메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1180-1187

Direct torque control of three-phase PM brushless AC motor with one phase open-circuit fault

Author keywords

Brushless drive; Direct torque control; Fault tolerant control; Permanent magnet machine

Indexed keywords

BACK-EMF; BRUSHLESS AC MOTORS; BRUSHLESS DRIVE; CURRENT PATHS; DIRECT TORQUE CONTROL; FAULT OPERATION; FAULT-TOLERANT CONTROL; FAULTY SYSTEMS; FLUX CONTROL; FLUX ESTIMATION; MEASURED RESULTS; OPEN-CIRCUIT FAULT; PERMANENT MAGNET MACHINE; PROTOTYPE SYSTEM; SAMPLING TIME; SIMULATION RESULT; THREE PHASE;

EID: 70349464983     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMDC.2009.5075353     Document Type: Conference Paper
Times cited : (30)

References (18)
  • 1
    • 0036446252 scopus 로고    scopus 로고
    • Fault tolerant motor drive system with redundancy for critical applications
    • N. Ertugruk, W. Soong, F. Dostal, and D. Saxon, "Fault tolerant motor drive system with redundancy for critical applications," in Conf. Rec.IEEE PESC, 2002, vol. 3, pp. 1457-1462I.
    • (2002) Conf. Rec.IEEE PESC , vol.3
    • Ertugruk, N.1    Soong, W.2    Dostal, F.3    Saxon, D.4
  • 2
    • 8744310553 scopus 로고    scopus 로고
    • Short-circuit fault mitigation methods for interior PM synchronous machine drives using six-leg inverters
    • B. A. Welchko, T. M. Jahns, and T. A. Lipo, "Short-circuit fault mitigation methods for interior PM synchronous machine drives using six-leg inverters," in Conf. Rec.IEEE PESC, 2004, pp. 2133-2139.
    • (2004) Conf. Rec.IEEE PESC , pp. 2133-2139
    • Welchko, B.A.1    Jahns, T.M.2    Lipo, T.A.3
  • 3
    • 0021386280 scopus 로고
    • A comparative study investigation of induction machine drives with a component minimized voltage fed inverter under different control options
    • Mar./April
    • H. W. V. Broeck, and J. V. D. Wyk, "A comparative study investigation of induction machine drives with a component minimized voltage fed inverter under different control options," IEEE Trans. Industry Applicat., vol.20, no.2, pp.309-320, Mar./April 1984.
    • (1984) IEEE Trans. Industry Applicat , vol.20 , Issue.2 , pp. 309-320
    • Broeck, H.W.V.1    Wyk, J.V.D.2
  • 4
    • 0028480661 scopus 로고
    • Fault mode single-phase operation of a variable frequency induction motor drive and improvement of pulsating torque characteristics
    • Aug
    • D. Kastha, and B. K. Bose, "Fault mode single-phase operation of a variable frequency induction motor drive and improvement of pulsating torque characteristics," IEEE Trans. Ind. Electron., vol. 41, no. 4, pp. 426-433, Aug. 1994.
    • (1994) IEEE Trans. Ind. Electron , vol.41 , Issue.4 , pp. 426-433
    • Kastha, D.1    Bose, B.K.2
  • 5
    • 3843127550 scopus 로고    scopus 로고
    • Fault tolerant three-phase AC motor drive topologies: A comparison of features, cost, and limitations
    • July
    • B. A. Welchko, T.A. Lipo, T. M. Jahn, and S. E. Schulz, "Fault tolerant three-phase AC motor drive topologies: A comparison of features, cost, and limitations," IEEE Trans. Power Electron., vol.19, no.4, pp.1108-1116, July 2004.
    • (2004) IEEE Trans. Power Electron , vol.19 , Issue.4 , pp. 1108-1116
    • Welchko, B.A.1    Lipo, T.A.2    Jahn, T.M.3    Schulz, S.E.4
  • 6
    • 0027803146 scopus 로고
    • Disturbance free operation of a multiphase current regulated motor drive with an opened phase
    • Toronto, Ont, Canada
    • J. R. Fu, and T. A. Lipo, "Disturbance free operation of a multiphase current regulated motor drive with an opened phase," IAS Annu. Meeting, vol. 1, pp. 637-644, 1993, Toronto, Ont., Canada.
    • (1993) IAS Annu. Meeting , vol.1 , pp. 637-644
    • Fu, J.R.1    Lipo, T.A.2
  • 7
    • 0027660696 scopus 로고
    • A strategy for improving reliability of field-oriented controlled induction motor drives
    • Sept./Oct
    • T. H. Liu, J. R. Fu, and T. A. Lipo, "A strategy for improving reliability of field-oriented controlled induction motor drives, " IEEE Trans. Industry Applicat., vol. 29, no.5, pp.910-918, Sept./Oct 1993.
    • (1993) IEEE Trans. Industry Applicat , vol.29 , Issue.5 , pp. 910-918
    • Liu, T.H.1    Fu, J.R.2    Lipo, T.A.3
  • 8
    • 0035330628 scopus 로고    scopus 로고
    • An induction motor drive system with improved fault tolerant
