메뉴 건너뛰기




Volumn 23, Issue 7, 2009, Pages 627-638

Evaluation of dynamic row-action maximum likelihood algorithm reconstruction for quantitative 15O brain PET

Author keywords

15O PET; CBF; Dynamic RAMLA; Iterative reconstruction; Oxygen metabolism

Indexed keywords

OXYGEN 15;

EID: 70349321158     PISSN: 09147187     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12149-009-0280-2     Document Type: Article
Times cited : (11)

References (31)
  • 2
    • 0021355477 scopus 로고
    • Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography
    • MA Mintun ME Raichle WR Martin P Herscovitch 1984 Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography J Nucl Med 25 177 187
    • (1984) J Nucl Med , vol.25 , pp. 177-187
    • Mintun, M.A.1    Raichle, M.E.2    Martin, W.R.3    Herscovitch, P.4
  • 5
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • LA Shepp Y Vardi 1982 Maximum likelihood reconstruction for emission tomography IEEE Trans Med Imaging 1 113 122
    • (1982) IEEE Trans Med Imaging , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 6
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • HM Hudson RS Larkin 1994 Accelerated image reconstruction using ordered subsets of projection data IEEE Trans Med Imaging 13 601 609
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 7
    • 0030270511 scopus 로고    scopus 로고
    • A row-action alternative to the em algorithm for maximizing likelihood in emission tomography
    • J Browne AB de Pierro 1996 A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography IEEE Trans Med Imaging 15 687 699
    • (1996) IEEE Trans Med Imaging , vol.15 , pp. 687-699
    • Browne, J.1    De Pierro, A.B.2
  • 8
    • 0038458982 scopus 로고    scopus 로고
    • Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography
    • E Tanaka H Kudo 2003 Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography Phys Med Biol 48 1405 1422
    • (2003) Phys Med Biol , vol.48 , pp. 1405-1422
    • Tanaka, E.1    Kudo, H.2
  • 9
    • 0037150011 scopus 로고    scopus 로고
    • A non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images
    • I Buvat 2002 A non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images Phys Med Biol 47 1761 1775
    • (2002) Phys Med Biol , vol.47 , pp. 1761-1775
    • Buvat, I.1
  • 10
    • 34247242955 scopus 로고    scopus 로고
    • Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 Standard
    • K Matsumoto K Kitamura T Mizuta K Tanaka S Yamamoto S Sakamoto 2006 Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 Standard J Nucl Med 47 83 90
    • (2006) J Nucl Med , vol.47 , pp. 83-90
    • Matsumoto, K.1    Kitamura, K.2    Mizuta, T.3    Tanaka, K.4    Yamamoto, S.5    Sakamoto, S.6
  • 11
    • 0028926692 scopus 로고
    • Regional cerebral blood flow, blood volume, oxygen extraction fraction, and oxygen utilization rate in normal volunteers measured by the autoradiographic technique and the single breath inhalation method
    • J Hatazawa H Fujita I Kanno T Satoh H Iida S Miura 1995 Regional cerebral blood flow, blood volume, oxygen extraction fraction, and oxygen utilization rate in normal volunteers measured by the autoradiographic technique and the single breath inhalation method Ann Nucl Med 9 15 21
    • (1995) Ann Nucl Med , vol.9 , pp. 15-21
    • Hatazawa, J.1    Fujita, H.2    Kanno, I.3    Satoh, T.4    Iida, H.5    Miura, S.6
  • 13
    • 0018384498 scopus 로고
    • Validation of tomographic measurement of cerebral blood volume with C-11-labeled carboxyhemoglobin
    • ME Phelps SC Huang EJ Hoffman DE Kuhl 1979 Validation of tomographic measurement of cerebral blood volume with C-11-labeled carboxyhemoglobin J Nucl Med 20 328 334
    • (1979) J Nucl Med , vol.20 , pp. 328-334
    • Phelps, M.E.1    Huang, S.C.2    Hoffman, E.J.3    Kuhl, D.E.4
  • 16
    • 0031713525 scopus 로고    scopus 로고
    • Noninvasive quantitation of cerebral blood flow using oxygen-15-water and a dual-PET system
    • H Iida S Miura Y Shoji T Ogawa H Kado Y Narita 1998 Noninvasive quantitation of cerebral blood flow using oxygen-15-water and a dual-PET system J Nucl Med 39 1789 1798
