메뉴 건너뛰기




Volumn 4, Issue 3, 2009, Pages 160-165

Comparison of intubation success of video laryngoscopy versus direct laryngoscopy in the difficult airway using high-fidelity simulation

Author keywords

Difficult airway; GlideScope; Simulation; Video laryngoscopy

Indexed keywords

AIRWAY OBSTRUCTION; ARTICLE; CONTROLLED STUDY; ENDOTRACHEAL INTUBATION; LARYNGOSCOPY; OUTCOME ASSESSMENT; PRIORITY JOURNAL; SIMULATION; TONGUE EDEMA; VIDEORECORDING; VOCAL CORD;

EID: 70349337198     PISSN: 15592332     EISSN: 1559713X     Source Type: Journal    
DOI: 10.1097/SIH.0b013e318197d2e5     Document Type: Article
Times cited : (58)

References (25)
  • 1
    • 9244237622 scopus 로고    scopus 로고
    • Risk factors assessment of the difficult airway: An Italian survey of 1956 patients
    • Cattano D, Panicucci E, Paolicchi A, et al. Risk factors assessment of the difficult airway: an Italian survey of 1956 patients. Anesth Analg 2004;99:1774-1779.
    • (2004) Anesth Analg , vol.99
    • Cattano, D.1    Panicucci, E.2    Paolicchi, A.3
  • 3
    • 11444255353 scopus 로고    scopus 로고
    • The Glidescope® system: A clinical assessment of performance
    • DOI 10.1111/j.1365-2044.2004.04013.x
    • 3. Rai MR, Dering A, Verghese C. The Glidescope system: a clinical assessment of performance. Anaesthesia 2005;60:60-64. (Pubitemid 40081241)
    • (2005) Anaesthesia , vol.60 , Issue.1
    • Rai, M.R.1    Dering, A.2    Verghese, C.3
  • 4
    • 0038394393 scopus 로고    scopus 로고
    • Tracheal intubation using a Macintosh laryngoscope or a GlideScope® in 15 patients with cervical spine immobilization [4]
    • DOI 10.1093/bja/aeg560
    • 4. Argo F, Barzoi G, Montecchia F. Tracheal intubation using a Macintosh laryngoscope or Glidescope in 15 patients with cervical spine immobilization [Letter], Brit J Anaesth 2003;90:705-706. (Pubitemid 36592352)
    • (2003) British Journal of Anaesthesia , vol.90 , Issue.5
    • Agro, F.1    Barzoi, G.2    Montecchia, F.3
  • 6
    • 33646532277 scopus 로고    scopus 로고
    • An evaluation of the GlideScope®, a new video laryngoscope for difficult airways: A manikin study
    • Benjamin FJ, Boon D, French RA. An evaluation of the GlideScope®, a new video laryngoscope for difficult airways: a manikin study. Eur J Anaesthesiol 2006;23:517-521.
    • (2006) Eur J Anaesthesiol , vol.23
    • Benjamin, F.J.1    Boon, D.2    French, R.A.3
  • 7
    • 3042821019 scopus 로고    scopus 로고
    • Ease of intubation with the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways [6]
    • 7. Lim Y, Lim T, Liu EHC. Ease of intubation with the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways. Can J Anesth 2004;641-642. (Pubitemid 38867935)
    • (2004) Canadian Journal of Anesthesia , vol.51 , Issue.6
    • Lim, Y.1    Lim, T.-J.2    Liu, E.H.C.3
  • 9
    • 26944432273 scopus 로고    scopus 로고
    • Does a new videolaryngoscope (GlideScope) provide better glottic exposure?
    • Hsiao WT, Lin YH, Wu HS, Chen CL. Does a new videolaryngoscope (GlideScope) provide better glottic exposure? Acta Anaesthesiol Taiwan 2005;43:147-151.
    • (2005) Acta Anaesthesiol Taiwan , vol.43
    • Hsiao, W.T.1    Lin, Y.H.2    Wu, H.S.3    Chen, C.L.4
  • 11
    • 0036062653 scopus 로고    scopus 로고
    • Improving learning of a clinical skill: The first year's experience of teaching endotracheal intubation in a clinical simulation facility
    • DOI 10.1046/j.1365-2923.2002.01260.x
    • 11. Owen H, Plummer JL. Improving learning of a clinical skill: the first year's experience of teaching endotracheal intubation in a clinical simulation facility. Med Educ 2002;36:635-642. (Pubitemid 34779816)
    • (2002) Medical Education , vol.36 , Issue.7
    • Owen, H.1    Plummer, J.L.2
  • 12
    • 33750685639 scopus 로고    scopus 로고
    • The impact of experiential learning on NUS medical students: Our experience with task trainers and human patient simulation
    • Ti LK, Tan GM, Khoo SG, Chen FG. The impact of experiential learning on NUS medical students: our experience with task trainers and human patient simulation. Ann Acad Med Singapore 2006;35:619-623.
    • (2006) Ann Acad Med Singapore , vol.35
    • Ti, L.K.1    Tan, G.M.2    Khoo, S.G.3    Chen, F.G.4
  • 13
    • 23944495406 scopus 로고    scopus 로고
    • Human patient simulation is effective for teaching paramedic students endotracheal intubation
