메뉴 건너뛰기




Volumn 50, Issue 12, 2009, Pages 3024-3034

Handling zone dividing method in packed bed liquid desiccant dehumidification/regeneration process

Author keywords

Air conditioning; Flow pattern; Heat and mass transfer; Liquid desiccant; Zone dividing

Indexed keywords

DEHUMIDIFICATION/REGENERATION; DESIGN AND OPTIMIZATION; FLOW CONFIGURATIONS; HEAT AND MASS TRANSFER; HEAT TRANSFER PROCESS; INLET AIR; KEY PROCESS; LIQUID DESICCANT; LIQUID DESICCANT AIR-CONDITIONING; MASS TRANSFER PERFORMANCE; MASS TRANSFER PROCESS; OPERATING CONDITION; PSYCHROMETRIC CHARTS; REGION ANALYSIS; RELATIVE POSITIONS; TWO-FLUID; ZONAL METHOD; ZONE DIVIDING;

EID: 70349437199     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2009.07.022     Document Type: Article
Times cited : (21)

References (17)
  • 1
    • 0032420645 scopus 로고    scopus 로고
    • Energy storage for desiccant cooling systems components development
    • Kessling W., Laevemann E., and Kapfhammer C. Energy storage for desiccant cooling systems components development. Sol Energy 64 4-6 (1998) 209-221
    • (1998) Sol Energy , vol.64 , Issue.4-6 , pp. 209-221
    • Kessling, W.1    Laevemann, E.2    Kapfhammer, C.3
  • 2
    • 0022713013 scopus 로고
    • Calculation of heat and mass transfer coefficients in a packed tower operating with a desiccant-air contact system
    • Gandhidasan P., Kettleborough C.F., and Ullah M.R. Calculation of heat and mass transfer coefficients in a packed tower operating with a desiccant-air contact system. J Sol Energy Eng 108 2 (1986) 123-128
    • (1986) J Sol Energy Eng , vol.108 , Issue.2 , pp. 123-128
    • Gandhidasan, P.1    Kettleborough, C.F.2    Ullah, M.R.3
  • 3
    • 0037052954 scopus 로고    scopus 로고
    • Study of an aqueous lithium chloride desiccant system: air dehumidification and desiccant regeneration
    • Fumo N., and Goswami D.Y. Study of an aqueous lithium chloride desiccant system: air dehumidification and desiccant regeneration. Sol Energy 72 4 (2002) 351-361
    • (2002) Sol Energy , vol.72 , Issue.4 , pp. 351-361
    • Fumo, N.1    Goswami, D.Y.2
  • 4
    • 0025529847 scopus 로고
    • Performance studies for an experimental solar open-cycle liquid desiccant air dehumidification system
    • Patnaik S., Lenz T.G., and Lof G.O.G. Performance studies for an experimental solar open-cycle liquid desiccant air dehumidification system. Sol Energy 44 3 (1990) 123-135
    • (1990) Sol Energy , vol.44 , Issue.3 , pp. 123-135
    • Patnaik, S.1    Lenz, T.G.2    Lof, G.O.G.3
  • 5
    • 33847020884 scopus 로고    scopus 로고
    • Experimental study on dehumidifier and regenerator of liquid desiccant cooling air conditioning system
    • Yin Y.G., Zhang X.S., and Chen Z.Q. Experimental study on dehumidifier and regenerator of liquid desiccant cooling air conditioning system. Build Environ 42 7 (2007) 2505-2511
    • (2007) Build Environ , vol.42 , Issue.7 , pp. 2505-2511
    • Yin, Y.G.1    Zhang, X.S.2    Chen, Z.Q.3
  • 6
    • 12344290325 scopus 로고    scopus 로고
    • Experimental investigation of a LiCl-water open absorption system for cooling and dehumidification
    • Gommed K., Grossman G., and Ziegler F. Experimental investigation of a LiCl-water open absorption system for cooling and dehumidification. J Sol Energy Eng 126 2 (2004) 710-715
    • (2004) J Sol Energy Eng , vol.126 , Issue.2 , pp. 710-715
    • Gommed, K.1    Grossman, G.2    Ziegler, F.3
  • 7
    • 33646418724 scopus 로고    scopus 로고
    • Experimental study on mass transfer performances of cross flow dehumidifier using liquid desiccant
    • Liu X.H., Zhang Y., Qu K.Y., and Jiang Y. Experimental study on mass transfer performances of cross flow dehumidifier using liquid desiccant. Energy Convers Manage 47 15-16 (2006) 2682-2692
    • (2006) Energy Convers Manage , vol.47 , Issue.15-16 , pp. 2682-2692
    • Liu, X.H.1    Zhang, Y.2    Qu, K.Y.3    Jiang, Y.4
  • 8
    • 33847397055 scopus 로고    scopus 로고