    • May./June
    • M. B. R. Correa, C. B. Jacobina, E. R. C. Silva, and A. M. N. Lima, "An induction motor drive system with improved fault tolerant," IEEE Trans. Industry Applicat., vol. 37, no.3, pp.873-979, May./June 2001.
    • (2001) IEEE Trans. Industry Applicat , vol.37 , Issue.3 , pp. 873-979
    • Correa, M.B.R.1    Jacobina, C.B.2    Silva, E.R.C.3    Lima, A.M.N.4
  • 9
    • 0035058098 scopus 로고    scopus 로고
    • R. L. A. Ribeiro, C. B. Jacobina, A. M. N. Lima, and E. R. C. Silva, A strategy for improving reliability of motor drive systems using a four-leg three-phase converter, Applied Power Electronics Conference and Exposition, APEC 2001, 1, pp. 385-391, Anaheim, CA, USA.
    • R. L. A. Ribeiro, C. B. Jacobina, A. M. N. Lima, and E. R. C. Silva, "A strategy for improving reliability of motor drive systems using a four-leg three-phase converter," Applied Power Electronics Conference and Exposition, APEC 2001, vol. 1, pp. 385-391, Anaheim, CA, USA.
  • 10
    • 0141953037 scopus 로고    scopus 로고
    • Optimum torque control of faulttolerant permanent magnet blushless machines
    • Sep
    • J. Wang, K. Atallah, and D. Howe, "Optimum torque control of faulttolerant permanent magnet blushless machines," IEEE Trans. Magnetics, vol. 39, no.9, pp.2962-2964, Sep. 2003.
    • (2003) IEEE Trans. Magnetics , vol.39 , Issue.9 , pp. 2962-2964
    • Wang, J.1    Atallah, K.2    Howe, D.3
  • 11
    • 0026220761 scopus 로고
    • A permanent magnet motro drive without a shaft sensors
    • Sep./Oct
    • R. Wu and G. R. Slemon, "A permanent magnet motro drive without a shaft sensors," IEEE Trans. Industry Applicat., vol. 27, no.5, pp.1005-1011, Sep./Oct. 1991.
    • (1991) IEEE Trans. Industry Applicat , vol.27 , Issue.5 , pp. 1005-1011
    • Wu, R.1    Slemon, G.R.2
  • 12
    • 0034295780 scopus 로고    scopus 로고
    • Experimental fault-tolerant control of a PMSM drive
    • October
    • S. Bolognani, M. Zordan, and M. Zigliotto, "Experimental fault-tolerant control of a PMSM drive," IEEE Trans. Power Electron., vol.47, no.5, pp.1134-1141, October 2000.
    • (2000) IEEE Trans. Power Electron , vol.47 , Issue.5 , pp. 1134-1141
    • Bolognani, S.1    Zordan, M.2    Zigliotto, M.3
  • 13
    • 0037704405 scopus 로고    scopus 로고
    • Innovative remedial strategies for inverter faults in IPM synchronous motor drives
    • June
    • N. Bianchi, S. Bolognani, M. Zigliotto, and M. Zordan, "Innovative remedial strategies for inverter faults in IPM synchronous motor drives," IEEE Trans. Energy Con., Vol.18, no.2, pp. 306-314, June 2003.
    • (2003) IEEE Trans. Energy Con , vol.18 , Issue.2 , pp. 306-314
    • Bianchi, N.1    Bolognani, S.2    Zigliotto, M.3    Zordan, M.4
  • 14
    • 33846996004 scopus 로고    scopus 로고
    • A modified direct torque control for PMSM under inverter fault
    • D. Sun, Y. He, "A modified direct torque control for PMSM under inverter fault," in ICEM 2005, vol. 3, pp. 2468-2473.
    • ICEM 2005 , vol.3 , pp. 2468-2473
    • Sun, D.1    He, Y.2
  • 15
    • 0022778662 scopus 로고
    • A new quick-response and highefficiency control strategy of an induction motor
    • Sept./Oct
    • I. Takahashi, and T. Noguchi, "A new quick-response and highefficiency control strategy of an induction motor," IEEE Trans. Ind. Applicat, vol. 22, no.5, pp. 820-827, Sept./Oct. 1986.
    • (1986) IEEE Trans. Ind. Applicat , vol.22 , Issue.5 , pp. 820-827
    • Takahashi, I.1    Noguchi, T.2
  • 16
    • 0030673794 scopus 로고    scopus 로고
    • New integration algorithm for estimating motor flux over a wide speed range
    • J. Hu, and B. Wu, "New integration algorithm for estimating motor flux over a wide speed range," ," in Conf. Rec.IEEE PESC, 1997, vol. 2, pp. 1075-1081.
    • (1997) Conf. Rec.IEEE PESC , vol.2 , pp. 1075-1081
    • Hu, J.1    Wu, B.2
  • 17
    • 0036630787 scopus 로고    scopus 로고
    • Improve speed estimation in sensorless PM brushless AC
    • Jul./Aug
    • J. X. Shen, Z. Q. Zhu, and D. Howe "Improve speed estimation in sensorless PM brushless AC," IEEE Trans. Industry Applicat., vol. 38,no.4, pp.1072-1080, Jul./Aug. 2002.
    • (2002) IEEE Trans. Industry Applicat , vol.38 , Issue.4 , pp. 1072-1080
    • Shen, J.X.1    Zhu, Z.Q.2    Howe, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.