메뉴 건너뛰기




Volumn , Issue , 2008, Pages 1-227

Principles of Fire Risk Assessment in Buildings

Author keywords

[No Author keywords available]

Indexed keywords


EID: 70349457600     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9780470714065     Document Type: Book
Times cited : (45)

References (124)
  • 1
    • 84889268718 scopus 로고    scopus 로고
    • Guide for the Evaluation of Fire Risk Assessments
    • NFPA 551, National Fire Protection Association, Quincy, MA
    • NFPA 551 (2007) Guide for the Evaluation of Fire Risk Assessments, National Fire Protection Association, Quincy, MA.
    • (2007)
  • 2
    • 79952153092 scopus 로고    scopus 로고
    • Engineering Guide to Fire Risk Assessment
    • SFPE, Society of Fire Protection Engineers, Bethesda, MD
    • SFPE (2006) Engineering Guide to Fire Risk Assessment, Society of Fire Protection Engineers, Bethesda, MD.
    • (2006)
  • 3
    • 0342555652 scopus 로고    scopus 로고
    • Introduction to Performance-Based Fire Safety
    • Society of Fire Protection Engineers and National Fire Protection Association, Quincy, MA
    • Custer, R.L.P. and Meacham, B.J. (1997) Introduction to Performance-Based Fire Safety, Society of Fire Protection Engineers and National Fire Protection Association, Quincy, MA, pp. 130-34.
    • (1997) , pp. 130-134
    • Custer, R.L.P.1    Meacham, B.J.2
  • 4
    • 84889306790 scopus 로고    scopus 로고
    • Concepts of Fire Risk Assessment
    • Report No. NRCC-46393, National Research Council Canada, Ottawa, ON
    • Yung, D. and Benichou, N. (2003) Concepts of Fire Risk Assessment, Report No. NRCC-46393, National Research Council Canada, Ottawa, ON, pp. 1-4.
    • (2003) , pp. 1-4
    • Yung, D.1    Benichou, N.2
  • 5
    • 42349111064 scopus 로고    scopus 로고
    • Fatal Fire Scenarios in Canadian Houses
    • Internal Report No. 830, National Research Council Canada, Ottawa, ON
    • Yung, D. and Lougheed, G.D. (2001) Fatal Fire Scenarios in Canadian Houses, Internal Report No. 830, National Research Council Canada, Ottawa, ON, pp. 1-6.
    • (2001) , pp. 1-6
    • Yung, D.1    Lougheed, G.D.2
  • 6
    • 48749117657 scopus 로고    scopus 로고
    • Searching for answers to the Cocoanut Grove
    • NFPA Journal, May/June
    • Beller, D. and Sapochetti, J. (2000) Searching for answers to the Cocoanut Grove. NFPA Journal, May/June, 84-92.
    • (2000) , pp. 84-92
    • Beller, D.1    Sapochetti, J.2
  • 7
    • 4243925421 scopus 로고    scopus 로고
    • At Least 96 Killed in Night Club Inferno
    • CNN News, 21 Feb 2003
    • CNN News (2003) At Least 96 Killed in Night Club Inferno, 21 Feb 2003, www.cnn.com/2003/US/Northeast/02/21/deadly.nightclub.fire/
    • (2003)
  • 8
    • 0009249062 scopus 로고    scopus 로고
    • Fire Losses in Canada
    • Council of Canadian Fire Marshals and Fire Commissioners, Annual Report, Table 3b
    • Council of Canadian Fire Marshals and Fire Commissioners (1996) Fire Losses in Canada, Annual Report, Table 3b, http://www.ccfmfc.ca/stats/en/reporte96.pdf
    • (1996)
  • 9
    • 77952424040 scopus 로고    scopus 로고
    • Fire Losses in Canada
    • Council of Canadian Fire Marshals and Fire Commissioners, Annual Report, Table 1
    • Council of Canadian Fire Marshals and Fire Commissioners (2001) Fire Losses in Canada, Annual Report, Table 1, http://www.ccfmfc.ca/stats/en/reporte01.pdf
    • (2001)
  • 10
    • 84889290335 scopus 로고    scopus 로고
    • World Fire Statistics Bulletin
    • The Geneva Association, No. 21, Table 4, October 2005
    • The Geneva Association (2005) World Fire Statistics Bulletin, No. 21, Table 4, October 2005, www.genevaassociation.org
    • (2005)
  • 11
    • 84889451026 scopus 로고    scopus 로고
    • Fire in the U.S. and Canada
    • NFPA Report, Quincy, MA, April 2003
    • Hall, J.R., Jr. (2003) Fire in the U.S. and Canada, NFPA Report, Quincy, MA, April 2003, p. 3.
    • (2003) , pp. 3
    • Hall Jr., J.R.1
  • 12
    • 0024656555 scopus 로고
    • The national estimates approach to U.S. Fire statistics
    • Hall, J.R., Jr. and Harwood, B. (1989) The national estimates approach to U.S. Fire statistics. Fire Technology, 25 (2), 99-113.
    • (1989) Fire Technology , vol.25 , Issue.2 , pp. 99-113
    • Hall Jr., J.R.1    Harwood, B.2
  • 13
    • 79951943461 scopus 로고    scopus 로고
    • The NIST Station night club fire investigation: physical simulation of the fire
    • Summer 31
    • Madrzykowski, D., Bryner, N. and Kerber, S.I. (2006), The NIST Station night club fire investigation: physical simulation of the fire. Fire Protection Engineering Magazine, Summer 31, 35-46, http://www.fpemag.com/archives/article.asp?issue id=37&i=245
    • (2006) Fire Protection Engineering Magazine , pp. 35-46
    • Madrzykowski, D.1    Bryner, N.2    Kerber, S.I.3
  • 14
    • 84889487114 scopus 로고    scopus 로고
    • Census Canadian Private Households by Size
    • Statistics Canada
    • Statistics Canada (1996) Census Canadian Private Households by Size, http://www.statcan.ca/english/census96/oct14/hou.pdf
    • (1996)
  • 15
    • 42349111064 scopus 로고    scopus 로고
    • Fatal Fire Scenarios in Canadian Houses
    • IRC Internal Report No. 830, National Research Council Canada, Ottawa, ON, October 2001, Figure 1
    • Yung, D. and Lougheed, G.D. (2001) Fatal Fire Scenarios in Canadian Houses, IRC Internal Report No. 830, National Research Council Canada, Ottawa, ON, October 2001, Figure 1.
    • (2001)
    • Yung, D.1    Lougheed, G.D.2
  • 16
    • 84889268718 scopus 로고    scopus 로고
    • Guide for the Evaluation of Fire Risk Assessments
    • NFPA 551, National Fire Protection Association, Quincy, MA
    • NFPA 551 (2007) Guide for the Evaluation of Fire Risk Assessments, National Fire Protection Association, Quincy, MA.
    • (2007)
  • 17
    • 0003710227 scopus 로고    scopus 로고
    • Engineering Guide to Performance-Based Fire Protection Analysis and Design of Buildings
    • SFPE, National Fire Protection Association, Quincy, MA
    • SFPE (2000) Engineering Guide to Performance-Based Fire Protection Analysis and Design of Buildings, National Fire Protection Association, Quincy, MA.
    • (2000)
  • 18
    • 84889434114 scopus 로고    scopus 로고
    • Standards Australia and Standards New Zealand AS/NZS4360 Risk Management
    • Standards Association of Australia, Strathfield, NSW
    • Standards Association of Australia (1999) Standards Australia and Standards New Zealand AS/NZS4360 Risk Management, Strathfield, NSW.
