-
2
-
-
4544307155
-
Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model
-
Prosi M., Perkold K., Ding Z., and Friedman M.H. Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model. J Biomech 37 (2004) 1767-1775
-
(2004)
J Biomech
, vol.37
, pp. 1767-1775
-
-
Prosi, M.1
Perkold, K.2
Ding, Z.3
Friedman, M.H.4
-
3
-
-
34248232585
-
Compliant biomechanics of abdominal aortic aneurysms: a fluid-structure interaction study
-
Scotti C.M., and Finol E.A. Compliant biomechanics of abdominal aortic aneurysms: a fluid-structure interaction study. Comput Struct 85 (2007) 1097-1113
-
(2007)
Comput Struct
, vol.85
, pp. 1097-1113
-
-
Scotti, C.M.1
Finol, E.A.2
-
4
-
-
0037212420
-
A three-dimensional computational analysis of fluid-structure interaction in the aortic valve
-
De Hart J., Peters G.W.M., Schreus P.J.G., and Baaijens F.P.T. A three-dimensional computational analysis of fluid-structure interaction in the aortic valve. J Biomech 36 (2003) 103-106
-
(2003)
J Biomech
, vol.36
, pp. 103-106
-
-
De Hart, J.1
Peters, G.W.M.2
Schreus, P.J.G.3
Baaijens, F.P.T.4
-
5
-
-
3042702301
-
Evaluation of a fictitious domain method for predicting dynamic response of mechanical heart valve
-
Stijnen J.M.A., De Hart J., Bovendeerd P.H.M., and Van de Vosse F.N. Evaluation of a fictitious domain method for predicting dynamic response of mechanical heart valve. J Fluids Struct 19 (2004) 835-850
-
(2004)
J Fluids Struct
, vol.19
, pp. 835-850
-
-
Stijnen, J.M.A.1
De Hart, J.2
Bovendeerd, P.H.M.3
Van de Vosse, F.N.4
-
6
-
-
33846293260
-
Dynamics modelling of prosthetic chorded mitral valves using the immersed boundary method
-
Watton P.N., Luo X.Y., Wang X., Bernacca G.M., Molloy P., and Wheatley D.J. Dynamics modelling of prosthetic chorded mitral valves using the immersed boundary method. J Biomech 40 (2007) 613-626
-
(2007)
J Biomech
, vol.40
, pp. 613-626
-
-
Watton, P.N.1
Luo, X.Y.2
Wang, X.3
Bernacca, G.M.4
Molloy, P.5
Wheatley, D.J.6
-
7
-
-
14344255428
-
Validation of a fluid-structure interaction model of a heart valve using the dynamic mesh method in fluent
-
Dumont K., Stijnen J.M.A., Vierendeels J., Van de Vosse F.N., and Verdonck P.R. Validation of a fluid-structure interaction model of a heart valve using the dynamic mesh method in fluent. Comput Meth Biomech Biomed Eng 7 (2004) 139-146
-
(2004)
Comput Meth Biomech Biomed Eng
, vol.7
, pp. 139-146
-
-
Dumont, K.1
Stijnen, J.M.A.2
Vierendeels, J.3
Van de Vosse, F.N.4
Verdonck, P.R.5
-
8
-
-
48149108571
-
Numerical simulation of the dynamics of a bileaflet prosthetic heart valve using a fluid-structure interaction approach
-
Nobili M., Morbiducci U., Ponzini R., Del Gaudio C., Balducci A., Grigioni M., Montevecchi F.M., and Redaelli A. Numerical simulation of the dynamics of a bileaflet prosthetic heart valve using a fluid-structure interaction approach. J Biomech 41 (2008) 2539-2550
-
(2008)
J Biomech
, vol.41
, pp. 2539-2550
-
-
Nobili, M.1
Morbiducci, U.2
Ponzini, R.3
Del Gaudio, C.4
Balducci, A.5
Grigioni, M.6
Montevecchi, F.M.7
Redaelli, A.8
-
9
-
-
27744577368
-
An approach to the simulation of fluid-structure interaction in the aortic valve
-
