메뉴 건너뛰기




Volumn 50, Issue 9, 2009, Pages 4121-4128

Evidence for a relative thinning of the peripheral cornea with age in white european subjects

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGE; AGED; ARTICLE; CORNEA CURVATURE; CORNEA THICKNESS; EUROPE; HUMAN; MAJOR CLINICAL STUDY; PACHYMETRY; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; REFRACTIVE SURGERY; REGRESSION ANALYSIS; VISUAL SYSTEM EXAMINATION; ADOLESCENT; AGING; CAUCASIAN; CORNEA; HISTOLOGY; MIDDLE AGED; MORPHOMETRICS; PHYSIOLOGY;

EID: 70349251357     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.08-3298     Document Type: Article
Times cited : (21)

References (38)
  • 1
    • 55149086921 scopus 로고
    • Measurements of the effect of solutions of different osmotic pressure on the thickness of the living cornea
    • Von Bahr G. Measurements of the effect of solutions of different osmotic pressure on the thickness of the living cornea. Trans Am Ophthalmol Soc. 1948;68:515-524.
    • (1948) Trans Am Ophthalmol Soc , vol.68 , pp. 515-524
    • von Bahr, G.1
  • 2
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 3
    • 0036908815 scopus 로고    scopus 로고
    • Assessments of corneal endothelial cell density in growing children and its relationship to horizontal corneal diameter
    • Müller A, Doughty MJ. Assessments of corneal endothelial cell density in growing children and its relationship to horizontal corneal diameter. Optom Vis Sci. 2002;79:762-770.
    • (2002) Optom Vis Sci , vol.79 , pp. 762-770
    • Müller, A.1    Doughty, M.J.2
  • 4
    • 0014238551 scopus 로고
    • Central and peripheral corneal thickness: A clinical study
    • Martola EL, Baum JL. Central and peripheral corneal thickness: a clinical study. Arch Ophthalmol. 1968;79:28-30.
    • (1968) Arch Ophthalmol , vol.79 , pp. 28-30
    • Martola, E.L.1    Baum, J.L.2
  • 5
    • 0027400408 scopus 로고
    • The effect of age on human corneal thickness: Statistical implications of power analysis
    • Siu A, Herse P. The effect of age on human corneal thickness: statistical implications of power analysis. Acta Ophthalmol (Copenh). 1993;71:51-56.
    • (1993) Acta Ophthalmol (Copenh) , vol.71 , pp. 51-56
    • Siu, A.1    Herse, P.2
  • 6
    • 13944275573 scopus 로고    scopus 로고
    • Orbscan computerized topography: Attributes, applications, and limitations
    • Cairns G, McGhee CN. Orbscan computerized topography: attributes, applications, and limitations. J Cataract Refract Surg. 2005;31:205-220.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 205-220
    • Cairns, G.1    McGhee, C.N.2
  • 8
    • 33846000997 scopus 로고    scopus 로고
    • Age-related changes in central and peripheral corneal thickness: Determination of normal values with the Orbscan II topography system
    • Rüfer F, Schröder A, Bader C, Erb C. Age-related changes in central and peripheral corneal thickness: determination of normal values with the Orbscan II topography system. Cornea. 2007;26:1-5.
    • (2007) Cornea , vol.26 , pp. 1-5
    • Rüfer, F.1    Schröder, A.2    Bader, C.3    Erb, C.4
  • 9
    • 33947575538 scopus 로고    scopus 로고
    • An assessment of regional differences in corneal thickness in normal human eyes, using the Orbscan II or ultrasound pachymetry
    • Doughty MJ, Jonuscheit S. An assessment of regional differences in corneal thickness in normal human eyes, using the Orbscan II or ultrasound pachymetry. Optometry. 2007;78:181-190.
    • (2007) Optometry , vol.78 , pp. 181-190
    • Doughty, M.J.1    Jonuscheit, S.2
  • 10
    • 14744278223 scopus 로고    scopus 로고
    • Zentrale und periphere Hornhautpachymetrie: Normevaluation mit dem Pentacam-System
    • Rüfer F, Schröder A, Arvani M-K. Zentrale und periphere Hornhautpachymetrie: Normevaluation mit dem Pentacam-System. Klin Monatsbl Augenheilkd. 2005;222:117-122.
    • (2005) Klin Monatsbl Augenheilkd , vol.222 , pp. 117-122
    • Rüfer, F.1    Schröder, A.2    Arvani, M.-K.3
  • 11
    • 58149238183 scopus 로고    scopus 로고
    • Thickness mapping of the cornea and epithelium using optical coherence tomography
    • Haque S, Jones L, Simpson T. Thickness mapping of the cornea and epithelium using optical coherence tomography. Optom Vis Sci. 2008;85:E963-E976.
    • (2008) Optom Vis Sci , vol.85
    • Haque, S.1    Jones, L.2    Simpson, T.3
  • 12