    • (1999)
  • 19
    • 0009249062 scopus 로고    scopus 로고
    • Fire Losses in Canada
    • Council of Canadian Fire Marshals and Fire Commissioners, Annual Report, Table 3b
    • Council of Canadian Fire Marshals and Fire Commissioners (1996) Fire Losses in Canada, Annual Report, Table 3b, http://www.ccfmfc.ca/stats/en/reporte96.pdf
    • (1996)
  • 20
    • 0009024179 scopus 로고    scopus 로고
    • The Smoking-Material Fire Problem
    • NFPA Report, August 2006, Table 6: Smoking-Material Fires in Homes, by Area of Fire Origin, NFPA, Quincy, MA
    • Hall, J.R., Jr. (2006) The Smoking-Material Fire Problem, NFPA Report, August 2006, Table 6: Smoking-Material Fires in Homes, by Area of Fire Origin, NFPA, Quincy, MA.
    • (2006)
    • Hall Jr., J.R.1
  • 21
    • 84889446130 scopus 로고    scopus 로고
    • U.S. Experience with Sprinklers and other Fire Extinguishing Equipment
    • NFPA Report, August 2005, Table 9: Reduction in Civilian Deaths, NFPA, Quincy, MA
    • Kimberly, D.R. and Hall, J.R., Jr. (2005a) U.S. Experience with Sprinklers and other Fire Extinguishing Equipment, NFPA Report, August 2005, Table 9: Reduction in Civilian Deaths, NFPA, Quincy, MA.
    • (2005)
    • Kimberly, D.R.1    Hall Jr., J.R.2
  • 22
    • 84889446130 scopus 로고    scopus 로고
    • U.S. Experience with Sprinklers and other Fire Extinguishing Equipment
    • NFPA Report, August 2005, Table 7B: Sprinklers Performance, NFPA, Quincy, MA
    • Kimberly, D.R. and Hall, J.R., Jr. (2005b) U.S. Experience with Sprinklers and other Fire Extinguishing Equipment, NFPA Report, August 2005, Table 7B: Sprinklers Performance, NFPA, Quincy, MA.
    • (2005)
    • Kimberly, D.R.1    Hall Jr., J.R.2
  • 23
    • 13444271361 scopus 로고    scopus 로고
    • Guide on Alternative Approaches to Life Safety
    • NFPA 101A, NFPA, Quincy, MA
    • NFPA 101A (2004) Guide on Alternative Approaches to Life Safety, NFPA, Quincy, MA.
    • (2004)
  • 24
    • 84889494325 scopus 로고    scopus 로고
    • Leading Causes of Structured Fires in Homes, 1999-2002 Annual Averages
    • NFPA Fire Statistics, NFPA, Quincy, MA
    • NFPA Fire Statistics (2006) Leading Causes of Structured Fires in Homes, 1999-2002 Annual Averages, NFPA, Quincy, MA.
    • (2006)
  • 25
    • 84889487114 scopus 로고    scopus 로고
    • Census Canadian Private Households by Size
    • Statistics Canada
    • Statistics Canada (1996) Census Canadian Private Households by Size, http://www.statcan.ca/english/census96/oct14/hou.pdf
    • (1996)
  • 26
    • 77956926476 scopus 로고    scopus 로고
    • Fire risk indexing, SFPE Handbook of Fire Protection Engineering
    • 3rd edn, Section 5-10, NFPA, Quincy, MA
    • Watts, J.M., Jr. (2002) Fire risk indexing, SFPE Handbook of Fire Protection Engineering, 3rd edn, Section 5-10, NFPA, Quincy, MA.
    • (2002)
    • Watts Jr., J.M.1
  • 27
    • 41549092413 scopus 로고    scopus 로고
    • Heat release rates, SFPE Handbook of Fire Protection Engineering
    • 3rd edn, Section 3, Chapter 1, National Fire Protection Association, Quincy, MA
    • Babrauskas, V. (2002) Heat release rates, SFPE Handbook of Fire Protection Engineering, 3rd edn, Section 3, Chapter 1, National Fire Protection Association, Quincy, MA.
    • (2002)
    • Babrauskas, V.1
  • 28
    • 84889364904 scopus 로고    scopus 로고
    • Initiation and development of fire within the enclosure of origin (Sub-system 1), Application of Fire Safety Engineering Principles to the Design of Buildings
    • BSI, PD7974-1, Part 1, British Standards Institution, London
    • BSI (2003) Initiation and development of fire within the enclosure of origin (Sub-system 1), Application of Fire Safety Engineering Principles to the Design of Buildings, PD7974-1, Part 1, British Standards Institution, London.
    • (2003)
  • 29
    • 84889358637 scopus 로고    scopus 로고
    • Probabilistic risk assessment, Application of Fire Safety Engineering Principles to the Design of Buildings
    • BSI, PD7974-7, Part 7, British Standards Institution, London
    • BSI (2003) Probabilistic risk assessment, Application of Fire Safety Engineering Principles to the Design of Buildings, PD7974-7, Part 7, British Standards Institution, London.
    • (2003)
  • 30
    • 84873572982 scopus 로고    scopus 로고
    • Development of A Fuel Package for use in the Fire Performance of Houses Project
    • Research Report IRC-RR-207, Institute for Research in Construction, National Research Council Canada, Ottawa, March 2006
    • Bwalya, A.C., Carpenter, D.W., Kanabus-Kaminska, M. et al. (2006) Development of A Fuel Package for use in the Fire Performance of Houses Project, Research Report IRC-RR-207, Institute for Research in Construction, National Research Council Canada, Ottawa, March 2006.
    • (2006)
    • Bwalya, A.C.1    Carpenter, D.W.2    Kanabus-Kaminska, M.3
  • 31
    • 1842446250 scopus 로고    scopus 로고
    • The Combustion Behaviour of Upholstered Furniture Materials in New Zealand
    • Fire Engineering Research Report 2000/4, University of Canterbury, Christchurch
    • Denize, H. (2000) The Combustion Behaviour of Upholstered Furniture Materials in New Zealand, Fire Engineering Research Report 2000/4, University of Canterbury, Christchurch.
    • (2000)
    • Denize, H.1
  • 32
    • 84949776498 scopus 로고    scopus 로고
    • An Introduction to Fire Dynamics
    • 2nd edn, John Wiley & Sons, Ltd, Chichester
    • Drysdale, D. (1998) An Introduction to Fire Dynamics, 2nd edn, John Wiley & Sons, Ltd, Chichester.
    • (1998)
    • Drysdale, D.1
  • 33
    • 84889453248 scopus 로고
    • Fire probabilities-smouldering, flaming or full development?
    • Fire Safety and Engineering Technical Papers, Book 1, Part 3, Chapter 7, The Warren Centre, University of Sydney, December 1989, Australia
    • Eaton, C. (1989) Fire probabilities-smouldering, flaming or full development? Fire Safety and Engineering Technical Papers, Book 1, Part 3, Chapter 7, The Warren Centre, University of Sydney, December 1989, Australia.
    • (1989)
    • Eaton, C.1
  • 34
    • 84555189748 scopus 로고    scopus 로고
    • CBUF Model I, Applied to Exemplary New Zealand Furniture
    • Proceedings of the Sixth International Symposium on Fire Safety Science, July 1999, University of Poitiers, France
    • Enright, P.A. and Fleischmann, C.M. (1999) CBUF Model I, Applied to Exemplary New Zealand Furniture. Proceedings of the Sixth International Symposium on Fire Safety Science, July 1999, University of Poitiers, France, pp. 147-57.