Carmody C.J., Burriesci G., Howard I.C., and Patterson E.A. An approach to the simulation of fluid-structure interaction in the aortic valve. J Biomech 39 (2006) 158-169
-
(2006)
J Biomech
, vol.39
, pp. 158-169
-
-
Carmody, C.J.1
Burriesci, G.2
Howard, I.C.3
Patterson, E.A.4
-
10
-
-
7444219595
-
3D simulation of the St Jude Medical bileaflet valve opening process: fluid-structure interaction study and experimental validation
-
Redaelli A., Bothorel H., Votta E., Soncini M., Morbiducci U., Del Gaudio C., Balducci A., and Grigioni M. 3D simulation of the St Jude Medical bileaflet valve opening process: fluid-structure interaction study and experimental validation. J Heart Valve Dis 13 (2004) 804-813
-
(2004)
J Heart Valve Dis
, vol.13
, pp. 804-813
-
-
Redaelli, A.1
Bothorel, H.2
Votta, E.3
Soncini, M.4
Morbiducci, U.5
Del Gaudio, C.6
Balducci, A.7
Grigioni, M.8
-
11
-
-
0010502787
-
Valvular heart disease and prosthetic valve evaluation
-
Weinberg R. (Ed), Lippincott Williams and Wilkins, Philadelphia
-
Oh J.K., Seward J.B., and Tajik A.J. Valvular heart disease and prosthetic valve evaluation. In: Weinberg R. (Ed). The echo manual. 2nd ed. (1999), Lippincott Williams and Wilkins, Philadelphia 103-143
-
(1999)
The echo manual. 2nd ed.
, pp. 103-143
-
-
Oh, J.K.1
Seward, J.B.2
Tajik, A.J.3
-
12
-
-
0016334717
-
Dimensions and geometric relationships of the human aortic value as a function of pressure
-
Swanson W.M., and Clark R.E. Dimensions and geometric relationships of the human aortic value as a function of pressure. Circ Res 35 (1974) 871-882
-
(1974)
Circ Res
, vol.35
, pp. 871-882
-
-
Swanson, W.M.1
Clark, R.E.2
-
13
-
-
0001767319
-
Oscillatory motion of a viscous liquid in a thin-walled elastic tube
-
Womersley J. Oscillatory motion of a viscous liquid in a thin-walled elastic tube. Philos Mag 46 (1955) 199-221
-
(1955)
Philos Mag
, vol.46
, pp. 199-221
-
-
Womersley, J.1
-
14
-
-
34250811972
-
New insights into the assessment of the prosthetic valve performance in the presence of a subaortic stenosis through a fluid-structure interaction model
-
Guivier C., Deplano V., and Pibarot P. New insights into the assessment of the prosthetic valve performance in the presence of a subaortic stenosis through a fluid-structure interaction model. J Biomech 40 (2007) 2283-2290
-
(2007)
J Biomech
, vol.40
, pp. 2283-2290
-
-
Guivier, C.1
Deplano, V.2
Pibarot, P.3
-
15
-
-
3142738195
-
The closing behavior of mechanical aortic heart valve prostheses
-
Lu P.C., Liu J.S., Huang R.H., Lo C.W., Lai H.C., and Hwang N.H.C. The closing behavior of mechanical aortic heart valve prostheses. ASAIO J 50 (2004) 294-300
-
(2004)
ASAIO J
, vol.50
, pp. 294-300
-
-
Lu, P.C.1
Liu, J.S.2
Huang, R.H.3
Lo, C.W.4
Lai, H.C.5
Hwang, N.H.C.6
-
16
-
-
0030152830
-
Identification of peak stresses in cardiac prostheses. A comparison of two-dimensional versus three-dimensional principal stress analyses
-
Fontaine A.A., Ellis J.T., Healy T.M., Hopmeyer J., and Yoganathan A.P. Identification of peak stresses in cardiac prostheses. A comparison of two-dimensional versus three-dimensional principal stress analyses. ASAIO J 42 (1996) 154-163
-
(1996)
ASAIO J
, vol.42
, pp. 154-163
-
-
Fontaine, A.A.1
