메뉴 건너뛰기




Volumn 3, Issue 4, 2009, Pages 914-923

Exercise and glucose metabolism in persons with diabetes mellitus: Perspectives on the role for continuous glucose monitoring

Author keywords

Blood glucose; Energy metabolism physiology; Hyperglycemia; Hypoglycemia; Physical activity; Self monitoring

Indexed keywords

AMBULATORY MONITORING; BLOOD GLUCOSE MONITORING; DIABETES MELLITUS; EXERCISE; GLUCOSE BLOOD LEVEL; HUMAN; METABOLISM; PHYSIOLOGY; REVIEW;

EID: 70349582248     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680900300439     Document Type: Review
Times cited : (98)

References (48)
  • 1
    • 33746447698 scopus 로고    scopus 로고
    • Physical activity/exercise and type 2 diabetes: A consensus statement from the American Diabetes Association
    • Sigal RJ, Kenny GP, Wasserman DH, Castaneda-Sceppa C, White RD. Physical activity/exercise and type 2 diabetes: a consensus statement from the American Diabetes Association. Diabetes Care. 2006;29(6):1433-8.
    • (2006) Diabetes Care , vol.29 , Issue.6 , pp. 1433-1438
    • Sigal, R.J.1    Kenny, G.P.2    Wasserman, D.H.3    Castaneda-Sceppa, C.4    White, R.D.5
  • 2
    • 0028065383 scopus 로고
    • Exercise in individuals with IDDM
    • Wasserman DH, Zinman B. Exercise in individuals with IDDM. Diabetes Care. 1994;17(8):924-37.
    • (1994) Diabetes Care , vol.17 , Issue.8 , pp. 924-937
    • Wasserman, D.H.1    Zinman, B.2
  • 3
    • 77950800793 scopus 로고    scopus 로고
    • Physical activity and diabetes. Canadian Diabetes Association Clinical Practice Guidelines Expert Committee. Canadian Diabetes Association 2008 clinical practice guidelines for the prevention and management of diabetes in Canada
    • Sigal R, Kenny G, Oh P, Perkins BA, Plotnikoff RC, Prud'homme D, Riddell MC. Physical activity and diabetes. Canadian Diabetes Association Clinical Practice Guidelines Expert Committee. Canadian Diabetes Association 2008 clinical practice guidelines for the prevention and management of diabetes in Canada. Can J Diab. 2008;32(1):S37-9.
    • (2008) Can J Diab , vol.32 , Issue.1
    • Sigal, R.1    Kenny, G.2    Oh, P.3    Perkins, B.A.4    Plotnikoff, R.C.5    Prud'Homme, D.6    Riddell, M.C.7
  • 4
    • 0028954348 scopus 로고
    • Athletes with IDDM exhibit impaired metabolic control and increased lipid utilization with no increase in insulin sensitivity
    • Ebeling P, Tuominen JA, Bourey R, Koranyi L, Koivisto VA. Athletes with IDDM exhibit impaired metabolic control and increased lipid utilization with no increase in insulin sensitivity. Diabetes. 1995;44(4):471-7.
    • (1995) Diabetes , vol.44 , Issue.4 , pp. 471-477
    • Ebeling, P.1    Tuominen, J.A.2    Bourey, R.3    Koranyi, L.4    Koivisto, V.A.5
  • 5
    • 59249091586 scopus 로고    scopus 로고
    • Barriers to physical activity among patients with type 1 diabetes
    • Brazeau AS, Rabasa-Lhoret R, Strychar I, Mircescu H. Barriers to physical activity among patients with type 1 diabetes. Diabetes Care. 2008;31(11):2108-9.
    • (2008) Diabetes Care , vol.31 , Issue.11 , pp. 2108-2109
    • Brazeau, A.S.1    Rabasa-Lhoret, R.2    Strychar, I.3    Mircescu, H.4
  • 6
    • 33646707476 scopus 로고    scopus 로고
    • Physical activity, sport, and pediatric diabetes
    • Riddell MC, Iscoe KE. Physical activity, sport, and pediatric diabetes. Pediatr Diabetes. 2006;7(1):60-70.