    • (1999) , pp. 147-157
    • Enright, P.A.1    Fleischmann, C.M.2
  • 35
    • 84889444712 scopus 로고    scopus 로고
    • Canadian and U.S.A. Fire Statistics for use in the Risk-Cost Assessment Model, Internal Report No. 637, Institute for Research in Construction
    • National Research Council Canada, January 1993, Ottawa
    • Gaskin, J. and Yung, D. (1997) Canadian and U.S.A. Fire Statistics for use in the Risk-Cost Assessment Model, Internal Report No. 637, Institute for Research in Construction, National Research Council Canada, January 1993, Ottawa.
    • (1997)
    • Gaskin, J.1    Yung, D.2
  • 36
    • 84889435422 scopus 로고    scopus 로고
    • Full-Scale Compartment Fire Experiments onUpholstered Furniture, Fire Engineering Research Report 2000/5
    • University of Canterbury, Christchurch
    • Girgis,N. (2000) Full-Scale Compartment Fire Experiments onUpholstered Furniture, Fire Engineering Research Report 2000/5, University of Canterbury, Christchurch.
    • (2000)
    • Girgis, N.1
  • 37
    • 84889378781 scopus 로고    scopus 로고
    • Development of Design Fires for Commercial Buildings
    • Proceedings of the International Conference on Fire Safety Engineering, March 2004, Sydney
    • Hadjisophocleous, G. and Zalok, E. (2004) Development of Design Fires for Commercial Buildings. Proceedings of the International Conference on Fire Safety Engineering, March 2004, Sydney.
    • (2004)
    • Hadjisophocleous, G.1    Zalok, E.2
  • 38
    • 0043146999 scopus 로고
    • International Standards-Fire Tests-Full Scale Room Test for Surface Products
    • ISO, ISO9705:1993(E), International Organization for Standardization, Geneva
    • ISO (1993) International Standards-Fire Tests-Full Scale Room Test for Surface Products, ISO9705:1993(E), International Organization for Standardization, Geneva.
    • (1993)
  • 39
    • 0013322573 scopus 로고    scopus 로고
    • Fire Safety Engineering, Part 2-Design fire Scenarios and Design fires
    • ISO, ISO/TC92/SC4/WG6/N49 draft document, International Organization for Standardization, Kyoto meeting, Japan, April 2003
    • ISO (2003) Fire Safety Engineering, Part 2-Design fire Scenarios and Design fires, ISO/TC92/SC4/WG6/N49 draft document, International Organization for Standardization, Kyoto meeting, Japan, April 2003.
    • (2003)
  • 40
    • 0003708137 scopus 로고    scopus 로고
    • Enclosure Fire Dynamics
    • CRC Press LLC, Boca Raton, FL
    • Karlsson, B. and Quintiere, J.G. (2000) Enclosure Fire Dynamics, CRC Press LLC, Boca Raton, FL.
    • (2000)
    • Karlsson, B.1    Quintiere, J.G.2
  • 41
    • 84889446130 scopus 로고    scopus 로고
    • U.S. Experience with Sprinklers and other Fire Extinguishing Equipment
    • NFPA Report, August 2005, Table 7B: Sprinklers Performance, National Fire Protection Association, Quincy, MA
    • Kimberly, D.R. and Hall, J.R., Jr. (2005) U.S. Experience with Sprinklers and other Fire Extinguishing Equipment, NFPA Report, August 2005, Table 7B: Sprinklers Performance, National Fire Protection Association, Quincy, MA.
    • (2005)
    • Kimberly, D.R.1    Hall Jr., J.R.2
  • 42
    • 0037773268 scopus 로고    scopus 로고
    • Fire Dynamics Simulator (Version 4): user's Guide, NIST Special Publication 1019
    • National Institute of Standards & Technology, March 2006, Gaithersburg, MD
    • McGrattan, K.B. and Forney, G. (2006) Fire Dynamics Simulator (Version 4): user's Guide, NIST Special Publication 1019, National Institute of Standards & Technology, March 2006, Gaithersburg, MD.
    • (2006)
    • McGrattan, K.B.1    Forney, G.2
  • 43
    • 34547238708 scopus 로고    scopus 로고
    • CFAST: Consolidated Model of Fire Growth and Smoke Transport (Version 6): user's Guide
    • NIST Special Publication 1041, National Institute of Standards and Technology, August 2005, Gaithersburg, MD
    • Peacock, R.D., Jones, W.W., Reneke, P.A. and Forney, G.P. (2005) CFAST: Consolidated Model of Fire Growth and Smoke Transport (Version 6): user's Guide, NIST Special Publication 1041, National Institute of Standards and Technology, August 2005, Gaithersburg, MD.
    • (2005)
    • Peacock, R.D.1    Jones, W.W.2    Reneke, P.A.3    Forney, G.P.4
  • 44
    • 0020177370 scopus 로고
    • An analysis of smouldering fires in closed compartments and their hazard due to carbon monoxide
    • Quintiere, J.G., Birky, M., Macdonald, F. and Smith, G. (1982) An analysis of smouldering fires in closed compartments and their hazard due to carbon monoxide. Fire and Materials, 6(3-4), 99-110.
    • (1982) Fire and Materials , vol.6 , Issue.3-4 , pp. 99-110
    • Quintiere, J.G.1    Birky, M.2    Macdonald, F.3    Smith, G.4
  • 45
    • 0001542826 scopus 로고    scopus 로고
    • Hazard calculations, SFPE Handbook of Fire Protection Engineering
    • SFPE, 3rd edn, Section 3, National Fire Protection Association, Quincy, MA
    • SFPE (2002) Hazard calculations, SFPE Handbook of Fire Protection Engineering, 3rd edn, Section 3, National Fire Protection Association, Quincy, MA.
    • (2002)
  • 46
    • 0043022857 scopus 로고    scopus 로고
    • Generation of heat and chemical compounds in fires, SFPE Handbook of Fire Protection Engineering
    • 3rd edn, Section 3: Chapter 4, National Fire Protection Association, Quincy, MA
    • Tewarson, A. (2002) Generation of heat and chemical compounds in fires, SFPE Handbook of Fire Protection Engineering, 3rd edn, Section 3: Chapter 4, National Fire Protection Association, Quincy, MA.
    • (2002)
    • Tewarson, A.1
  • 47
    • 0242638706 scopus 로고    scopus 로고
    • BRANZFIRE Technical Reference Guide, BRANZ Study Report 92
    • Building Research Association of New Zealand, New Zealand
    • Wade, C.A. (2002) BRANZFIRE Technical Reference Guide, BRANZ Study Report 92, Building Research Association of New Zealand, New Zealand.
    • (2002)
    • Wade, C.A.1
  • 48
    • 0013455917 scopus 로고    scopus 로고
    • Design Fires for Fire Risk Assessment and Fire Safety Designs
    • Proceedings of the 4th Fire Risk and Hazard Research Application Symposium, June 23-25, 1999 San Diego, CA
    • Yung, D. and Benichou, N. (1999) Design Fires for Fire Risk Assessment and Fire Safety Designs. Proceedings of the 4th Fire Risk and Hazard Research Application Symposium, June 23-25, 1999 San Diego, CA, pp. 101-12.
    • (1999) , pp. 101-112
    • Yung, D.1    Benichou, N.2
  • 49
    • 0036667171 scopus 로고    scopus 로고
    • How design fires can be used in fire hazard analysis
    • Yung, D. and Benichou, N. (2002) How design fires can be used in fire hazard analysis. Fire Technology, 38(3), 231-42.
    • (2002) Fire Technology , vol.38 , Issue.3 , pp. 231-242
    • Yung, D.1    Benichou, N.2
  • 50
    • 84889288446 scopus 로고    scopus 로고
    • Development of Design Fires for Buildings
    • Proceedings of the International Conference on Fire Safety Engineering, March 2004, Sydney
    • Yung, D., Wade, C. and Fleischmann, C. (2004) Development of Design Fires for Buildings. Proceedings of the International Conference on Fire Safety Engineering, March 2004, Sydney.
