메뉴 건너뛰기




Volumn , Issue , 2009, Pages

Use vibration monitoring to identify circuit breakers for condition assessment

Author keywords

Asset management; Circuit breaker; Condition assessment; Fault analysis; Vibration monitoring

Indexed keywords

CIRCUIT BREAKER; CONDITION ASSESSMENT; CONDITION ASSESSMENTS; DATA PROCESSING ALGORITHMS; FAULT ANALYSIS; FAULTY CIRCUITS; SENSOR SELECTION; TEST RESULTS; VIBRATION MONITORING;

EID: 70349279219     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PSCE.2009.4839936     Document Type: Conference Paper
Times cited : (5)

References (17)
  • 3
    • 23644444791 scopus 로고    scopus 로고
    • Application of Numeric Protectice Relay Circuit Breaker Duty Monitoring
    • July/Aug
    • G. Dalke, J. Horak, "Application of Numeric Protectice Relay Circuit Breaker Duty Monitoring", IEEE Trans. On Industry Applications, 41(4), pp.1118-1124, July/Aug 2005
    • (2005) IEEE Trans. On Industry Applications , vol.41 , Issue.4 , pp. 1118-1124
    • Dalke, G.1    Horak, J.2
  • 6
    • 66349111691 scopus 로고    scopus 로고
    • Design of trip current monitoring system for circuit breaker condition assessment, IET Generation
    • Jan
    • B. Stephen, S.M. Strachan, S.D.J. McArthur, J.R. McDonald, K. Hamilton, "Design of trip current monitoring system for circuit breaker condition assessment", IET Generation, Transmission & Distribution, 1(1), pp.89-95, Jan 2007
    • (2007) Transmission & Distribution , vol.1 , Issue.1 , pp. 89-95
    • Stephen, B.1    Strachan, S.M.2    McArthur, S.D.J.3    McDonald, J.R.4    Hamilton, K.5
  • 7
    • 34147152235 scopus 로고    scopus 로고
    • Providing decision support for the condition-based maintenance of circuit breakers through data mining of trip coil current signatures
    • Jan
    • S.M. Strachan, S.D.J. McArthur, B. Stephen, J.R. McDonald, A. Campbell, "Providing decision support for the condition-based maintenance of circuit breakers through data mining of trip coil current signatures", IEEE Trans. On Power Delivery, 22(1), pp. 178-186, Jan 2007
    • (2007) IEEE Trans. On Power Delivery , vol.22 , Issue.1 , pp. 178-186
    • Strachan, S.M.1    McArthur, S.D.J.2    Stephen, B.3    McDonald, J.R.4    Campbell, A.5
  • 12
    • 0030360226 scopus 로고    scopus 로고
    • Circuit breaker condition assessment by vibration and trip coil analysis
    • Digest, 186, Dec
    • S. Beattie, "Circuit breaker condition assessment by vibration and trip coil analysis", IEE Colloquium on Monitors and Condition Assessment Equipment (Digest No. 1996/186), Dec.1996
    • (1996) IEE Colloquium on Monitors and Condition Assessment Equipment , Issue.1996
    • Beattie, S.1
  • 14
    • 0030262878 scopus 로고    scopus 로고
    • Vibration analysis for diagnostic testing of circuit breakers
    • Oct
    • M. Runde, G.E. Ottesen, B. Skyberg, M. Ohlen, "Vibration analysis for diagnostic testing of circuit breakers", IEEE Trans. On Power Delivery, 11(4), pp. 1816-1823, Oct 1996
    • (1996) IEEE Trans. On Power Delivery , vol.11 , Issue.4 , pp. 1816-1823
    • Runde, M.1    Ottesen, G.E.2    Skyberg, B.3    Ohlen, M.4
  • 15
    • 27844523663 scopus 로고    scopus 로고
    • Continuous Monitoring of Circuit Breakers using Vibration Analysis
    • Oct
    • H.K. Hoidalen, M. Runde, "Continuous Monitoring of Circuit Breakers using Vibration Analysis", IEEE Trans. On Power Delivery, 20(4), pp. 2458-2465, Oct 2005
    • (2005) IEEE Trans. On Power Delivery , vol.20 , Issue.4 , pp. 2458-2465
    • Hoidalen, H.K.1    Runde, M.2
  • 17
    • 33645747793 scopus 로고    scopus 로고
    • The detection of the closing moments of a vacuum circuit breaker by vibration analysis
    • Apr
    • Y. Meng, S. Jia, Z. Shi, M. Rong, "The detection of the closing moments of a vacuum circuit breaker by vibration analysis", IEEE Trans. On Power Delivery, 21(2), pp. 652-658, Apr 2006
    • (2006) IEEE Trans. On Power Delivery , vol.21 , Issue.2 , pp. 652-658
    • Meng, Y.1    Jia, S.2    Shi, Z.3    Rong, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.