메뉴 건너뛰기




Volumn 17, Issue 3, 2009, Pages 107-110

Primary prevention with the ICD in clinical practice: Not as straightforward as the guidelines suggest?

Author keywords

Aged; Defibrillators; Implantable; Review; Risk assessment

Indexed keywords

CARDIOVASCULAR RISK; CLINICAL PRACTICE; DEFIBRILLATOR; DEVICE THERAPY; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE FAILURE; HUMAN; IMPLANTATION; LONGEVITY; MEDICAL DECISION MAKING; PATIENT SELECTION; PRACTICE GUIDELINE; PRIMARY PREVENTION; REVIEW; SUDDEN DEATH; SURVIVAL RATE;

EID: 70349278518     PISSN: 15685888     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03086228     Document Type: Review
Times cited : (7)

References (41)
  • 1
    • 70349288617 scopus 로고    scopus 로고
    • ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: Executive Summary. A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines
    • Epstein AE, Dimarco JP, Ellenbogen KA, et al. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: Executive Summary. A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation 2008;52:1122-1127
    • (2008) Circulation , vol.52 , pp. 1122-1127
    • Epstein, A.E.1    Dimarco, J.P.2    Ellenbogen, K.A.3
  • 3
    • 33748863805 scopus 로고    scopus 로고
    • ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death-executive summary: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines
    • Zipes DP, Camm AJ, Borggrefe M, et al. ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death-executive summary: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines. Eur Heart J 2006;27:2099-2140
    • (2006) Eur Heart J , vol.27 , pp. 2099-2140
    • Zipes, D.P.1    Camm, A.J.2    Borggrefe, M.3
  • 4
    • 51749098549 scopus 로고    scopus 로고
    • A critical appraisal of implantable cardioverter-defibrillator therapy for the prevention of sudden cardiac death
    • Tung R, Zimetbaum P, Josephson ME. A critical appraisal of implantable cardioverter-defibrillator therapy for the prevention of sudden cardiac death. J Am Coll Cardiol 2008;52:1111-1121
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1111-1121
    • Tung, R.1    Zimetbaum, P.2    Josephson, M.E.3
  • 7
    • 34347217872 scopus 로고    scopus 로고
    • Optimising the dichotomy limit for left ventricular ejection fraction in selecting patients for defibrillator therapy after myocardial infarction
    • DOI 10.1136/hrt.2006.102186
    • Yap YG, Duong T, Bland JM, et al. Optimising the dichotomy limit for left ventricular ejection fraction in selecting patients for defibrillator therapy after myocardial infarction. Heart 2007;93: 832-836 (Pubitemid 46998983)
    • (2007) Heart , vol.93 , Issue.7 , pp. 832-836
    • Yee, G.Y.1    Duong, T.2    Bland, J.M.3    Malik, M.4    Torp-Pedersen, C.5    Kober, L.6    Gallagher, M.M.7    Camm, A.J.8
  • 9
    • 0031049924 scopus 로고    scopus 로고
    • Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function
    • Otterstad JE, Froeland G, St John Sutton M, Holme I. Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function. Eur Heart J 1997;18:507-513 (Pubitemid 27110484)
    • (1997) European Heart Journal , vol.18 , Issue.3 , pp. 507-513
    • Otterstad, J.E.1    Froeland, G.2    St John Sutton, M.3    Holme, I.4
  • 10
    • 41949106996 scopus 로고    scopus 로고
    • Performance of Conventional Echocardiographic Parameters and Myocardial Measurements in the Sequential Evaluation of Left Ventricular Function
    • DOI 10.1016/j.amjcard.2007.10.037, PII S0002914907021510
    • Hare JL, Brown JK, Marwick TH. Performance of conventional echocardiographic parameters and myocardial measurements in the sequential evaluation of left ventricular function. Am J Cardiol 2008;101:706-711 (Pubitemid 351649349)