    • (2004)
    • Yung, D.1    Wade, C.2    Fleischmann, C.3
  • 51
    • 84889474897 scopus 로고    scopus 로고
    • Improving the Technical Basis for Testing and Design of Fire-Resistant Structures, Emerging Trends eNewsletter
    • Almand, K. (2006) Improving the Technical Basis for Testing and Design of Fire-Resistant Structures, Emerging Trends eNewsletter, Society of Fire Protection Engineers, Issue 3, http://www.fpemag.com/archives/enewsletter.asp?i=5
    • (2006) Society of Fire Protection Engineers , Issue.3
    • Almand, K.1
  • 52
    • 0003810746 scopus 로고    scopus 로고
    • Standard Test Methods for Fire Tests of Building Construction and Materials
    • ASTM, ASTM E119, American Society for Testing and Materials, Philadelphia
    • ASTM (1998) Standard Test Methods for Fire Tests of Building Construction and Materials, ASTM E119, American Society for Testing and Materials, Philadelphia.
    • (1998)
  • 53
    • 84889432073 scopus 로고    scopus 로고
    • A Model for Calculating the Probabilities of Flame Spread from Fires in Multi-Storey Buildings
    • Proceedings of the International Conference on Building Envelope Systems and Technologies (ICBEST), Ottawa, Canada, June 2001
    • Benichou, N., Yung, D. and Dutcher, C. (2001) A Model for Calculating the Probabilities of Flame Spread from Fires in Multi-Storey Buildings. Proceedings of the International Conference on Building Envelope Systems and Technologies (ICBEST), Ottawa, Canada, June 2001, pp. 407-11.
    • (2001) , pp. 407-411
    • Benichou, N.1    Yung, D.2    Dutcher, C.3
  • 54
    • 0004093957 scopus 로고    scopus 로고
    • 'Fire Severity' and 'Fire Resistance', in Structural Design for Fire Safety
    • Chapters 5 and 6, John Wiley & Sons Ltd, England
    • Buchanan, A.H. (2001) 'Fire Severity' and 'Fire Resistance', in Structural Design for Fire Safety, Chapters 5 and 6, John Wiley & Sons Ltd, England.
    • (2001)
    • Buchanan, A.H.1
  • 55
    • 84889279989 scopus 로고
    • Actions on Structures Exposed to Fire, Eurocode 1: Basis of Design and Design Actions on Structures, ENV 1991-2-2
    • EC1, European Committee on Standardization, Brussels, Belgium
    • EC1 (1994) Actions on Structures Exposed to Fire, Eurocode 1: Basis of Design and Design Actions on Structures, ENV 1991-2-2, European Committee on Standardization, Brussels, Belgium.
    • (1994)
  • 56
    • 0003740302 scopus 로고
    • Fire Resistance Tests-Elements of Building Construction
    • ISO, ISO 834, International Organization for Standardization, Geneva, Switzerland
    • ISO (1975) Fire Resistance Tests-Elements of Building Construction, ISO 834, International Organization for Standardization, Geneva, Switzerland.
    • (1975)
  • 57
    • 33646677606 scopus 로고    scopus 로고
    • Federal Building and Fire Safety Investigation of the World Trade Center Disaster: Final Report on the Collapse of the World Trade Center Towers
    • NIST, NIST NCSTAR 1, National Institute of Standards and Technology, Gaithersburg
    • NIST (2005) Federal Building and Fire Safety Investigation of the World Trade Center Disaster: Final Report on the Collapse of the World Trade Center Towers, NIST NCSTAR 1, National Institute of Standards and Technology, Gaithersburg.
    • (2005)
  • 58
    • 84889394819 scopus 로고    scopus 로고
    • Thermophysical property data, in SFPE Handbook of Fire Protection Engineering 2002
    • SFPE, 3rd edn, Appendix B, National Fire Protection Association, Quincy, MA
    • SFPE (2002a) Thermophysical property data, in SFPE Handbook of Fire Protection Engineering 2002, 3rd edn, Appendix B, National Fire Protection Association, Quincy, MA.
    • (2002)
  • 59
    • 0842264167 scopus 로고    scopus 로고
    • Analytical methods for determining fire resistance of steel, concrete and timber members, in SFPE Handbook of Fire Protection Engineering 2002
    • SFPE, 3rd edn, Sec. 4, Chapters 9-11, National Fire Protection Association, Quincy, MA
    • SFPE (2002b) Analytical methods for determining fire resistance of steel, concrete and timber members, in SFPE Handbook of Fire Protection Engineering 2002, 3rd edn, Sec. 4, Chapters 9-11, National Fire Protection Association, Quincy, MA.
    • (2002)
  • 60
    • 84889438342 scopus 로고    scopus 로고
    • Normal Distribution
    • Wolfram MathWorld
    • Wolfram MathWorld (2007) Normal Distribution, http://mathworld.wolfram.com/NormalDistribution.html
    • (2007)
  • 61
    • 33846379633 scopus 로고    scopus 로고
    • Numerical study of two air intake strategies for a new fire laboratory
    • Chen, Z.D. and Yung, D. (2007) Numerical study of two air intake strategies for a new fire laboratory. Journal of Fire Protection Engineering, 17(1), 27-40.
    • (2007) Journal of Fire Protection Engineering , vol.17 , Issue.1 , pp. 27-40
    • Chen, Z.D.1    Yung, D.2
  • 62
    • 0013360633 scopus 로고
    • A model for calculating the probabilities of smoke hazard from fires in multi-storey buildings
    • Hadjisophocleous, G.V. and Yung, D. (1992) A model for calculating the probabilities of smoke hazard from fires in multi-storey buildings. Journal of Fire Protection Engineering, 4(2), 67-80.
    • (1992) Journal of Fire Protection Engineering , vol.4 , Issue.2 , pp. 67-80
    • Hadjisophocleous, G.V.1    Yung, D.2
  • 63
    • 6244278130 scopus 로고
    • Experiments to validate the NRCC smoke movement model for fire risk-cost assessment
    • Proceedings of the Fourth International Symposium on Fire Safety Science, Ottawa, Canada, June 1994
    • Hokugo, A., Yung, D. and Hadjisophocleous, G.V. (1994) Experiments to validate the NRCC smoke movement model for fire risk-cost assessment, Proceedings of the Fourth International Symposium on Fire Safety Science, Ottawa, Canada, June 1994, pp. 805-16.
    • (1994) , pp. 805-816
    • Hokugo, A.1    Yung, D.2    Hadjisophocleous, G.V.3
  • 64
    • 84889091111 scopus 로고    scopus 로고
    • Smoke control, in SFPE Handbook of Fire Protection Engineering 2002
    • 3rd edn, Section 4, Chapter 12, National Fire Protection Association, Quincy, MA
    • Klote, J.H. (2002) Smoke control, in SFPE Handbook of Fire Protection Engineering 2002, 3rd edn, Section 4, Chapter 12, National Fire Protection Association, Quincy, MA.
    • (2002)
    • Klote, J.H.1
  • 65
    • 0037773268 scopus 로고    scopus 로고
    • Fire Dynamics Simulator (Version 4): user's Guide, NIST Special Publication 1019
    • National Institute of Standards and Technology, Gaithersburg, MD
    • McGrattan, K.B. and Forney, G. (2006) Fire Dynamics Simulator (Version 4): user's Guide, NIST Special Publication 1019, National Institute of Standards and Technology, Gaithersburg, MD.