    • (2006) Pediatr Diabetes , vol.7 , Issue.1 , pp. 60-70
    • Riddell, M.C.1    Iscoe, K.E.2
  • 7
    • 33748777150 scopus 로고    scopus 로고
    • Type 1 diabetes and exercise. Part II: Using the insulin pump to maximum advantage
    • Perkins BA, Riddell MC. Type 1 diabetes and exercise. Part II: using the insulin pump to maximum advantage. Can J Diab. 2006;30:72-80.
    • (2006) Can J Diab , vol.30 , pp. 72-80
    • Perkins, B.A.1    Riddell, M.C.2
  • 8
    • 33748799184 scopus 로고    scopus 로고
    • Type 1 diabetes and exercise. Part I: Applications of exercise physiology to patient management during vigorous activity
    • Riddell MC, Perkins BA. Type 1 diabetes and exercise. Part I: applications of exercise physiology to patient management during vigorous activity. Can J Diab. 2006;30:63-71.
    • (2006) Can J Diab , vol.30 , pp. 63-71
    • Riddell, M.C.1    Perkins, B.A.2
  • 12
    • 12344294864 scopus 로고    scopus 로고
    • Glucoregulation during and after exercise in health and insulin-dependent diabetes
    • Camacho RC, Galassetti P, Davis SN, Wasserman DH. Glucoregulation during and after exercise in health and insulin-dependent diabetes. Exerc Sport Sci Rev. 2005;33(1):17-23.
    • (2005) Exerc Sport Sci Rev , vol.33 , Issue.1 , pp. 17-23
    • Camacho, R.C.1    Galassetti, P.2    Davis, S.N.3    Wasserman, D.H.4
  • 15
    • 0028925177 scopus 로고
    • The reliability and repeatability of the blood glucose response to prolonged exercise in adolescent boys with IDDM
    • Temple MY, Bar-Or O, Riddell MC. The reliability and repeatability of the blood glucose response to prolonged exercise in adolescent boys with IDDM. Diabetes Care. 1995;18(3):326-32.
    • (1995) Diabetes Care , vol.18 , Issue.3 , pp. 326-332
    • Temple, M.Y.1    Bar-Or, O.2    Riddell, M.C.3
  • 16
    • 0027984216 scopus 로고
    • Hyperinsulinemia prevents prolonged hyperglycemia after intense exercise in insulin-dependent diabetic subjects
    • Sigal RJ, Purdon C, Fisher SJ, Halter JB, Vranic M, Marliss EB. Hyperinsulinemia prevents prolonged hyperglycemia after intense exercise in insulin-dependent diabetic subjects. J Clin Endocrinol Metab. 1994;79(4):1049-57.
    • (1994) J Clin Endocrinol Metab , vol.79 , Issue.4 , pp. 1049-1057
    • Sigal, R.J.1    Purdon, C.2    Fisher, S.J.3    Halter, J.B.4    Vranic, M.5    Marliss, E.B.6
  • 17
    • 0036315611 scopus 로고    scopus 로고
    • Intense exercise has unique effects on both insulin release and its roles in glucoregulation: Implications for diabetes
    • Marliss EB, Vranic M. Intense exercise has unique effects on both insulin release and its roles in glucoregulation: implications for diabetes. Diabetes. 2002;51 Suppl 1:S271-83.
    • (2002) Diabetes , vol.51 , Issue.SUPPL. 1
    • Marliss, E.B.1    Vranic, M.2
  • 18
    • 36048944072 scopus 로고    scopus 로고
    • New insights into managing the risk of hypoglycaemia associated with intermittent high-intensity exercise in individuals with type 1 diabetes mellitus: Implications for existing guidelines
    • Guelfi KJ, Jones TW, Fournier PA. New insights into managing the risk of hypoglycaemia associated with intermittent high-intensity exercise in individuals with type 1 diabetes mellitus: implications for existing guidelines. Sports Med. 2007;37(11):937-46.
