Volumn 41, Issue 2, 2009, Pages 57-63

A human factors analysis of cardiopulmonary bypass machines

Author keywords

Cardiopulmonary bypass; Equipment; Patient safety; Perfusion

Indexed keywords

ALARM MONITORING; ANESTHESIST; ANTICOAGULATION; ARTICLE; BIOCOMPATIBILITY; CARBON DIOXIDE TENSION; CARDIOPULMONARY BYPASS; CLINICAL PRACTICE; ERGONOMICS; HEART LUNG MACHINE; HEART PERFUSION; HUMAN; INTERPERSONAL COMMUNICATION; MEAN ARTERIAL PRESSURE; NURSE; OPERATING ROOM; OPERATING ROOM PERSONNEL; OXYGEN SATURATION; OXYGEN TENSION; PATIENT CARE; PATIENT SAFETY; SURGEON; ADULT; CHILD; EQUIPMENT; EQUIPMENT DESIGN; INSTRUMENTATION; OBSERVATION;

EID: 70349567211     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (18)

References (19)
  • 1
    • 0000670086 scopus 로고
    • Artificial maintenance of circulation during experimental occlusion of the pulmonary artery
    • Gibbon JH Jr. Artificial maintenance of circulation during experimental occlusion of the pulmonary artery. Arch Surg. 1937;34: 1105-31.
    • (1937) Arch Surg , vol.34 , pp. 1105-1131
    • Gibbon Jr., J.H.1
  • 2
    • 78651036121 scopus 로고
    • Application of a mechanical heart and lung apparatus to cardiac surgery
    • Gibbon JH Jr. Application of a mechanical heart and lung apparatus to cardiac surgery. Minn Med. 1954;37:171-85.
    • (1954) Minn Med , vol.37 , pp. 171-185
    • Gibbon Jr., J.H.1
  • 3
    • 78651043056 scopus 로고
    • Intracardiac surgery with the aid of a mechanical pump-oxygenator system (Gibbon type): Report of eight cases
    • Kirklin JW, DuShane JW, Patrick RT, et al. Intracardiac surgery with the aid of a mechanical pump-oxygenator system (Gibbon type): Report of eight cases. Proc Staff Meet Mayo Clin. 1955;30: 201-6.
    • (1955) Proc Staff Meet Mayo Clin , vol.30 , pp. 201-206
    • Kirklin, J.W.1    DuShane, J.W.2    Patrick, R.T.3
  • 4
    • 78651040356 scopus 로고
    • An improved mechanical heart and lung apparatus: Its use during open cardiotomy in experimental animals
    • Miller BJ, Gibbon JH, Fineburg C. An improved mechanical heart and lung apparatus: Its use during open cardiotomy in experimental animals. Med Clin North Am. 1953;1:1603-24.
    • (1953) Med Clin North Am , vol.1 , pp. 1603-1624
    • Miller, B.J.1    Gibbon, J.H.2    Fineburg, C.3
  • 6
    • 77049261245 scopus 로고
    • A simple, expendable, artificial oxygenator for open heart surgery
    • DeWall RA, Gott VL, Lillehei CW, et al. A simple, expendable, artificial oxygenator for open heart surgery. Surg Clin North Am. 1956;36:1025-34.
    • (1956) Surg Clin North Am , vol.36 , pp. 1025-1034
    • DeWall, R.A.1    Gott, V.L.2    Lillehei, C.W.3
  • 7
    • 0014550960 scopus 로고
    • Production of a silicone rubber film for the membrane lung
    • Burns N. Production of a silicone rubber film for the membrane lung. Biomed Eng. 1969;4:356-9.
    • (1969) Biomed Eng , vol.4 , pp. 356-359
    • Burns, N.1
  • 8
    • 33646592099 scopus 로고    scopus 로고
    • Eleven keys to designing error-resistant medical devices
    • Wiklund ME. Eleven keys to designing error-resistant medical devices. Medical Device and Diagnostic Industry . 2002:86-88.
    • (2002) Medical Device and Diagnostic Industry , pp. 86-88
    • Wiklund, M.E.1
  • 10
    • 23844461095 scopus 로고    scopus 로고
    • Perfusion safety: Defining the problem
    • Palanzo D. Perfusion safety: Defining the problem. Perfusion. 2005;20:195-203.
    • (2005) Perfusion , vol.20 , pp. 195-203
    • Palanzo, D.1
  • 11
  • 12
    • 0034982843 scopus 로고    scopus 로고
    • An update on perfusion safety: Does the type of perfusion practice affect the rate of incidents related to cardiopulmonary bypass?
    • Stammers AH, Mejak BL. An update on perfusion safety: Does the type of perfusion practice affect the rate of incidents related to cardiopulmonary bypass? Perfusion. 2001;16:189-98.
    • (2001) Perfusion , vol.16 , pp. 189-198
    • Stammers, A.H.1    Mejak, B.L.2
  • 13
    • 0001775576 scopus 로고
    • Heuristic evaluation
    • Nielsen J, Mack RL, eds, New York: John Wiley & Sons;
    • Nielsen J. Heuristic evaluation. In: Nielsen J, Mack RL, eds. Usability Inspection Methods . New York: John Wiley & Sons; 1994:25-61.
    • (1994) Usability Inspection Methods , pp. 25-61
    • Nielsen, J.1
  • 16
    • 0343251564 scopus 로고    scopus 로고
    • Attention in perception and display space
    • Wickens C, Hollands J, eds, 3rd ed. Upper Saddle River, NJ: Prentice-Hall;
    • Wickens C, Hollands J. Attention in perception and display space. In: Wickens C, Hollands J, eds. Engineering Psychology and Human Performance. 3rd ed. Upper Saddle River, NJ: Prentice-Hall; 2000: 97-100.
    • (2000) Engineering Psychology and Human Performance , pp. 97-100
    • Wickens, C.1    Hollands, J.2
  • 18
    • 20644444803 scopus 로고    scopus 로고
    • Fewer but better auditory alarms will improve patient safety
    • Edworthg J, Hellier E. Fewer but better auditory alarms will improve patient safety. Qual Saf Health Care. 2005;14:212-5.
    • (2005) Qual Saf Health Care , vol.14 , pp. 212-215
    • Edworthg, J.1    Hellier, E.2
  • 19
    • 85160890243 scopus 로고    scopus 로고
    • Organizations National Patient Safety Goals , The Joint Commission. Oakbrook Terrace, IL, 2003.
    • Organizations National Patient Safety Goals , The Joint Commission. Oakbrook Terrace, IL, 2003.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.