    • (1998) J Nucl Med , vol.39 , pp. 1789-1798
    • Iida, H.1    Miura, S.2    Shoji, Y.3    Ogawa, T.4    Kado, H.5    Narita, Y.6
  • 18
    • 0027317388 scopus 로고
    • Modeling approach to eliminate the need to separate arterial plasma in oxygen-15 inhalation positron emission tomography
    • H Iida T Jones S Miura 1993 Modeling approach to eliminate the need to separate arterial plasma in oxygen-15 inhalation positron emission tomography J Nucl Med 34 1333 1340
    • (1993) J Nucl Med , vol.34 , pp. 1333-1340
    • Iida, H.1    Jones, T.2    Miura, S.3
  • 20
    • 0037035403 scopus 로고    scopus 로고
    • A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences: Implementation on the ECAT EXACT HR+
    • NC Ferreira R Trebossen C Lartizien V Brulon P Merceron B Bendriem 2002 A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences: implementation on the ECAT EXACT HR+ Phys Med Biol 47 1555 1571
    • (2002) Phys Med Biol , vol.47 , pp. 1555-1571
    • Ferreira, N.C.1    Trebossen, R.2    Lartizien, C.3    Brulon, V.4    Merceron, P.5    Bendriem, B.6
  • 21
    • 70349342245 scopus 로고    scopus 로고
    • The Institute of Electrical and Electronics Engineers Inc. (IEEE) San Juan
    • Ishikawa A, Kitamura K, Mizuta T, Tanaka K, Amano M, Inoue Y, et al. Implementation of on-the-fly scatter correction using dual-energy window method in continuous 3D whole body PET scanning. IEEE nuclear science symposium and medical imaging conference. San Juan: The Institute of Electrical and Electronics Engineers Inc. (IEEE); 2005. p. 11-138.
    • (2005) , pp. 11-138
    • Ishikawa, A.1    Kitamura, K.2    Mizuta, T.3    Tanaka, K.4    Amano, M.5    Inoue, Y.6
  • 22
    • 0032970425 scopus 로고    scopus 로고
    • Nonlinear spatial normalization using basis functions
    • J Ashburner KJ Friston 1999 Nonlinear spatial normalization using basis functions Hum Brain Mapp 7 254 266
    • (1999) Hum Brain Mapp , vol.7 , pp. 254-266
    • Ashburner, J.1    Friston, K.J.2
  • 23
    • 33645070196 scopus 로고    scopus 로고
    • Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 labeled water PET and voxel-based morphometry
    • H Ito K Inoue R Goto S Kinomura Y Taki K Okada 2006 Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 labeled water PET and voxel-based morphometry Ann Nucl Med 20 131 138
    • (2006) Ann Nucl Med , vol.20 , pp. 131-138
    • Ito, H.1    Inoue, K.2    Goto, R.3    Kinomura, S.4    Taki, Y.5    Okada, K.6
  • 24
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • JM Bland DG Altman 1986 Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 307 310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 25
    • 0035000317 scopus 로고    scopus 로고
    • Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: Quantitative characteristics and effects on kinetic modeling
    • R Boellaard A van Lingen AA Lammertsma 2001 Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling J Nucl Med 42 808 817
    • (2001) J Nucl Med , vol.42 , pp. 808-817
    • Boellaard, R.1    Van Lingen, A.2    Lammertsma, A.A.3
  • 27
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratios using noise equivalents counts
    • SC Strother ME Casey EJ Hoffman 1990 Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratios using noise equivalents counts IEEE Trans Nucl Sci 37 783 788
    • (1990) IEEE Trans Nucl Sci , vol.37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 30
    • 0041737549 scopus 로고    scopus 로고
    • Estimation of the local statistical noise in positron emission tomography revisited: Practical implementation
    • LD Nickerson S Narayana JL Lancaster PT Fox JH Gao 2003 Estimation of the local statistical noise in positron emission tomography revisited: practical implementation Neuroimage 19 442 456
    • (2003) Neuroimage , vol.19 , pp. 442-456
    • Nickerson, L.D.1    Narayana, S.2    Lancaster, J.L.3    Fox, P.T.4    Gao, J.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.