    • (2007) Sports Med , vol.37 , Issue.11 , pp. 937-946
    • Guelfi, K.J.1    Jones, T.W.2    Fournier, P.A.3
  • 19
    • 33947518764 scopus 로고    scopus 로고
    • Glucose requirements to maintain euglycemia after moderate-intensity afternoon exercise in adolescents with type 1 diabetes are increased in a biphasic manner
    • McMahon SK, Ferreira LD, Ratnam N, Davey RJ, Youngs LM, Davis EA, Fournier PA, Jones TW. Glucose requirements to maintain euglycemia after moderate-intensity afternoon exercise in adolescents with type 1 diabetes are increased in a biphasic manner. J Clin Endocrinol Metab. 2007;92(3):963-8.
    • (2007) J Clin Endocrinol Metab , vol.92 , Issue.3 , pp. 963-968
    • McMahon, S.K.1    Ferreira, L.D.2    Ratnam, N.3    Davey, R.J.4    Youngs, L.M.5    Davis, E.A.6    Fournier, P.A.7    Jones, T.W.8
  • 20
    • 1842832105 scopus 로고    scopus 로고
    • Evidence for a vicious cycle of exercise and hypoglycemia in type 1 diabetes mellitus
    • Ertl AC, Davis SN. Evidence for a vicious cycle of exercise and hypoglycemia in type 1 diabetes mellitus. Diabetes Metab Res Rev. 2004;20(2):124-30.
    • (2004) Diabetes Metab Res Rev , vol.20 , Issue.2 , pp. 124-130
    • Ertl, A.C.1    Davis, S.N.2
  • 22
    • 41149140808 scopus 로고    scopus 로고
    • The nuts and bolts of achieving end points with real-time continuous glucose monitoring
    • Wolpert HA. The nuts and bolts of achieving end points with real-time continuous glucose monitoring. Diabetes Care. 2008;31 Suppl 2:S146-9.
    • (2008) Diabetes Care , vol.31 , Issue.SUPPL. 2
    • Wolpert, H.A.1
  • 24
    • 27644587693 scopus 로고    scopus 로고
    • The original Clarke Error Grid Analysis (EGA)
    • Clarke WL. The original Clarke Error Grid Analysis (EGA). Diabetes Technol Ther. 2005;7(5):776-9.
    • (2005) Diabetes Technol Ther , vol.7 , Issue.5 , pp. 776-779
    • Clarke, W.L.1
  • 25
    • 25644435718 scopus 로고    scopus 로고
    • Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis
    • Clarke WL, Anderson S, Farhy L, Breton M, Gonder-Frederick L, Cox D, Kovatchev B. Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis. Diabetes Care. 2005;28(10):2412-7.
    • (2005) Diabetes Care , vol.28 , Issue.10 , pp. 2412-2417
    • Clarke, W.L.1    Anderson, S.2    Farhy, L.3    Breton, M.4    Gonder-Frederick, L.5    Cox, D.6    Kovatchev, B.7
  • 26
    • 0036728499 scopus 로고    scopus 로고
    • Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type 1 diabetes
    • McGowan K, Thomas W, Moran A. Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type 1 diabetes. Diabetes Care. 2002;25(9):1499-503.
    • (2002) Diabetes Care , vol.25 , Issue.9 , pp. 1499-1503
    • McGowan, K.1    Thomas, W.2    Moran, A.3
  • 27
    • 48649110903 scopus 로고    scopus 로고
    • Comparison of the numerical and clinical accuracy of four continuous glucose monitors
    • Kovatchev B, Anderson S, Heinemann L, Clarke W. Comparison of the numerical and clinical accuracy of four continuous glucose monitors. Diabetes Care. 2008;31(6):1160-4.
    • (2008) Diabetes Care , vol.31 , Issue.6 , pp. 1160-1164
    • Kovatchev, B.1    Anderson, S.2    Heinemann, L.3    Clarke, W.4
  • 28
    • 0242300559 scopus 로고    scopus 로고
    • Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    • Boyne MS, Silver DM, Kaplan J, Saudek CD. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes. 2003;52(11):2790-4.