    • 0036896206 scopus 로고    scopus 로고
    • Corneal thickness indices discriminate between keratoconus and contact lens-induced corneal thinning
    • Pflugfelder SC, Liu Z, Feuer W, Verm A. Corneal thickness indices discriminate between keratoconus and contact lens-induced corneal thinning. Ophthalmology. 2002;109:2336-2341.
    • (2002) Ophthalmology , vol.109 , pp. 2336-2341
    • Pflugfelder, S.C.1    Liu, Z.2    Feuer, W.3    Verm, A.4
  • 13
    • 64849108185 scopus 로고    scopus 로고
    • Repeatability of central corneal thickness measures by Orbscan pachymetry in right and left eyes
    • Jonuscheit S, Doughty MJ. Repeatability of central corneal thickness measures by Orbscan pachymetry in right and left eyes. Eye Contact Lens. 2009;35:20-25.
    • (2009) Eye Contact Lens , vol.35 , pp. 20-25
    • Jonuscheit, S.1    Doughty, M.J.2
  • 14
    • 0030757559 scopus 로고    scopus 로고
    • Current keratoconus detection methods compared with a neural network approach
    • Smolek MK, Klyce SD. Current keratoconus detection methods compared with a neural network approach. Invest Ophthalmol Vis Sci. 1997;38:2290-2299.
    • (1997) Invest Ophthalmol Vis Sci , vol.38 , pp. 2290-2299
    • Smolek, M.K.1    Klyce, S.D.2
  • 16
    • 0030732383 scopus 로고    scopus 로고
    • Evaluation of central and peripheral corneal thickness with ultrasound biomicroscopy in normal and keratoconic eyes
    • AvitabileT, Marano F, Uva MG, Reibaldi A. Evaluation of central and peripheral corneal thickness with ultrasound biomicroscopy in normal and keratoconic eyes. Cornea. 1997;16:639-644.
    • (1997) Cornea , vol.16 , pp. 639-644
    • Avitabile, T.1    Marano, F.2    Uva, M.G.3    Reibaldi, A.4
  • 17
    • 4744376301 scopus 로고    scopus 로고
    • A computer-assisted ultrabiomicroscopic method compared with videokeratographic analysis
    • Avitabile T, Franco L, Ortisi E, et al. A computer-assisted ultrabiomicroscopic method compared with videokeratographic analysis. Cornea. 2004;23:655-660.
    • (2004) Cornea , vol.23 , pp. 655-660
    • Avitabile, T.1    Franco, L.2    Ortisi, E.3
  • 18
    • 58149156608 scopus 로고    scopus 로고
    • Contact lens-induced corneal peripheral swelling differences with extended wear
    • Martin R, De Juan V, Rodriguez G, Fonsella S, Martin S. Contact lens-induced corneal peripheral swelling differences with extended wear. Cornea. 2008;27:976-979.
    • (2008) Cornea , vol.27 , pp. 976-979
    • Martin, R.1    de Juan, V.2    Rodriguez, G.3    Fonsella, S.4    Martin, S.5
  • 19
    • 33846236968 scopus 로고    scopus 로고
    • Regional repeatability measures of corneal thickness: Orbscan II and ultrasound
    • Jonuscheit S, Doughty MJ. Regional repeatability measures of corneal thickness: Orbscan II and ultrasound. Optom Vis Sci. 2007; 84:52-58.
    • (2007) Optom Vis Sci , vol.84 , pp. 52-58
    • Jonuscheit, S.1    Doughty, M.J.2
  • 20
    • 37349056419 scopus 로고    scopus 로고
    • Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements
    • Shankar H, Taranath D, Santhirathelagan CT, Pesudovs K. Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements. J Cataract Refract Surg. 2008;34:103-113.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 103-113
    • Shankar, H.1    Taranath, D.2    Santhirathelagan, C.T.3    Pesudovs, K.4
  • 21
    • 67650585854 scopus 로고    scopus 로고
    • Characterization of the thinnest point of the cornea compared with the central corneal thickness in normal subjects
    • Rüfer F, Sander S, Klettner A, Frimpong-Boateng A, Erb C. Characterization of the thinnest point of the cornea compared with the central corneal thickness in normal subjects. Cornea. 2009;28: 177-180.
    • (2009) Cornea , vol.28 , pp. 177-180
    • Rüfer, F.1    Sander, S.2    Klettner, A.3    Frimpong-Boateng, A.4    Erb, C.5
  • 22
    • 60749123573 scopus 로고    scopus 로고
    • The relationship of central corneal thickness (CCT) to thinnest central cornea (TCC) in healthy adults
    • Ashwin PT, Shah S, Pushpoth S, Wehbeh L, Ilango B. The relationship of central corneal thickness (CCT) to thinnest central cornea (TCC) in healthy adults. Contact Lens Anterior Eye. 2009;32(2): 64-67.
    • (2009) Contact Lens Anterior Eye , vol.32 , Issue.2 , pp. 64-67
    • Ashwin, P.T.1    Shah, S.2    Pushpoth, S.3    Wehbeh, L.4    Ilango, B.5
  • 23
    • 0036831268 scopus 로고    scopus 로고
