메뉴 건너뛰기




Volumn 30, Issue 10, 2009, Pages 3361-3377

Simultaneously recorded EEG-fMRI: Removal of gradient artifacts by subtraction of head movement related average artifact waveforms

Author keywords

Gradient artifact; Head movement; Resampling; Simultaneous EEG fMRI

Indexed keywords

ARTICLE; ARTIFACT REDUCTION; ELECTROENCEPHALOGRAPHY; FREQUENCY MODULATION; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HEAD MOVEMENT; HEAD POSITION; IMAGE ANALYSIS; IMAGE ENHANCEMENT; IMAGE QUALITY; NOISE REDUCTION; OPTICAL RESOLUTION; PHANTOM; PRIORITY JOURNAL; REPRODUCIBILITY; WAVEFORM;

EID: 70349336902     PISSN: 10659471     EISSN: None     Source Type: Journal    
DOI: 10.1002/hbm.20758     Document Type: Article
Times cited : (21)

References (26)
  • 1
    • 0033870442 scopus 로고    scopus 로고
    • A method for removing imaging artifact from continuous EEG recorded during functional MRI
    • DOI 10.1006/nimg.2000.0599
    • Allen PJ, Josephs O, Turner R (2000): A method for removing imaging artifact from continuous EEG recorded during functional MRI. NeuroImage 12:230-239. (Pubitemid 30627023)
    • (2000) NeuroImage , vol.12 , Issue.2 , pp. 230-239
    • Allen, P.J.1    Josephs, O.2    Turner, R.3
  • 2
    • 27744579731 scopus 로고    scopus 로고
    • Visual evoked potentials recovered from fMRI scan periods
    • DOI 10.1002/hbm.20152
    • Becker R, Ritter P, Moosmann M, Villringer A (2005): Visual evoked potentials recovered from fMRI scan periods. Hum Brain Mapp 26:221-230. (Pubitemid 41598320)
    • (2005) Human Brain Mapping , vol.26 , Issue.3 , pp. 221-230
    • Becker, R.1    Ritter, P.2    Moosmann, M.3    Villringer, A.4
  • 4
    • 34547831040 scopus 로고    scopus 로고
    • Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: Removal of the ballistocardiogram artefact
    • DOI 10.1016/j.neuroimage.2006.09.031, PII S1053811906009827
    • Debener S, Strobel A, Sorger B, Peters J, Kranczioch C, Engel AK, Goebel R (2007): Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: Removal of the ballistocardiogram artefact. Neuroimage 34:587-597. (Pubitemid 44827764)
    • (2007) NeuroImage , vol.34 , Issue.2 , pp. 587-597
    • Debener, S.1    Strobel, A.2    Sorger, B.3    Peters, J.4    Kranczioch, C.5    Engel, A.K.6    Goebel, R.7
  • 6
    • 0033794032 scopus 로고    scopus 로고
    • Acquiring simultaneous EEG and functional MRI
    • DOI 10.1016/S1388-2457(00)00456-9, PII S1388245700004569
    • Goldman RI, Stern JM, Engel J, Cohen MS (2000): Acquiring simultaneous EEG and functional MRI. Clin Neurophysiol 111:1974-1980. (Pubitemid 30799282)
    • (2000) Clinical Neurophysiology , vol.111 , Issue.11 , pp. 1974-1980
    • Goldman, R.I.1    Stern, J.M.2    Engel Jr., J.3    Cohen, M.S.4
  • 9
    • 39449135873 scopus 로고    scopus 로고
    • Simultaneous recording of EEG and BOLD responses: A historical perspective
    • Herrmann CS, Debener S (2008): Simultaneous recording of EEG and BOLD responses: A historical perspective. Int J Psychophysiol 67:161-168.
    • (2008) Int J Psychophysiol , vol.67 , pp. 161-168
    • Herrmann, C.S.1    Debener, S.2
  • 10
    • 0033762044 scopus 로고    scopus 로고
    • Electroencephalography during functional echo-planar imaging: Detection of epileptic spikes using post-processing methods
    • Hoffmann A, Jäger L, Warhahn KJ, Jaschke M, Noachtar S, Reiser M (2000): Electroencephalography during functional echo-planar imaging: Detection of epileptic spikes using post-processing methods. Magn Reson Med 44:791-798.
    • (2000) Magn Reson Med , vol.44 , pp. 791-798
    • Hoffmann, A.1    Jäger, L.2    Warhahn, K.J.3    Jaschke, M.4    Noachtar, S.5    Reiser, M.6
  • 13
    • 0033867418 scopus 로고    scopus 로고
    • Recording of the event-related potentials during functional MRI at 3.0 tesla field strength
    • DOI 10.1002/1522-2594(200008)44:2<277::AID-MRM15>3.0.CO;2-X
    • Kruggel F, Wiggins CJ, Herrmann CS, von Cramon DY (2000): Recording of the event-related potentials during functional MRI at 3.0 Tesla field strength. Magn Reson Med 44:277-282. (Pubitemid 30614787)
    • (2000) Magnetic Resonance in Medicine , vol.44 , Issue.2 , pp. 277-282
    • Kruggel, F.1    Wiggins, C.J.2    Herrmann, C.S.3    Von Cramon, D.Y.4
  • 15
    • 0034878326 scopus 로고    scopus 로고
    • Event-related fMRI with simultaneous and continuous EEG: Description of the method and initial case report
    • DOI 10.1006/nimg.2001.0853