    • (2006)
    • McGrattan, K.B.1    Forney, G.2
  • 66
    • 0038630559 scopus 로고    scopus 로고
    • An updated international survey of computer models for fire and smoke
    • Olenick, S.M. and Carpenter, D.J. (2003) An updated international survey of computer models for fire and smoke. Journal of Fire Protection Engineering, 13(2), 87-110.
    • (2003) Journal of Fire Protection Engineering , vol.13 , Issue.2 , pp. 87-110
    • Olenick, S.M.1    Carpenter, D.J.2
  • 67
    • 34547238708 scopus 로고    scopus 로고
    • CFAST: Consolidated Model of Fire Growth and Smoke Transport (Version 6): user's Guide
    • NIST Special Publication 1041, National Institute of Standards and Technology, August 2005, Gaithersburg, MD
    • Peacock, R.D.,Jones, W.W., Reneke, P.A. and Forney, G.P. (2005) CFAST: Consolidated Model of Fire Growth and Smoke Transport (Version 6): user's Guide, NIST Special Publication 1041, National Institute of Standards and Technology, August 2005, Gaithersburg, MD.
    • (2005)
    • Peacock, R.D.1    Jones, W.W.2    Reneke, P.A.3    Forney, G.P.4
  • 68
    • 84889418092 scopus 로고    scopus 로고
    • Concentration, Heat and Momentum Limited (CHAM)
    • PHOENICS on-line information, Wimbledon, U.K.
    • PHOENICS on-line information (2007) Concentration, Heat and Momentum Limited (CHAM), Wimbledon, U.K., http://www.cham.co.uk/website/new/phoenic2.htm.
    • (2007)
  • 69
    • 84889383831 scopus 로고    scopus 로고
    • Thermophysical property values for gases at standard atmospheric pressure, in SFPE Handbook of Fire Protection Engineering 2002
    • SFPE, 3rd edn, Table B.2, National Fire Protection Association, Quincy, MA
    • SFPE (2002) Thermophysical property values for gases at standard atmospheric pressure, in SFPE Handbook of Fire Protection Engineering 2002, 3rd edn, Table B.2, National Fire Protection Association, Quincy, MA, pp. A23-A24.
    • (2002)
  • 70
    • 0003654754 scopus 로고
    • Smoke Movement and Control in Highrise Buildings
    • National Fire Protection Association, Quincy, MA
    • Tamura, G.T. (1994) Smoke Movement and Control in Highrise Buildings, National Fire Protection Association, Quincy, MA.
    • (1994)
    • Tamura, G.T.1
  • 71
    • 33744793435 scopus 로고    scopus 로고
    • U.S. Experience with Smoke Alarms and Other Fire detection/Alarm Equipment
    • NFPA Report, April 2007, National Fire Protection Association, Quincy, MA. Tables 8-9, 26C-32C, 34C-36C
    • Ahrens, M. (2007) U.S. Experience with Smoke Alarms and Other Fire detection/Alarm Equipment, NFPA Report, April 2007, National Fire Protection Association, Quincy, MA. Tables 8-9, 26C-32C, 34C-36C.
    • (2007)
    • Ahrens, M.1
  • 72
    • 84889477832 scopus 로고    scopus 로고
    • Guide to design framework and fire safety engineering procedures
    • BSI, Application of Fire Safety Engineering Principles to the Design of Buildings, PD7974-0, 2002, Part 0, British Standards Institution, London
    • BSI (2002) Guide to design framework and fire safety engineering procedures, Application of Fire Safety Engineering Principles to the Design of Buildings, PD7974-0, 2002, Part 0, British Standards Institution, London, p. 30.
    • (2002) , pp. 30
  • 73
    • 10444278426 scopus 로고    scopus 로고
    • Performance ofHome Smoke Alarms-Analysis of the Response of Several Available Technologies in Residential Fire Settings
    • NIST Technical Note 1455, January 2007, National Institute of Standards and Technology, Gaithersburg, MD, Tables 23-24
    • Bukowski, R.W., Peacock, R.D., Averill, J.D. et al. (2007) Performance ofHome Smoke Alarms-Analysis of the Response of Several Available Technologies in Residential Fire Settings, NIST Technical Note 1455, January 2007, National Institute of Standards and Technology, Gaithersburg, MD, Tables 23-24.
    • (2007)
    • Bukowski, R.W.1    Peacock, R.D.2    Averill, J.D.3
  • 74
    • 0013368605 scopus 로고    scopus 로고
    • Occupant Evacuation Model for Apartment and Office Buildings
    • National Research Council Canada Internal Report No. 741, Ottawa, May 1997
    • Hadjisophocleous, G.V., Proulx, G. and Liu, Q. (1997) Occupant Evacuation Model for Apartment and Office Buildings, National Research Council Canada Internal Report No. 741, Ottawa, May 1997, 19 pages.
    • (1997) , pp. 19
    • Hadjisophocleous, G.V.1    Proulx, G.2    Liu, Q.3
  • 75
    • 80455122884 scopus 로고
    • Parametric Study of the NRCC Fire Risk-Cost Assessment Model for Apartment and Office Buildings
    • Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa
    • Hadjisophocleous, G.V. and Yung, D. (1994) Parametric Study of the NRCC Fire Risk-Cost Assessment Model for Apartment and Office Buildings. Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa, pp. 829-40.
    • (1994) , pp. 829-840
    • Hadjisophocleous, G.V.1    Yung, D.2
  • 77
    • 80455141273 scopus 로고    scopus 로고
    • Design of Occupant Egress Systems for Tall Buildings
    • Proceedings of the CIB World Building Congress 2004, CIB HTB T3S1 Design for Fire Safety, May 2004, Toronto
    • Kuligowski, E.D. and Bukowski, R.W. (2004) Design of Occupant Egress Systems for Tall Buildings. Proceedings of the CIB World Building Congress 2004, CIB HTB T3S1 Design for Fire Safety, May 2004, Toronto, pp. 1-11.
    • (2004) , pp. 1-11
    • Kuligowski, E.D.1    Bukowski, R.W.2
  • 78
    • 54049128758 scopus 로고    scopus 로고
    • Response to fire alarms
    • Fire Protection Engineering Magazine, Winter 8-14
    • Proulx, G. (2007) Response to fire alarms. Fire Protection Engineering Magazine, Winter 8-14.
    • (2007)
    • Proulx, G.1
  • 79
    • 84856113222 scopus 로고    scopus 로고
    • Evaluation of the Effectiveness of Different Photoluminescent Stairwell Installations for the Evacuation of Office Building Occupants
    • Research Report 232, Institute for Research in Construction, National Research Council Canada, July 6, 2007
    • Proulx, G., Benichou, N., Hum, J.K. and Restivo, K.N. (2007) Evaluation of the Effectiveness of Different Photoluminescent Stairwell Installations for the Evacuation of Office Building Occupants, Research Report 232, Institute for Research in Construction, National Research Council Canada, pp. 77, July 6, 2007, URL: http://irc.nrc-cnrc.gc.ca/pubs/rr/rr232/.
    • (2007) , pp. 77
    • Proulx, G.1    Benichou, N.2    Hum, J.K.3    Restivo, K.N.4
  • 80
    • 0013455918 scopus 로고
    • Occupant Response Model: A Sub-Model for the NRCC Risk-Cost Assessment Model
    • Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa
    • Proulx, G. and Hadjisophocleous, G.V. (1994) Occupant Response Model: A Sub-Model for the NRCC Risk-Cost Assessment Model. Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa, pp. 841-52.
    • (1994) , pp. 841-852
    • Proulx, G.1    Hadjisophocleous, G.V.2
  • 81
    • 84889346587 scopus 로고    scopus 로고
    • Evacuation Procedures for Occupants with Disabilities in Highrise Buildings
    • Proceedings of WOBO Fourth World Congress, November 1996, Hong Kong
    • Proulx, G. and Yung, D. (1996) Evacuation Procedures for Occupants with Disabilities in Highrise Buildings. Proceedings of WOBO Fourth World Congress, November 1996, Hong Kong, pp. 1-10.