    • (2008) American Journal of Cardiology , vol.101 , Issue.5 , pp. 706-711
    • Hare, J.L.1    Brown, J.K.2    Marwick, T.H.3
  • 11
    • 34548505778 scopus 로고    scopus 로고
    • Limitations of ejection fraction for prediction of sudden death risk in patients with coronary artery disease: Lessons from the MUSTT study
    • Buxton AE, Lee KL, Hafley GE, et al. Limitations of ejection fraction for prediction of sudden death risk in patients with coronary artery disease: lessons from the MUSTT study. J Am Coll Cardiol 2007;50:1150-1157
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1150-1157
    • Buxton, A.E.1    Lee, K.L.2    Hafley, G.E.3
  • 13
    • 20544467414 scopus 로고    scopus 로고
    • Sudden death after myocardial infarction - Who needs prophylaxis, and when?
    • DOI 10.1056/NEJMe058085
    • Buxton AE. Sudden death after myocardial infarction - who needs prophylaxis, and when? N Engl J Med 2005;352:2638-2640 (Pubitemid 41007851)
    • (2005) New England Journal of Medicine , vol.352 , Issue.25 , pp. 2638-2640
    • Buxton, A.E.1
  • 15
    • 27144479420 scopus 로고    scopus 로고
    • Reduced ejection fraction after myocardial infarction: Is it sufficient to justify implantation of a defibrillator?
    • DOI 10.1378/chest.128.4.2626
    • Pascale P, Taffe P, Regamey C, Kappenberger L, Fromer M. Reduced ejection fraction after myocardial infarction: is it sufficient to justify implantation of a defibrillator? Chest 2005;128:2626-2632 (Pubitemid 41507620)
    • (2005) Chest , vol.128 , Issue.4 , pp. 2626-2632
    • Pascale, P.1    Taffe, P.2    Regamey, C.3    Kappenberger, L.4    Fromer, M.5
  • 16
    • 38149022686 scopus 로고    scopus 로고
    • Risk stratification for primary implantation of a cardioverter- defibrillator in patients with ischemic left ventricular dysfunction
    • Goldenberg I, Vyas AK, Hall WJ, et al. Risk stratification for primary implantation of a cardioverter-defibrillator in patients with ischemic left ventricular dysfunction. J Am Coll Cardiol 2008;51:288-296
    • (2008) J Am Coll Cardiol , vol.51 , pp. 288-296
    • Goldenberg, I.1    Vyas, A.K.2    Hall, W.J.3
  • 17
    • 33847403128 scopus 로고    scopus 로고
    • Poor prognosis for patients with chronic kidney disease despite ICD therapy for the primary prevention of sudden death
    • Cuculich PS, Sánchez JM, Kerzner R, et al. Poor prognosis for patients with chronic kidney disease despite ICD therapy for the primary prevention of sudden death. PACE 2007;30:207-213
    • (2007) PACE , vol.30 , pp. 207-213
    • Cuculich, P.S.1    Sánchez, J.M.2    Kerzner, R.3
  • 19
    • 33646130849 scopus 로고    scopus 로고
    • Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories
    • Gould PA, Krahn AD. Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories. JAMA 2006;295:1907-1911
    • (2006) JAMA , vol.295 , pp. 1907-1911
    • Gould, P.A.1    Krahn, A.D.2
  • 20
    • 34248579318 scopus 로고    scopus 로고
    • Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years
    • DOI 10.1161/CIRCULATIONAHA.106.663807
    • Kleemann T, Becker T, Doenges K, et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Circulation 2007;115 2474-2480 (Pubitemid 46763220)
    • (2007) Circulation , vol.115 , Issue.19 , pp. 2474-2480
    • Kleemann, T.1    Becker, T.2    Doenges, K.3    Vater, M.4    Senges, J.5    Schneider, S.6    Saggau, W.7    Weisse, U.8    Seidl, K.9
  • 21
    • 13244260702 scopus 로고    scopus 로고
    • Implantable cardioverter-defibrillators, induced anxiety, and quality of life
    • Sola CL, Bostwick JM. Implantable cardioverter-defibrillators, induced anxiety, and quality of life. Mayo Clin Proc 2005;80:232-237 (Pubitemid 40194537)