    • Hall RE, Plant JR, Bands CJ, et al. Human patient simulation is effective for teaching paramedic students endotracheal intubation. Acad Emerg Med 2005;12:850-855.
    • (2005) Acad Emerg Med , vol.12
    • Hall, R.E.1    Plant, J.R.2    Bands, C.J.3
  • 14
    • 70349355907 scopus 로고    scopus 로고
    • GlideScope™. website: Accessed January 10
    • GlideScope™. website: http://www.verathon.com/glidescope-index. htm. Accessed January 10, 2008.
    • (2008)
  • 15
    • 23844550249 scopus 로고    scopus 로고
    • Considerations aimed at facilitating the use of the new GlideScope®videolaryngoscope (letter)
    • author reply
    • Cuchillo JV, Rodriguez MA. Considerations aimed at facilitating the use of the new GlideScope®videolaryngoscope (letter). Can J Anesth 2005;52:661; author reply 661-662.
    • (2005) Can J Anesth , vol.52 , Issue.661
    • Cuchillo, J.V.1    Rodriguez, M.A.2
  • 16
    • 33846629539 scopus 로고    scopus 로고
    • Tracheal intubation using the GlideScope® with a combined curved pipe stylet, and endotracheal tube introducer [3]
    • 16. Muallem MK, Baraka A. Tracheal intubation using the GlideScope® with a combined curved pipe stylet, and endotracheal tube introducer [Letter]. Can J Anesth 2007;54:77-78. (Pubitemid 46178792)
    • (2007) Canadian Journal of Anesthesia , vol.54 , Issue.1
    • Muallem, M.1    Baraka, A.2
  • 18
    • 36749093518 scopus 로고    scopus 로고
    • The GlideScope® rigid stylet and malleable stylet are equally effective for GlideScope® use
    • Turkstra TP, Harle CC, Armstrong DP, et al. The GlideScope® rigid stylet and malleable stylet are equally effective for GlideScope® use. Can J Anesth 2007;54:891-896.
    • (2007) Can J Anesth , vol.54
    • Turkstra, T.P.1    Harle, C.C.2    Armstrong, D.P.3
  • 19
    • 13544263512 scopus 로고    scopus 로고
    • Evaluation of ease of intubation with the GlideScope® or Macintosh laryngoscope by anaesthetists in simulated easy and difficult laryngoscopy
    • DOI 10.1111/j.1365-2044.2004.04038.x
    • 19. Lim T, Lim Y, Liu E. Evaluation of ease of intubation with the GlideScope or Macintosh laryngoscope by anaesthetists in simulated easy and difficult laryngoscopy. Anaesthesia 2005;60:180-183. (Pubitemid 40220687)
    • (2005) Anaesthesia , vol.60 , Issue.2
    • Lim, T.J.1    Lim, Y.2    Liu, E.H.C.3
  • 20
    • 17144365474 scopus 로고    scopus 로고
    • A comparison of the GlideScope® with the Macintosh laryngoscope for tracheal intubation in patients with simulated difficult airway
    • 20. Lim Y, Yeo S. A comparison of the Glidescope with the Macintosh laryngoscope for tracheal intubation in patients with simulated difficult airway. Anaesth Intensive Care 2005;33:243-247. (Pubitemid 40521027)
    • (2005) Anaesthesia and Intensive Care , vol.33 , Issue.2
    • Lim, Y.1    Yeo, S.W.2
  • 21
    • 0035148497 scopus 로고    scopus 로고
    • Training with video imaging improves the initial intubation success rates of paramedic trainees in an operating room setting
    • DOI 10.1067/mem.2001.111516
    • 21. Levitan RM, Goldman TS, Brya DA, Shofer F, Herlich A. Training with video imaging improves the initial intubation success rates of paramedic trainees in an operating room setting. Ann Emerg Med 2001;37:46-50. (Pubitemid 32066339)
    • (2001) Annals of Emergency Medicine , vol.37 , Issue.1
    • Levitan, R.M.1    Goldman, T.S.2    Bryan, D.A.3    Shofer, F.4    Herlich, A.5
  • 22
    • 70349357631 scopus 로고    scopus 로고
    • McGrath™. Accessed January 10, 2008
    • McGrath™. Video Laryngoscope website: http://www.aircraftmedical. com. Accessed January 10, 2008.
  • 24
    • 38449095575 scopus 로고    scopus 로고
    • Use of the McGrath® videolaryngoscope in the management of difficult and failed tracheal intubation
    • DOI 10.1093/bja/aem303
    • 24. Shippey B, Ray D, McKeown D. Use of the McGrath videolaryngoscope in the management of difficult and failed tracheal intubation. Br J Anaesth 2008;100:116-119. (Pubitemid 351773410)
    • (2008) British Journal of Anaesthesia , vol.100 , Issue.1
    • Shippey, B.1    Ray, D.2    McKeown, D.3
  • 25
    • 34249798746 scopus 로고    scopus 로고
    • Case series: The McGrath® videolaryngoscope - An initial clinical evaluation
    • 25. Shippey B, Ray D, McKeown D. Case series: the McGrath videolaryngoscope-an initial clinical evaluation. Can J Anaesth 2007; 54:307-313. (Pubitemid 46851236)
    • (2007) Canadian Journal of Anesthesia , vol.54 , Issue.4
    • Shippey, B.1    Ray, D.2    McKeown, D.3