    • (1996) , pp. 1-10
    • Proulx, G.1    Yung, D.2
  • 82
    • 84889339251 scopus 로고    scopus 로고
    • Human behavior in fire, SFPE Engineering Guide
    • SFPE EG, Society of Fire Protection Engineers, Bethesda, MD
    • SFPE EG (2003) Human behavior in fire, SFPE Engineering Guide, Society of Fire Protection Engineers, Bethesda, MD, 30 pages.
    • (2003) , pp. 30
  • 83
    • 0002835203 scopus 로고    scopus 로고
    • Behavioral response to fire and smoke, SFPE Handbook of Fire Protection Engineering
    • SFPE HB, 3rd edn, National Fire Protection Association, Quincy, MA, Table 3-12.20
    • SFPE HB (2002a) Behavioral response to fire and smoke, SFPE Handbook of Fire Protection Engineering, 3rd edn, National Fire Protection Association, Quincy, MA, Table 3-12.20, p. 3-334.
    • (2002) , pp. 3-334
  • 84
    • 0002251150 scopus 로고    scopus 로고
    • Design of detection systems, SFPE Handbook of Fire Protection Engineering
    • SFPE HB, 3rd edn, National Fire Protection Association, Quincy, MA, Sec 4
    • SFPE HB (2002b) Design of detection systems, SFPE Handbook of Fire Protection Engineering, 3rd edn, National Fire Protection Association, Quincy, MA, Sec 4, pp. 4-1-4-43.
    • (2002)
  • 85
    • 57649242705 scopus 로고    scopus 로고
    • Emergency movement, SFPE Handbook of Fire Protection Engineering
    • SFPE HB, 3rd edn, National Fire Protection Association, Quincy, MA, Equation 3 and Table 3-14.2, Emergency Movement Models
    • SFPE HB (2002c) Emergency movement, SFPE Handbook of Fire Protection Engineering, 3rd edn, National Fire Protection Association, Quincy, MA, Equation 3 and Table 3-14.2, p. 3-370, Emergency Movement Models, p. 3-377.
    • (2002)
  • 86
    • 84861196994 scopus 로고    scopus 로고
    • Movement of people: the evacuation timing, SFPE Handbook of Fire Protection Engineering
    • SFPE HB, 3rd edn, National Fire Protection Association, Quincy, MA, Table 3-13.1, Table 3-13.5
    • SFPE HB (2002d) Movement of people: the evacuation timing, SFPE Handbook of Fire Protection Engineering, 3rd edn, National Fire Protection Association, Quincy, MA, Table 3-13.1, p. 3-351, Table 3-13.5, p. 3-363.
    • (2002)
  • 87
    • 0001542826 scopus 로고    scopus 로고
    • Smoke production and properties, SFPE Handbook of Fire Protection Engineering
    • SFPE HB, 3rd edn, National Fire Protection Association, Quincy, MA, Sec 2-13
    • SFPE HB (2002e) Smoke production and properties, SFPE Handbook of Fire Protection Engineering, 3rd edn, National Fire Protection Association, Quincy, MA, Sec 2-13, p. 2-263.
    • (2002) , pp. 2-263
  • 88
    • 0004485153 scopus 로고    scopus 로고
    • Toxicity assessment of combustion products, SFPE Handbook of Fire Protection Engineering
    • SFPE HB, 3rd edn, National Fire Protection Association, Quincy, MA, Table 2-6.18
    • SFPE HB (2002f) Toxicity assessment of combustion products, SFPE Handbook of Fire Protection Engineering, 3rd edn, National Fire Protection Association, Quincy, MA, Table 2-6.18, p. 2-127.
    • (2002) , pp. 2-127
  • 89
    • 84889458926 scopus 로고
    • Simulex: Developing New Techniques for Modelling Evacuation
    • Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa
    • Thompson, P.A. and Marchant, E.W. (1994) Simulex: Developing New Techniques for Modelling Evacuation. Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa, pp. 613-24.
    • (1994)
    • Thompson, P.A.1    Marchant, E.W.2
  • 90
    • 0004618827 scopus 로고    scopus 로고
    • Modelling Concepts for the Risk-Cost Assessment Model FiRECAM and its Application to a Canadian Government Office Building
    • Proceedings of the Fifth International Symposium on Fire Safety Science, March 1997, Melbourne
    • Yung, D., Hadjisophocleous, G.V. and Proulx, G. (1997) Modelling Concepts for the Risk-Cost Assessment Model FiRECAM and its Application to a Canadian Government Office Building. Proceedings of the Fifth International Symposium on Fire Safety Science, March 1997, Melbourne, pp. 619-30.
    • (1997) , pp. 619-630
    • Yung, D.1    Hadjisophocleous, G.V.2    Proulx, G.3
  • 91
    • 80051483858 scopus 로고    scopus 로고
    • Comparison of Model Predictions and Actual Experience of Occupant Response and Evacuation in Two Highrise Apartment Building Fires
    • Proceedings of the Second International Symposium on Human Behaviour in Fire, M.I.T., BostonMarch 2001
    • Yung, D. Proulx, G. and Benichou, N. (2001) Comparison of Model Predictions and Actual Experience of Occupant Response and Evacuation in Two Highrise Apartment Building Fires. Proceedings of the Second International Symposium on Human Behaviour in Fire, M.I.T., BostonMarch 2001, pp. 77-88.
    • (2001) , pp. 77-88
    • Yung, D.1    Proulx, G.2    Benichou, N.3
  • 92
    • 0013362225 scopus 로고    scopus 로고
    • Impact of Fire Department Response and Mandatory Sprinkler Protection on Life Risks in ResidentialCommunities
    • Proceedings of Interflam'99, July 1999, Edinburgh, Scotland
    • Benichou, N., Yung, D. and Hadjisophocleous, G.V. (1999) Impact of Fire Department Response and Mandatory Sprinkler Protection on Life Risks in ResidentialCommunities, Proceedings of Interflam'99, July 1999, Edinburgh, Scotland, pp. 521-32.
    • (1999) , pp. 521-532
    • Benichou, N.1    Yung, D.2    Hadjisophocleous, G.V.3
  • 93
    • 84889301723 scopus 로고    scopus 로고
    • Fire service intervention, Part 5, Application of Fire Safety Engineering Principles to the Design of Buildings
    • BSI, PD7974-5, British Standards Institution, London, UK
    • BSI (2002), Fire service intervention, Part 5, Application of Fire Safety Engineering Principles to the Design of Buildings, PD7974-5, British Standards Institution, London, UK, p. 11.
    • (2002) , pp. 11
  • 94
    • 84889495838 scopus 로고    scopus 로고
    • Fighting Fire with F.I.R.E.-New technology Improves First Responder Communication
    • Berkeley Science Review, (12), Spring
    • Dill, J. (2007) Fighting Fire with F.I.R.E.-New technology Improves First Responder Communication, Berkeley Science Review, (12), Spring, 18-19.
    • (2007) , pp. 18-19
    • Dill, J.1
  • 95
    • 0013364881 scopus 로고
    • Canadian and U.S.A. Fire Statistics for Use in the Risk-Cost Assessment Model
    • IRC Internal Report No. 637, National Research Council Canada, January 1993, Ottawa, Canada
    • Gaskin, J. and Yung, D. (1993) Canadian and U.S.A. Fire Statistics for Use in the Risk-Cost Assessment Model, IRC Internal Report No. 637, National Research Council Canada, January 1993, Ottawa, Canada, 18 pages.