    • (2003) Diabetes , vol.52 , Issue.11 , pp. 2790-2794
    • Boyne, M.S.1    Silver, D.M.2    Kaplan, J.3    Saudek, C.D.4
  • 30
    • 44649124731 scopus 로고    scopus 로고
    • The effect of continuous subcutaneous glucose monitoring (CGMS) versus intermittent whole blood finger-stick glucose monitoring (SBGM) on hemoglobin A1c (HBA1c) levels in type I diabetic patients: A systematic review
    • Chetty VT, Almulla A, Odueyungbo A, Thabane L. The effect of continuous subcutaneous glucose monitoring (CGMS) versus intermittent whole blood finger-stick glucose monitoring (SBGM) on hemoglobin A1c (HBA1c) levels in type I diabetic patients: a systematic review. Diabetes Res Clin Pract. 2008;81(1):79-87.
    • (2008) Diabetes Res Clin Pract , vol.81 , Issue.1 , pp. 79-87
    • Chetty, V.T.1    Almulla, A.2    Odueyungbo, A.3    Thabane, L.4
  • 31
    • 33644875792 scopus 로고    scopus 로고
    • Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: A randomized controlled trial
    • Garg S, Zisser H, Schwartz S, Bailey T, Kaplan R, Ellis S, Jovanovic L. Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. Diabetes Care. 2006;29(1):44-50.
    • (2006) Diabetes Care , vol.29 , Issue.1 , pp. 44-50
    • Garg, S.1    Zisser, H.2    Schwartz, S.3    Bailey, T.4    Kaplan, R.5    Ellis, S.6    Jovanovic, L.7
  • 32
    • 34250776500 scopus 로고    scopus 로고
    • Reduction in hemoglobin A1C with real-time continuous glucose monitoring: Results from a 12-week observational study
    • Bailey TS, Zisser HC, Garg SK. Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study. Diabetes Technol Ther. 2007;9(3):203-10.
    • (2007) Diabetes Technol Ther , vol.9 , Issue.3 , pp. 203-210
    • Bailey, T.S.1    Zisser, H.C.2    Garg, S.K.3
  • 34
    • 33845483509 scopus 로고    scopus 로고
    • Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring
    • Deiss D, Bolinder J, Riveline JP, Battelino T, Bosi E, Tubiana-Rufi N, Kerr D, Phillip M. Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care. 2006;29(12):2730-2.
    • (2006) Diabetes Care , vol.29 , Issue.12 , pp. 2730-2732
    • Deiss, D.1    Bolinder, J.2    Riveline, J.P.3    Battelino, T.4    Bosi, E.5    Tubiana-Rufi, N.6    Kerr, D.7    Phillip, M.8
  • 35
    • 33645455629 scopus 로고    scopus 로고
    • Results of a randomised controlled cross-over trial on the effect of continuous subcutaneous glucose monitoring (CGMS) on glycaemic control in children and adolescents with type 1 diabetes
    • Deiss D, Hartmann R, Schmidt J, Kordonouri O. Results of a randomised controlled cross-over trial on the effect of continuous subcutaneous glucose monitoring (CGMS) on glycaemic control in children and adolescents with type 1 diabetes. Exp Clin Endocrinol Diabetes. 2006;114(2):63-7.
    • (2006) Exp Clin Endocrinol Diabetes , vol.114 , Issue.2 , pp. 63-67
    • Deiss, D.1    Hartmann, R.2    Schmidt, J.3    Kordonouri, O.4
  • 37
    • 4344582891 scopus 로고    scopus 로고
    • Use of the noninvasive GlucoWatch Biographer during exercise of varying intensity
    • Nunnold T, Colberg SR, Herriott MT, Somma CT. Use of the noninvasive GlucoWatch Biographer during exercise of varying intensity. Diabetes Technol Ther. 2004;6(4):454-62.
    • (2004) Diabetes Technol Ther , vol.6 , Issue.4 , pp. 454-462
    • Nunnold, T.1    Colberg, S.R.2    Herriott, M.T.3    Somma, C.T.4
  • 38
    • 18244363900 scopus 로고    scopus 로고
    • Function of the GlucoWatch G2 Biographer during exercise
    • Diabetes Research in Children Network (DirecNet) Study Group
    • Tsalikian E, Beck RW, Kalajian A, Janz KF, Tansey MJ, Diabetes Research in Children Network (DirecNet) Study Group. Function of the GlucoWatch G2 Biographer during exercise. Diabetes Technol Ther. 2005;7(1):230.