    • (2005) Mayo Clinic Proceedings , vol.80 , Issue.2 , pp. 232-237
    • Sola, C.L.1    Bostwick, J.M.2
  • 23
    • 20444492445 scopus 로고    scopus 로고
    • Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter defibrillator patients: Results from the pacing fast VT REduces shock ThErapies (PainFREE Rx II) trial
    • DOI 10.1161/CIRCULATIONAHA.104.526673
    • Sweeney MO, Wathen MS, Volosin K, et al. Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter defibrillator patients: results from the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) trial. Circulation 2005;111:2898-2905 (Pubitemid 40814182)
    • (2005) Circulation , vol.111 , Issue.22 , pp. 2898-2905
    • Sweeney, M.O.1    Wathen, M.S.2    Volosin, K.3    Abdalla, I.4    Degroot, P.J.5    Otterness, M.F.6    Stark, A.J.7
  • 24
    • 41149165849 scopus 로고    scopus 로고
    • Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: Frequency, mechanisms, predictors, and survival impact
    • Daubert JP, Zareba W, Cannom DS, et al. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol 2008;51:1357-1365
    • (2008) J Am Coll Cardiol , vol.51 , pp. 1357-1365
    • Daubert, J.P.1    Zareba, W.2    Cannom, D.S.3
  • 26
    • 3242742134 scopus 로고    scopus 로고
    • High incidence of appropriate and inappropriate ICD therapies in children and adolescents with implantable cardioverter defibrillator
    • Korte T, Köditz H, Niehaus M, Paul T, Tebbenjohanns J. High incidence of appropriate and inappropriate ICD therapies in children and adolescents with implantable cardioverter defibrillator. PACE 2004;27:924-932
    • (2004) PACE , vol.27 , pp. 924-932
    • Korte, T.1    Köditz, H.2    Niehaus, M.3    Paul, T.4    Tebbenjohanns, J.5
  • 27
    • 33747070017 scopus 로고    scopus 로고
    • Cost-effectiveness of defibrillator therapy or amiodarone in chronic stable heart failure: Results from the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT)
    • Mark DB, Nelson CL, Anstrom KJ, et al. Cost-effectiveness of defibrillator therapy or amiodarone in chronic stable heart failure: results from the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT). Circulation 2006;114:135-142
    • (2006) Circulation , vol.114 , pp. 135-142
    • Mark, D.B.1    Nelson, C.L.2    Anstrom, K.J.3
  • 29
    • 34547750422 scopus 로고    scopus 로고
    • Role of the implantable defibrillator among elderly patients with a history of life-threatening ventricular arrhythmias
    • Healey JS, Hallstrom AP, Kuck KH, et al. Role of the implantable defibrillator among elderly patients with a history of life-threatening ventricular arrhythmias. Eur Heart J 2007;28:1746-1749
    • (2007) Eur Heart J , vol.28 , pp. 1746-1749
    • Healey, J.S.1    Hallstrom, A.P.2    Kuck, K.H.3
  • 30
    • 40849102512 scopus 로고    scopus 로고
    • Outcomes of elderly heart failure recipients of ICD and CRT
    • Grimm W. Outcomes of elderly heart failure recipients of ICD and CRT. Int J Cardiol 2008;125:154-160
    • (2008) Int J Cardiol , vol.125 , pp. 154-160
    • Grimm, W.1
  • 31
    • 33644870367 scopus 로고    scopus 로고
    • Are implantable cardioverter defibrillator shocks a surrogate for sudden cardiac death in patients with nonischemic cardiomyopathy?
    • Ellenbogen KA, Levine JH, Berger RD, et al. Are implantable cardioverter defibrillator shocks a surrogate for sudden cardiac death in patients with nonischemic cardiomyopathy? Circulation 2006;113:776-782
    • (2006) Circulation , vol.113 , pp. 776-782
    • Ellenbogen, K.A.1    Levine, J.H.2    Berger, R.D.3
  • 32
    • 34547887988 scopus 로고    scopus 로고
    • Clinical implementation of guidelines for cardioverter defibrillator implantation: Lost in translation?