    • (1993) , pp. 18
    • Gaskin, J.1    Yung, D.2
  • 96
    • 0013360633 scopus 로고
    • A model for calculating the probabilities of smoke hazard from fires in multi-storey buildings
    • Hadjisophocleous, G.V. and Yung, D. (1992) A model for calculating the probabilities of smoke hazard from fires in multi-storey buildings. Journal of Fire Protection Engineering, 4(2), 67-80.
    • (1992) Journal of Fire Protection Engineering , vol.4 , Issue.2 , pp. 67-80
    • Hadjisophocleous, G.V.1    Yung, D.2
  • 97
    • 80455122884 scopus 로고
    • Parametric Study of the NRCC Fire Risk-Cost Assessment Model for Apartment and Office Buildings
    • Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa, Canada
    • Hadjisophocleous, G.V. and Yung, D. (1994) Parametric Study of the NRCC Fire Risk-Cost Assessment Model for Apartment and Office Buildings, Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa, Canada, 829-40.
    • (1994) , pp. 829-840
    • Hadjisophocleous, G.V.1    Yung, D.2
  • 98
    • 0035401393 scopus 로고    scopus 로고
    • Development and application of the fire brigade intervention model
    • Merchant, R., Kurban, N. and Wise, S. (2001) Development and application of the fire brigade intervention model. Fire Technology, 37(3), 263-78.
    • (2001) Fire Technology , vol.37 , Issue.3 , pp. 263-278
    • Merchant, R.1    Kurban, N.2    Wise, S.3
  • 99
    • 0013455918 scopus 로고
    • Occupant Response Model: A Sub-Model for the NRCC Risk-Cost Assessment Model
    • Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa, Canada
    • Proulx, G. and Hadjisophocleous, G.V. (1994) Occupant Response Model: A Sub-Model for the NRCC Risk-Cost Assessment Model, Proceedings of the Fourth International Symposium on Fire Safety Science, June 1994, Ottawa, Canada, pp. 841-52.
    • (1994) , pp. 841-852
    • Proulx, G.1    Hadjisophocleous, G.V.2
  • 100
    • 0004485153 scopus 로고    scopus 로고
    • Toxicity assessment of combustion products, SFPE Handbook of Fire Protection Engineering 2002
    • 3rd edn, Section 2: Chapter 6, National Fire Protection Association, Quincy, MA
    • Purser, D.A. (2002) Toxicity assessment of combustion products, SFPE Handbook of Fire Protection Engineering 2002, 3rd edn, Section 2: Chapter 6, National Fire Protection Association, Quincy, MA.
    • (2002)
    • Purser, D.A.1
  • 101
    • 0035401395 scopus 로고    scopus 로고
    • Estimating water requirements for firefighting operations using FIERAsystem
    • Torvi, D.A., Hadjisophocleous, G.V. and Guenther, M.B. (2001) Estimating water requirements for firefighting operations using FIERAsystem. Fire Technology, 37(3), 235-62.
    • (2001) Fire Technology , vol.37 , Issue.3 , pp. 235-262
    • Torvi, D.A.1    Hadjisophocleous, G.V.2    Guenther, M.B.3
  • 102
    • 84889383331 scopus 로고    scopus 로고
    • Structure fire response times
    • U.S. Fire Administration/National Fire Data Center, August 2006
    • U.S. Fire Administration/National Fire Data Center (2006) Structure fire response times. Topical Fire Research Series, 5(7), August 2006, 5 pages.
    • (2006) Topical Fire Research Series , vol.5 , Issue.7 , pp. 5
  • 103
    • 0036667171 scopus 로고    scopus 로고
    • How design fires can be used in fire hazard analysis
    • Yung, D. and Benichou, N. (2002) How design fires can be used in fire hazard analysis. Fire Technology, 38(3), 231-42.
    • (2002) Fire Technology , vol.38 , Issue.3 , pp. 231-242
    • Yung, D.1    Benichou, N.2
  • 104
    • 0004618827 scopus 로고    scopus 로고
    • Modelling Concepts for the Risk-Cost Assessment Model FiRECAM and Its Application to a Canadian Government Office Building
    • Proceedings of the Fifth International Symposium on Fire Safety Science, March 1997, Melbourne, Australia
    • Yung, D., Hadjisophocleous, G.V. and Proulx, G. (1997) Modelling Concepts for the Risk-Cost Assessment Model FiRECAM and Its Application to a Canadian Government Office Building, Proceedings of the Fifth International Symposium on Fire Safety Science, March 1997, Melbourne, Australia, pp. 619-30.
    • (1997) , pp. 619-630
    • Yung, D.1    Hadjisophocleous, G.V.2    Proulx, G.3
  • 105
    • 0011701036 scopus 로고    scopus 로고
    • Derivation of Partial Safety Factors for Fire Safety Evaluation Using the Reliability Index β Method
    • Proceedings of the Fifth International Symposium on Fire Safety Science, March 1997, Melbourne
    • Frantzich, H., Magnusson, S.E., Holquist, B. and Ryden, J. (1997) Derivation of Partial Safety Factors for Fire Safety Evaluation Using the Reliability Index β Method. Proceedings of the Fifth International Symposium on Fire Safety Science, March 1997, Melbourne, pp. 667-78.
    • (1997) , pp. 667-678
    • Frantzich, H.1    Magnusson, S.E.2    Holquist, B.3    Ryden, J.4
  • 106
    • 80455122884 scopus 로고
    • Parametric Study of the NRCC Risk-Cost AssessmentModel for Apartment and Office Buildings
    • Proceedings of the 4th International Symposium on Fire Safety Science, June 1994, Ottawa
    • Hadjisophocleous, G.V. and Yung, D. (1994) Parametric Study of the NRCC Risk-Cost AssessmentModel for Apartment and Office Buildings. Proceedings of the 4th International Symposium on Fire Safety Science, June 1994, Ottawa, pp. 829-40.
    • (1994) , pp. 829-840
    • Hadjisophocleous, G.V.1    Yung, D.2
  • 108
    • 0036852743 scopus 로고    scopus 로고
    • Response surface modelling of monte carlo fire data
    • Hasofer, A.M. and Qu, J. (2002) Response surface modelling of monte carlo fire data. Fire Safety Journal, 37, 772-84.
    • (2002) Fire Safety Journal , vol.37 , pp. 772-784
    • Hasofer, A.M.1    Qu, J.2
  • 109
    • 84873643832 scopus 로고    scopus 로고
    • Uncertainty, SFPE Handbook of Fire Protection Engineering
    • 3rd edn, Section 5: Chapter 4, National Fire Protection Association, Quincy, MA
    • Notarianni, K.A. (2002) Uncertainty, SFPE Handbook of Fire Protection Engineering, 3rd edn, Section 5: Chapter 4, National Fire Protection Association, Quincy, MA.
    • (2002)
    • Notarianni, K.A.1
  • 110
    • 0004633362 scopus 로고    scopus 로고
    • Performance-based Fire Engineering Design and its Application in Australia
    • Proceedings of the Fifth International Symposium on Fire Safety Science, Melbourne, Australia, March 1997
    • Beck, V. (1997) Performance-based Fire Engineering Design and its Application in Australia, Proceedings of the Fifth International Symposium on Fire Safety Science, Melbourne, Australia, March 1997, pp. 23-40.
    • (1997) , pp. 23-40
    • Beck, V.1
  • 111
    • 0025451028 scopus 로고
    • A cost-effective risk assessment model for evaluating fire safety and protection in Canadian apartment buildings
    • Beck, V.R. and Yung, D. (1990) A cost-effective risk assessment model for evaluating fire safety and protection in Canadian apartment buildings. Journal of Fire Protection Engineering, 2(3), 65-74.
