , vol.3 , pp. 371-380
    • de Oliveira, M.F.1    Saczk, A.A.2    Neto, J.A.G.3    Roldan, P.S.4    Stradiotto, N.R.5
  • 23
    • 0031075177 scopus 로고    scopus 로고
    • Investigations on the electrochemical behaviour of prussian blue films in acetonitrile
    • Jayalakshmi M., Gomathi H., and Rao G.P. Investigations on the electrochemical behaviour of prussian blue films in acetonitrile. Solar Energy Mater. Solar Cells 45 (1997) 201-209
    • (1997) Solar Energy Mater. Solar Cells , vol.45 , pp. 201-209
    • Jayalakshmi, M.1    Gomathi, H.2    Rao, G.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.