Ellis, J.T.2
Healy, T.M.3
Hopmeyer, J.4
Yoganathan, A.P.5
-
17
-
-
0022383294
-
Pulsatile flow past St. Jude Medical bileaflet valve; an in vitro study
-
Chandran K.B. Pulsatile flow past St. Jude Medical bileaflet valve; an in vitro study. J Thorac Cardiovasc Surg 89 (1985) 743-749
-
(1985)
J Thorac Cardiovasc Surg
, vol.89
, pp. 743-749
-
-
Chandran, K.B.1
-
18
-
-
4344572152
-
New laboratory technique measures projected dynamic area of prosthetic heart valves
-
Scotten L.N., and Walker D.K. New laboratory technique measures projected dynamic area of prosthetic heart valves. J Heart Valve Dis 13 (2004) 120-133
-
(2004)
J Heart Valve Dis
, vol.13
, pp. 120-133
-
-
Scotten, L.N.1
Walker, D.K.2
-
19
-
-
0034287025
-
A two-dimensional fluid-structure interaction model of the aortic valve
-
De Hart J., Peters G.W.M., Schreus P.J.G., and Baaijens F.P.T. A two-dimensional fluid-structure interaction model of the aortic valve. J Biomech 33 (2000) 1079-1088
-
(2000)
J Biomech
, vol.33
, pp. 1079-1088
-
-
De Hart, J.1
Peters, G.W.M.2
Schreus, P.J.G.3
Baaijens, F.P.T.4
-
20
-
-
34748869580
-
PIV validation of blood-heart valve leaflet interaction modelling
-
Kaminsky R., Dumont K., Weber H.J., Schroll M., and Verdonck P. PIV validation of blood-heart valve leaflet interaction modelling. Int J Artif Organs 30 (2007) 640-648
-
(2007)
Int J Artif Organs
, vol.30
, pp. 640-648
-
-
Kaminsky, R.1
Dumont, K.2
Weber, H.J.3
Schroll, M.4
Verdonck, P.5
-
21
-
-
0023765723
-
Three-dimensional visualization of velocity fields downstream of six mechanical aortic valves in a pulsatile flow model
-
Hasenkam J.M., Giersiepen M., and Reul H. Three-dimensional visualization of velocity fields downstream of six mechanical aortic valves in a pulsatile flow model. J Biomech 21 (1988) 647-661
-
(1988)
J Biomech
, vol.21
, pp. 647-661
-
-
Hasenkam, J.M.1
Giersiepen, M.2
Reul, H.3
-
22
-
-
0022646878
-
Turbulent shear stress measurements in the vicinity of aortice heart valve prostheses
-
Yoganathan A.P., Woo Y.R., and Sung H.W. Turbulent shear stress measurements in the vicinity of aortice heart valve prostheses. J Biomech 19 (1986) 433-442
-
(1986)
J Biomech
, vol.19
, pp. 433-442
-
-
Yoganathan, A.P.1
Woo, Y.R.2
Sung, H.W.3
-
23
-
-
38349141343
-
Characterization of hemodynamic forces induced by mechanical heart valves: Reynolds vs. viscous stresses
-
Ge L., Dasi L.P., Sotiropulos F., and Yoganathan A.P. Characterization of hemodynamic forces induced by mechanical heart valves: Reynolds vs. viscous stresses. Ann Biomed Eng 36 (2008) 276-297
-
(2008)
Ann Biomed Eng
, vol.36
, pp. 276-297
-
-
Ge, L.1
Dasi, L.P.2
Sotiropulos, F.3
Yoganathan, A.P.4
-
24
-
-
36448990814
-
Flow visualization through two types of aortic prosthetic heart valves using stereoscopic high-speed particle image velocimetry
-
Kaminsky R., Kallweit S., Weber H.J., Claessens T., Jozwik K., and Verdonck P. Flow visualization through two types of aortic prosthetic heart valves using stereoscopic high-speed particle image velocimetry. Artif Organs 31 (2005) 869-879
-
(2005)
Artif Organs
, vol.31
, pp. 869-879
-
-
Kaminsky, R.1
Kallweit, S.2
Weber, H.J.3
Claessens, T.4
Jozwik, K.5
Verdonck, P.6
|