메뉴 건너뛰기




Volumn 8, Issue 3, 2009, Pages 156-165

High-power, computer-controlled, light-emitting diode- based light sources for fluorescence imaging and image- guided surgery

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL MODEL; EMBEDDED PROCESSORS; FIELD OF VIEWS; FLUENCE RATES; FLUORESCENCE EXCITATION; FLUORESCENCE IMAGING; GUIDED SURGERY; HEAT DISSIPATION; HIGH-POWER; IMAGE GUIDED SURGERY; MULTIMODULE; NEAR-INFRARED FLUORESCENCE; OPERATING TEMPERATURE; OPTICAL IMAGING; PRECISE CONTROL; TEMPERATURE MONITORING; TIME TEMPERATURE; WHITE LIGHT; WORKING DISTANCES;

EID: 70349287716     PISSN: 15353508     EISSN: None     Source Type: Journal    
DOI: 10.2310/7290.2009.00009     Document Type: Article
Times cited : (54)

References (13)
  • 1
    • 34447527023 scopus 로고    scopus 로고
    • Molecular imaging using visible light to reveal biological changes in the brain
    • ix
    • Contag CH. Molecular imaging using visible light to reveal biological changes in the brain. Neuroimaging Clin N Am 2006;16: 633-54, ix.
    • (2006) Neuroimaging Clin N Am , vol.16 , pp. 633-654
    • Contag, C.H.1
  • 2
    • 0142230995 scopus 로고    scopus 로고
    • In vivo near-infrared fluorescence imaging
    • Frangioni JV. In vivo near-infrared fluorescence imaging. Curr Opin Chem Biol 2003;7:626-634
    • (2003) Curr Opin Chem Biol , vol.7 , pp. 626-634
    • Frangioni, J.V.1
  • 3
    • 42149142416 scopus 로고    scopus 로고
    • A low-cost, linear, DC - 35 MHz, high-power LED driver for continuous wave (CW) and fluorescence lifetime imaging (FLIM)
    • Gioux S, Kianzad V, Ciocan R, et al. A low-cost, linear, DC - 35 MHz, high-power LED driver for continuous wave (CW) and fluorescence lifetime imaging (FLIM). Proc SPIE 2008;6848: 684807-684811
    • (2008) Proc SPIE , vol.6848 , pp. 684807-684811
    • Gioux, S.1    Kianzad, V.2    Ciocan, R.3
  • 4
    • 33845675782 scopus 로고    scopus 로고
    • Image-guided oncologic surgery using invisible light: Completed pre-clinical development for sentinel lymph node mapping
    • Tanaka E, Choi HS, Fujii H, et al. Image-guided oncologic surgery using invisible light: completed pre-clinical development for sentinel lymph node mapping. Ann Surg Oncol 2006;13: 1671-1681
    • (2006) Ann Surg Oncol , vol.13 , pp. 1671-1681
    • Tanaka, E.1    Choi, H.S.2    Fujii, H.3
  • 5
    • 0036126627 scopus 로고    scopus 로고
    • Trimodal spectro- scopy for the detection and characterization of cervical precancers in vivo
    • Georgakoudi I, Sheets EE, Muller MG, et al. Trimodal spectro- scopy for the detection and characterization of cervical precancers in vivo. Am J Obstet Gynecol 2002;186:374-382
    • (2002) Am J Obstet Gynecol , vol.186 , pp. 374-382
    • Georgakoudi, I.1    Sheets, E.E.2    Muller, M.G.3
  • 6
    • 10144247263 scopus 로고    scopus 로고
    • A clinical study of optical biopsy of the uterine cervix using a multispectral imaging system
    • Orfanoudaki IM, Themelis GC, Sifakis SK, et al. A clinical study of optical biopsy of the uterine cervix using a multispectral imaging system. Gynecol Oncol 2005;96:119-131
    • (2005) Gynecol Oncol , vol.96 , pp. 119-131
    • Orfanoudaki, I.M.1    Themelis, G.C.2    Sifakis, S.K.3
  • 7
    • 2542497639 scopus 로고    scopus 로고
    • Optical detection of high-grade cervical intraepithelial neoplasia in vivo: Results of a 604-patient study
    • Huh WK, Cestero RM, Garcia FA, et al. Optical detection of high-grade cervical intraepithelial neoplasia in vivo: results of a 604-patient study. Am J Obstet Gynecol 2004;190:1249-1257
    • (2004) Am J Obstet Gynecol , vol.190 , pp. 1249-1257
    • Huh, W.K.1    Cestero, R.M.2    Garcia, F.A.3
  • 8
    • 20544477014 scopus 로고    scopus 로고
    • An innovative portable instrument for dermoscopy without the need of immersion fluids
    • Arrazola P, Mullani NA, Abramovits W. DermLite II: an innovative portable instrument for dermoscopy without the need of immersion fluids. Skinmed 2005;4:78-83.
    • (2005) Skinmed , vol.4 , pp. 78-83
    • Arrazola, P.1    Mullani, N.A.2    Abramovits, W.3    Dermlite, I.I.4
  • 9
    • 20444497637 scopus 로고    scopus 로고
    • Modulated imaging: Quantitative analysis and tomography of turbid media in the spatial-frequency domain
    • Cuccia DJ, Bevilacqua F, Durkin AJ, Tromberg BJ. Modulated imaging: quantitative analysis and tomography of turbid media in the spatial-frequency domain. Opt Lett 2005;30:1354-1356
    • (2005) Opt Lett , vol.30 , pp. 1354-1356
    • Cuccia, D.J.1    Bevilacqua, F.2    Durkin, A.J.3    Tromberg, B.J.4
  • 11
    • 40949113163 scopus 로고    scopus 로고
    • Imaging of lymph flow in breast cancer patients after microdose administration of a near-infrared fluorophore: Feasibility study
    • Sevick-Muraca EM, Sharma R, Rasmussen JC, et al. Imaging of lymph flow in breast cancer patients after microdose administration of a near-infrared fluorophore: feasibility study. Radiology 2008;46:734-741
    • (2008) Radiology , vol.46 , pp. 734-741
    • Sevick-Muraca, E.M.1    Sharma, R.2    Rasmussen, J.C.3
  • 12
    • 11144283639 scopus 로고    scopus 로고
    • Enhanced fluorescence emission using a programmable, reconfigurable LED-array based light source
    • Moe A, Banani N, Lee L, et al. Enhanced fluorescence emission using a programmable, reconfigurable LED-array based light source. Conf Proc IEEE Eng Med Biol Soc 2004;3:2090-2093
    • (2004) Conf Proc IEEE Eng Med Biol Soc , vol.3 , pp. 2090-2093
    • Moe, A.1    Banani, N.2    Lee, L.3
  • 13
    • 11144302080 scopus 로고    scopus 로고
    • SLAP: Design software for optimization of fluorescence analysis systems
    • Banani N, Lee LA, Holl MR, et al. SLAP: design software for optimization of fluorescence analysis systems. Conf Proc IEEE Eng Med Biol Soc 2004;3:2086-2089
    • (2004) Conf Proc IEEE Eng Med Biol Soc , vol.3 , pp. 2086-2089
    • Banani, N.1    Lee, L.A.2    Holl, M.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.