    • Lemieux L, Salek-Haddadi A, Josephs O, Allen P, Toms N, Scott C, Krakow K, Turner R, Fish DR (2001): Event-related fMRI with simultaneous and continuous EEG: Description of the method and initial case report. NeuroImage 14:780-787. (Pubitemid 32801724)
    • (2001) NeuroImage , vol.14 , Issue.3 , pp. 780-787
    • Lemieux, L.1    Salek-Haddadi, A.2    Josephs, O.3    Allen, P.4    Toms, N.5    Scott, C.6    Krakow, K.7    Turner, R.8    Fish, D.R.9
  • 16
    • 33747804274 scopus 로고    scopus 로고
    • Synchronization facilitates removal of MRI artefacts from concurrent EEG recordings and increases usable bandwidth
    • DOI 10.1016/j.neuroimage.2006.04.231, PII S1053811906005428
    • Mandelkow H, Halder P, Boesiger P, Breandeis D (2006): Synchronization facilitates removal of MRI artifacts from concurrent EEG recordings and increases usable bandwidth. NeuroImage 32:1120-1126. (Pubitemid 44278682)
    • (2006) NeuroImage , vol.32 , Issue.3 , pp. 1120-1126
    • Mandelkow, H.1    Halder, P.2    Boesiger, P.3    Brandeis, D.4
  • 17
    • 35148821509 scopus 로고    scopus 로고
    • Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis
    • DOI 10.1016/j.neuroimage.2006.09.037, PII S1053811906009761
    • Mantini D, Perrucci MG, Cugini S, Ferretti A, Romani GL, Del Gratta C (2007): Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis. Neuroimage 34:598-607. (Pubitemid 44827763)
    • (2007) NeuroImage , vol.34 , Issue.2 , pp. 598-607
    • Mantini, D.1    Perrucci, M.G.2    Cugini, S.3    Ferretti, A.4    Romani, G.L.5    Del Gratta, C.6
  • 18
    • 3843102642 scopus 로고    scopus 로고
    • Removal of time-varying gradient artifacts from EEG data acquired during continuous fMRI
    • DOI 10.1016/j.clinph.2004.04.005, PII S1388245704001476
    • Negishi M, Abildgaard M, Nixon T, Constable RT (2004): Removal of time-varying gradient artifacts from EEG data acquired during continuous fMRI. Clin Neurophysiol 115:2181-2192. (Pubitemid 39037308)
    • (2004) Clinical Neurophysiology , vol.115 , Issue.9 , pp. 2181-2192
    • Negishi, M.1    Abildgaard, M.2    Nixon, T.3    Todd Constable, R.4
  • 19
    • 27544446124 scopus 로고    scopus 로고
    • Removal of FMRI environment artifacts from EEG data using optimal basis sets
    • Niazy RK, Beckmann CF, Iannetti GD, Brady JM, Smith SM (2005): Removal of FMRI environment artifacts from EEG data using optimal basis sets. Neuroimage 28:720-737.
    • (2005) Neuroimage , vol.28 , pp. 720-737
    • Niazy, R.K.1    Beckmann, C.F.2    Iannetti, G.D.3    Brady, J.M.4    Smith, S.M.5
  • 22
    • 0033772320 scopus 로고    scopus 로고
    • Reduction of ECG and gradient related artifacts in simultaneously recorded human EEG/MRI data
    • DOI 10.1016/S0730-725X(00)00178-8, PII S0730725X00001788
    • Sijbers J, Van Audekerke J, Verhoye M, Van der Linden A, Van Dyck D (2000): Reduction of ECG and gradient related artifacts in simultaneously recorded human EEG/MRI data. Magn Reson Imaging 18:881-886. (Pubitemid 30769068)
    • (2000) Magnetic Resonance Imaging , vol.18 , Issue.7 , pp. 881-886
    • Sijbersa, J.1    Van Audekerke, J.2    Verhoye, M.3    Van Der Linden, A.4    Van Dyck, D.5
  • 24
    • 0035878735 scopus 로고    scopus 로고
    • Removal of ECG interference from the EEG recordings in small animals using independent component analysis
    • DOI 10.1016/S0165-0270(01)00366-1, PII S0165027001003661
    • Tong S, Bezerianos A, Paul J, Zhu Y, Thakor N (2001): Removal of ECG interference from the EEG recordings in small animals using independent component analysis. J Neurosci Methods 108:11-17. (Pubitemid 32664037)
    • (2001) Journal of Neuroscience Methods , vol.108 , Issue.1 , pp. 11-17
    • Tong, S.1    Bezerianos, A.2    Paul, J.3    Zhu, Y.4    Thakor, N.5
  • 25
    • 33644764153 scopus 로고    scopus 로고
    • Artifact reduction for simultaneous EEG/fMRI recording: Adaptive FIR reduction of imaging artifacts
    • DOI 10.1016/j.clinph.2005.07.025, PII S1388245705005043
    • Wan X, Iwata K, Riera J, Kitamura M, Kawashima R (2006): Artifact reduction for simultaneous EEG/fMRI recording: Adaptive FIR reduction of imaging artifacts. Clin Neurophysiol 117:681-692. (Pubitemid 43344001)
    • (2006) Clinical Neurophysiology , vol.117 , Issue.3 , pp. 681-692
    • Wan, X.1    Iwata, K.2    Riera, J.3    Kitamura, M.4    Kawashima, R.5
  • 26
    • 84908144695 scopus 로고
    • The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms
    • Welch PD (1967): The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms. IEEE Trans Audio Electroac AU 15:70-73.
    • (1967) IEEE Trans Audio Electroac AU , vol.15 , pp. 70-73
    • Welch, P.D.1