    • Borleffs CJ, Wilde AA, Cramer MJ, Wever E, Mosterd A. Clinical implementation of guidelines for cardioverter defibrillator implantation: lost in translation? Neth Heart J 2007;15:129-132 (Pubitemid 47253679)
    • (2007) Netherlands Heart Journal , vol.15 , Issue.4 , pp. 129-132
    • Borleffs, C.J.W.1    Wilde, A.A.M.2    Cramer, M.J.M.3    Wever, E.4    Mosterd, A.5
  • 33
    • 34247106224 scopus 로고    scopus 로고
    • Clinical trials in the elderly-a concept comes of age
    • Siu LL. Clinical trials in the elderly-a concept comes of age. New Engl J Med 2007;356:1575-1576
    • (2007) New Engl J Med , vol.356 , pp. 1575-1576
    • Siu, L.L.1
  • 34
    • 3142667620 scopus 로고    scopus 로고
    • Long-term comparison of the implantable cardioverter defibrillator versus amiodarone: Eleven-year follow-up of a subset of patients in the Canadian Implantable Defibrillator Study (CIDS)
    • DOI 10.1161/01.CIR.0000134957.51747.6E
    • Bokhari F, Newman D, Greene M, Korley V, Mangat I, Dorian P. Long-term comparison of the implantable cardioverter defibrillator versus amiodarone: eleven-year follow-up of a subset of patients in the Canadian Implantable Defibrillator Study (CIDS). Circulation 2004;110:112-116 (Pubitemid 38924577)
    • (2004) Circulation , vol.110 , Issue.2 , pp. 112-116
    • Bokhari, F.1    Newman, D.2    Greene, M.3    Korley, V.4    Mangat, I.5    Dorian, P.6
  • 35
    • 0030695327 scopus 로고    scopus 로고
    • Out-of-hospital cardiac arrest in the 1990's: A population-based study in the Maastricht area on incidence, characteristics and survival
    • de Vreede-Swagemakers JJ, Gorgels AP, Dubois-Arbouw WI, et al. Out-of-hospital cardiac arrest in the 1990's: a population-based study in the Maastricht area on incidence, characteristics and survival. J Am Coll Cardiol 1997;30:1500-1505
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1500-1505
    • De Vreede-Swagemakers, J.J.1    Gorgels, A.P.2    Dubois-Arbouw, W.I.3
  • 38
    • 37349073421 scopus 로고    scopus 로고
    • Is microvolt T-wave alternans the answer to risk stratification in heart failure?
    • DOI 10.1161/CIRCULATIONAHA.107.699918, PII 0000301720071218000015
    • Myles RC, Jackson CE, Tsorlalis I, Petrie MC, McMurray JJ, Cobbe SM. Is microvolt T-wave alternans the answer to risk stratification in heart failure? Circulation 2007;116:2984-2991 (Pubitemid 350291206)
    • (2007) Circulation , vol.116 , Issue.25 , pp. 2984-2991
    • Myles, R.C.1    Jackson, C.E.2    Tsorlalis, I.3    Petrie, M.C.4    McMurray, J.J.V.5    Cobbe, S.M.6
  • 39
    • 0033551079 scopus 로고    scopus 로고
    • Prediction of sustained ventricular tachycardia inducible by programmed stimulation in patients with coronary artery disease. Utility of clinical variables
    • Buxton AE, Hafley GE, Lehmann MH, et al. Prediction of sustained ventricular tachycardia inducible by programmed stimulation in patients with coronary artery disease. Utility of clinical variables. Circulation 1999;99:1843-1850
    • (1999) Circulation , vol.99 , pp. 1843-1850
    • Buxton, A.E.1    Hafley, G.E.2    Lehmann, M.H.3
  • 40
    • 33748640974 scopus 로고    scopus 로고
    • Familial sudden death is an important risk factor for primary ventricular fibrillation: A case-control study in acute myocardial infarction patients
    • Dekker LR, Bezzina CR, Henriques JP, et al. Familial sudden death is an important risk factor for primary ventricular fibrillation: a case-control study in acute myocardial infarction patients. Circulation 2006;114:1140-1145
    • (2006) Circulation , vol.114 , pp. 1140-1145
    • Dekker, L.R.1    Bezzina, C.R.2    Henriques, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.