    • Experimental investigation of the heat and mass transfer between air and liquid desiccant in a cross flow regenerator
    • Liu X.H., Jiang Y., Chang X.M., and Yi X.Q. Experimental investigation of the heat and mass transfer between air and liquid desiccant in a cross flow regenerator. Renew Energy 32 10 (2007) 1623-1636
    • (2007) Renew Energy , vol.32 , Issue.10 , pp. 1623-1636
    • Liu, X.H.1    Jiang, Y.2    Chang, X.M.3    Yi, X.Q.4
  • 9
    • 0021531734 scopus 로고
    • Coefficients of heat and mass transfer in a packed bed suitable for solar regeneration of aqueous lithium chloride solutions
    • Lof G.O.G., Lenz T.G., and Rao S. Coefficients of heat and mass transfer in a packed bed suitable for solar regeneration of aqueous lithium chloride solutions. J Sol Energy Eng 106 4 (1984) 387-392
    • (1984) J Sol Energy Eng , vol.106 , Issue.4 , pp. 387-392
    • Lof, G.O.G.1    Lenz, T.G.2    Rao, S.3
  • 10
    • 0036604736 scopus 로고    scopus 로고
    • The effect of inlet parameters on the performance of packed tower regenerator
    • Sultan G.I., Hamed A.M., and Sultan A.A. The effect of inlet parameters on the performance of packed tower regenerator. Renew Energy 26 2 (2002) 271-283
    • (2002) Renew Energy , vol.26 , Issue.2 , pp. 271-283
    • Sultan, G.I.1    Hamed, A.M.2    Sultan, A.A.3
  • 11
    • 42749089240 scopus 로고    scopus 로고
    • Experimental study on the performance of regeneration of liquid desiccant air-conditioning system
    • in Chinese
    • Sun J., Shi M.H., and Zhao Y. Experimental study on the performance of regeneration of liquid desiccant air-conditioning system. J Eng Thermodyn 24 5 (2003) 867-869 in Chinese
    • (2003) J Eng Thermodyn , vol.24 , Issue.5 , pp. 867-869
    • Sun, J.1    Shi, M.H.2    Zhao, Y.3
  • 12
    • 0024936126 scopus 로고
    • An effectiveness model of liquid-desiccant system heat/mass exchangers
    • Stevens D.I., Braun J.E., and Klein S.A. An effectiveness model of liquid-desiccant system heat/mass exchangers. Sol energy 42 6 (1989) 449-455
    • (1989) Sol energy , vol.42 , Issue.6 , pp. 449-455
    • Stevens, D.I.1    Braun, J.E.2    Klein, S.A.3
  • 13
    • 0028501819 scopus 로고
    • Sensitivity analysis and component modeling of a packed-type liquid desiccant system at partial load operating-conditions
    • Khan A.Y. Sensitivity analysis and component modeling of a packed-type liquid desiccant system at partial load operating-conditions. Int J Energy Res 18 7 (1994) 643-655
    • (1994) Int J Energy Res , vol.18 , Issue.7 , pp. 643-655
    • Khan, A.Y.1
  • 14
    • 42749086525 scopus 로고    scopus 로고
    • Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant
    • Liu X.H., and Jiang Y. Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant. Energy Convers Manage 49 6 (2008) 1357-1366
    • (2008) Energy Convers Manage , vol.49 , Issue.6 , pp. 1357-1366
    • Liu, X.H.1    Jiang, Y.2
  • 15
    • 0033627555 scopus 로고    scopus 로고
    • Comparison between spray towers with and without fin coils for air dehumidification using triethylene glycol solutions and development of the mass-transfer correlations
    • Chung T.W., and Wu H. Comparison between spray towers with and without fin coils for air dehumidification using triethylene glycol solutions and development of the mass-transfer correlations. Ind Eng Chem Res 39 6 (2000) 2076-2084
    • (2000) Ind Eng Chem Res , vol.39 , Issue.6 , pp. 2076-2084
    • Chung, T.W.1    Wu, H.2
  • 17
    • 51649098103 scopus 로고    scopus 로고
    • Effect of regeneration mode on the performance of liquid desiccant packed bed regenerator
    • Liu X.H., Jiang Y., and Yi X.Q. Effect of regeneration mode on the performance of liquid desiccant packed bed regenerator. Renew Energy 34 1 (2009) 209-216
    • (2009) Renew Energy , vol.34 , Issue.1 , pp. 209-216
    • Liu, X.H.1    Jiang, Y.2    Yi, X.Q.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.