    • (2005) Diabetes Technol Ther , vol.7 , Issue.1 , pp. 230
    • Tsalikian, E.1    Beck, R.W.2    Kalajian, A.3    Janz, K.F.4    Tansey, M.J.5
  • 39
    • 33845337991 scopus 로고    scopus 로고
    • Efficacy of continuous real-time blood glucose monitoring during and after prolonged high-intensity cycling exercise: Spinning with a continuous glucose monitoring system
    • Iscoe KE, Campbell JE, Jamnik V, Perkins BA, Riddell MC. Efficacy of continuous real-time blood glucose monitoring during and after prolonged high-intensity cycling exercise: spinning with a continuous glucose monitoring system. Diabetes Technol Ther. 2006;8(6):627-35.
    • (2006) Diabetes Technol Ther , vol.8 , Issue.6 , pp. 627-635
    • Iscoe, K.E.1    Campbell, J.E.2    Jamnik, V.3    Perkins, B.A.4    Riddell, M.C.5
  • 41
    • 33750605755 scopus 로고    scopus 로고
    • Effect of exercise-mediated acidosis on determination of glycemia using CGMS
    • Davey RJ, Ferreira LD, Jones TW, Fournier PA. Effect of exercise-mediated acidosis on determination of glycemia using CGMS. Diabetes Technol Ther. 2006;8(4):516-8.
    • (2006) Diabetes Technol Ther , vol.8 , Issue.4 , pp. 516-518
    • Davey, R.J.1    Ferreira, L.D.2    Jones, T.W.3    Fournier, P.A.4
  • 42
    • 70349458061 scopus 로고    scopus 로고
    • The benefits of continuous glucose monitoring and a glucose monitoring schedule in individuals with type 1 diabetes during recreational diving
    • Adolfsson P, Örnhagen H, Jendle J. The benefits of continuous glucose monitoring and a glucose monitoring schedule in individuals with type 1 diabetes during recreational diving. J Diabetes Sci Technol. 2008;2(5):778-84.
    • (2008) J Diabetes Sci Technol , vol.2 , Issue.5 , pp. 778-784
    • Adolfsson, P.1    Örnhagen, H.2    Jendle, J.3
  • 43
    • 33748783797 scopus 로고    scopus 로고
    • Accuracy of continuous subcutaneous glucose monitoring with the GlucoDay in type 1 diabetic patients treated by subcutaneous insulin infusion during exercise of low versus high intensity
    • Fayolle C, Brun JF, Bringer J, Mercier J, Renard E. Accuracy of continuous subcutaneous glucose monitoring with the GlucoDay in type 1 diabetic patients treated by subcutaneous insulin infusion during exercise of low versus high intensity. Diabetes Metab. 2006;32(4):313-20.
    • (2006) Diabetes Metab , vol.32 , Issue.4 , pp. 313-320
    • Fayolle, C.1    Brun, J.F.2    Bringer, J.3    Mercier, J.4    Renard, E.5
  • 45
    • 43049180003 scopus 로고    scopus 로고
    • Continuous glucose monitoring counseling improves physical activity behaviors of individuals with type 2 diabetes: A randomized clinical trial
    • Allen NA, Fain JA, Braun B, Chipkin SR. Continuous glucose monitoring counseling improves physical activity behaviors of individuals with type 2 diabetes: a randomized clinical trial. Diabetes Res Clin Pract. 2008;80(3):371-9.
    • (2008) Diabetes Res Clin Pract , vol.80 , Issue.3 , pp. 371-379
    • Allen, N.A.1    Fain, J.A.2    Braun, B.3    Chipkin, S.R.4
  • 48
    • 53649105876 scopus 로고    scopus 로고
    • High rates of nocturnal hypoglycemia in a unique sports camp for athletes with type 1 diabetes: Lessons learned from continuous glucose monitoring systems
    • Iscoe KE, Corcoran M, Riddell MC. High rates of nocturnal hypoglycemia in a unique sports camp for athletes with type 1 diabetes: lessons learned from continuous glucose monitoring systems. Can J Diab. 2008;32(3):182-98.
    • (2008) Can J Diab , vol.32 , Issue.3 , pp. 182-198
    • Iscoe, K.E.1    Corcoran, M.2    Riddell, M.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.