    • (1990) Journal of Fire Protection Engineering , vol.2 , Issue.3 , pp. 65-74
    • Beck, V.R.1    Yung, D.2
  • 112
    • 25444489290 scopus 로고    scopus 로고
    • FIERAsystem: a fire risk assessment tool to evaluate fire safety in industrial buildings and large spaces
    • Benichou, N., Kashef, A.H., Reid, I. et al. (2005) FIERAsystem: a fire risk assessment tool to evaluate fire safety in industrial buildings and large spaces. Journal of Fire Protection Engineering, 15(3), 145-72.
    • (2005) Journal of Fire Protection Engineering , vol.15 , Issue.3 , pp. 145-172
    • Benichou, N.1    Kashef, A.H.2    Reid, I.3
  • 113
    • 0013362225 scopus 로고    scopus 로고
    • Impact of Fire Department Response and Mandatory Sprinkler Protection on Life Risks in Residential Communities
    • Proceedings of Interflam '99, Edinburgh, Scotland, July 1999
    • Benichou, N., Yung, D. and Hadjisophocleous, G.V. (1999) Impact of Fire Department Response and Mandatory Sprinkler Protection on Life Risks in Residential Communities, Proceedings of Interflam '99, Edinburgh, Scotland, July 1999, pp. 521-32.
    • (1999) , pp. 521-532
    • Benichou, N.1    Yung, D.2    Hadjisophocleous, G.V.3
  • 114
    • 84889336969 scopus 로고    scopus 로고
    • Reliability of fire alarm systems, Fire Protection Engineering Magazine
    • Society of Fire Protection Engineers, Bethesda, MD, Winter 2007 edition
    • Dungan, K.W. (2007) Reliability of fire alarm systems, Fire Protection Engineering Magazine, Society of Fire Protection Engineers, Bethesda, MD, Winter 2007 edition, pp. 38-48.
    • (2007) , pp. 38-48
    • Dungan, K.W.1
  • 115
    • 84889090371 scopus 로고    scopus 로고
    • Commissioning smoke control systems, Fire Protection Engineering Magazine
    • Society of Fire Protection Engineers, Bethesda, MD, Fall 2006 edition
    • Elovitz, K.M. (2006) Commissioning smoke control systems, Fire Protection Engineering Magazine, Society of Fire Protection Engineers, Bethesda, MD, Fall 2006 edition, pp. 28-40.
    • (2006) , pp. 28-40
    • Elovitz, K.M.1
  • 116
    • 84889089457 scopus 로고    scopus 로고
    • Fire Risk Evaluation and Cost Assessment Model
    • FiRECAM, National Research Council Canada
    • FiRECAM (2008) Fire Risk Evaluation and Cost Assessment Model, National Research Council Canada, http://irc.nrc-cnrc.gc.ca/fr/frhb/firecamnew e.html
    • (2008)
  • 117
    • 77958485479 scopus 로고    scopus 로고
    • Reliability study on sprinkler system to be installed in old high-rise buildings
    • Fong, N.K. (2000) Reliability study on sprinkler system to be installed in old high-rise buildings. International Journal on Engineering Performance-Based Codes, 2(2), 61-67.
    • (2000) International Journal on Engineering Performance-Based Codes , vol.2 , Issue.2 , pp. 61-67
    • Fong, N.K.1
  • 118
    • 84889461037 scopus 로고    scopus 로고
    • Reliability, SFPE Handbook of Fire Protection Engineering 2002
    • 3rd edn, Section 5: Chapter 3, National Fire Protection Association, Quincy, MA
    • Modarres, M. and Joglar-Billoch, F. (2002) Reliability, SFPE Handbook of Fire Protection Engineering 2002, 3rd edn, Section 5: Chapter 3, National Fire Protection Association, Quincy, MA.
    • (2002)
    • Modarres, M.1    Joglar-Billoch, F.2
  • 119
    • 33645260562 scopus 로고    scopus 로고
    • History of Fire Protection Engineering
    • National Fire Protection Association, Quincy, MA
    • Richardson, J.K. (ed) (2003) History of Fire Protection Engineering, National Fire Protection Association, Quincy, MA, pp. 274-75.
    • (2003) , pp. 274-275
    • Richardson, J.K.1
  • 120
    • 12944326969 scopus 로고
    • Building fire safety risk analysis, SFPE Handbook of Fire Protection Engineering 1995
    • 2nd edn, Section 5: Chapter 11, National Fire Protection Association, Quincy, MA
    • Yung, D. and Beck, V.R. (1995), Building fire safety risk analysis, SFPE Handbook of Fire Protection Engineering 1995, 2nd edn, Section 5: Chapter 11, National Fire Protection Association, Quincy, MA.
    • (1995)
    • Yung, D.1    Beck, V.R.2
  • 121
    • 84889310346 scopus 로고    scopus 로고
    • Assessment of the Impact of Reliability of Fire Alarms and Automatic Sprinklers on Life Safety in Buildings
    • Proceedings of the 2nd Fire Risk and Hazard Assessment Research Application Symposium, San Francisco, California, June 25-27, 1997
    • Yung, D. and Hadjisophocleous, G.V. (1997) Assessment of the Impact of Reliability of Fire Alarms and Automatic Sprinklers on Life Safety in Buildings, Proceedings of the 2nd Fire Risk and Hazard Assessment Research Application Symposium, San Francisco, California, June 25-27, 1997, pp. 132-41.
    • (1997) , pp. 132-141
    • Yung, D.1    Hadjisophocleous, G.V.2
  • 122
    • 0004618827 scopus 로고    scopus 로고
    • Modelling Concepts for the Risk-Cost Assessment Model FiRECAM and Its Application to a Canadian Government Office Building
    • Proceedings of the Fifth International Symposium on Fire Safety Science, Melbourne, Australia, March 1997
    • Yung, D., Hadjisophocleous, G.V. and Proulx, G. (1997), Modelling Concepts for the Risk-Cost Assessment Model FiRECAM and Its Application to a Canadian Government Office Building, Proceedings of the Fifth International Symposium on Fire Safety Science, Melbourne, Australia, March 1997, pp. 619-30.
    • (1997) , pp. 619-630
    • Yung, D.1    Hadjisophocleous, G.V.2    Proulx, G.3
  • 123
    • 84555172044 scopus 로고    scopus 로고
    • Case Study: The Use of FiRECAM to Identify Cost-Effective Fire Safety Design Options for a Large 40-Storey Office Building
    • Proceedings of the 1998 Pacific Rim Conference and 2nd International Conference on Performance-Based Codes and Fire Safety Design Methods, May 3-9, 1998, Maui, Hawaii
    • Yung, D., Hadjisophocleous, G.V. and Yager, B. (1998) Case Study: The Use of FiRECAM to Identify Cost-Effective Fire Safety Design Options for a Large 40-Storey Office Building, Proceedings of the 1998 Pacific Rim Conference and 2nd International Conference on Performance-Based Codes and Fire Safety Design Methods, May 3-9, 1998, Maui, Hawaii, pp. 441-52.
    • (1998) , pp. 441-452
    • Yung, D.1    Hadjisophocleous, G.V.2    Yager, B.3
  • 124
    • 0242440894 scopus 로고    scopus 로고
    • The Definition of Scenarios for the CESARE-RISK Model
    • Proceedings of the Fifth International Symposium on Fire Safety Science, March 1997, Melbourne, Australia
    • Zhao, L. and Beck, V. (1997) The Definition of Scenarios for the CESARE-RISK Model, Proceedings of the Fifth International Symposium on Fire Safety Science, March 1997, Melbourne, Australia, pp. 655-66.
    • (1997) , pp. 655-666
    • Zhao, L.1    Beck, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.