    • Central corneal thickness in European (white) individuals, especially children and the elderly, and assessment of its possible importance in clinical measures of intra-ocular pressure
    • Doughty MJ, Laiquzzaman M, Müller A, Oblak E, Button NF. Central corneal thickness in European (white) individuals, especially children and the elderly, and assessment of its possible importance in clinical measures of intra-ocular pressure. Ophthalmic Physiol Opt. 2002;22:491-504.
    • (2002) Ophthalmic Physiol Opt , vol.22 , pp. 491-504
    • Doughty, M.J.1    Laiquzzaman, M.2    Müller, A.3    Oblak, E.4    Button, N.F.5
  • 24
    • 0014648955 scopus 로고
    • Central corneal thickness: Ocular correlations in normal eyes and those with primary angle-closure glaucoma
    • Lowe RF. Central corneal thickness: ocular correlations in normal eyes and those with primary angle-closure glaucoma. Br J Ophthalmol. 1969;53(12):824-826.
    • (1969) Br J Ophthalmol , vol.53 , Issue.12 , pp. 824-826
    • Lowe, R.F.1
  • 25
    • 0020385128 scopus 로고
    • Central corneal endothelial cell density and central corneal thickness in ocular hypertension and primary open-angle glaucoma
    • Nov
    • Korey M, Gieser D, Kass MA, Waltman SR, Gordon M, Becker B. Central corneal endothelial cell density and central corneal thickness in ocular hypertension and primary open-angle glaucoma. Am J Ophthalmol. 1982 Nov;94(5):610-616.
    • (1982) Am J Ophthalmol , vol.94 , Issue.5 , pp. 610-616
    • Korey, M.1    Gieser, D.2    Kass, M.A.3    Waltman, S.R.4    Gordon, M.5    Becker, B.6
  • 26
    • 0023696282 scopus 로고
    • Variations in human corneal endothelial cell morphology and permeability to fluorescein with age
    • Carlson KH, Bourne WM, McLaren JW, Brubaker RP. Variations in human corneal endothelial cell morphology and permeability to fluorescein with age. Exp Eye Res. 1988;47:27-41.
    • (1988) Exp Eye Res , vol.47 , pp. 27-41
    • Carlson, K.H.1    Bourne, W.M.2    McLaren, J.W.3    Brubaker, R.P.4
  • 27
    • 38249003603 scopus 로고
    • The contact lens induced overnight corneal swelling response of a daily wear adapted sample
    • Cox I, Zantos S, Erickson P. The contact lens induced overnight corneal swelling response of a daily wear adapted sample. ICLC. 1993;20:136-139.
    • (1993) ICLC , vol.20 , pp. 136-139
    • Cox, I.1    Zantos, S.2    Erickson, P.3
  • 28
    • 0030963090 scopus 로고    scopus 로고
    • Distribution of central corneal thickness and its associations with intraocular pressure: The Rotterdam Study
    • Wolfs RC, Klaver CC, Vingerling JR, et al. Distribution of central corneal thickness and its associations with intraocular pressure: The Rotterdam Study. Am J Ophthamol. 1997;123:767-772.
    • (1997) Am J Ophthamol , vol.123 , pp. 767-772
    • Wolfs, R.C.1    Klaver, C.C.2    Vingerling, J.R.3
  • 29
    • 26944502270 scopus 로고    scopus 로고
    • Caucasian emmetropic aged subjects have reduced corneal thicknesses: Emmetropia, CCT and age
    • Sanchis-Gimeno JA, Lleó-Pérez A, Alonso L, Rahhal MS. Caucasian emmetropic aged subjects have reduced corneal thicknesses: emmetropia, CCT and age. Int Ophthalmol. 2004;25:243-246.
    • (2004) Int Ophthalmol , vol.25 , pp. 243-246
    • Sanchis-Gimeno, J.A.1    Lleó-Pérez, A.2    Alonso, L.3    Rahhal, M.S.4
  • 30
    • 0014980777 scopus 로고
    • A clinical study of the normal human central corneal thickness
    • Krus Hansen F. A clinical study of the normal human central corneal thickness. Acta Ophthalmol (Copenh). 1971;49:82-89.
    • (1971) Acta Ophthalmol(Copenh) , vol.49 , pp. 82-89
    • Krus, H.F.1
  • 31
    • 0021845133 scopus 로고
    • Changes in the normal corneal endothelial cellular pattern as a function of age
    • Yee RW, Matsuda M, Schultz RO, Edelhauser HF. Changes in the normal corneal endothelial cellular pattern as a function of age. Curr Eye Res. 1985;4:671-678.
    • (1985) Curr Eye Res , vol.4 , pp. 671-678
    • Yee, R.W.1    Matsuda, M.2    Schultz, R.O.3    Edelhauser, H.F.4
  • 32
    • 0027768324 scopus 로고
    • Nine point corneal thickness measurements and keratometry readings in normal corneas using ultrasound pachymetry
    • Rapuano CJ, Fishbaugh JA, Strike DJ. Nine point corneal thickness measurements and keratometry readings in normal corneas using ultrasound pachymetry. Insight. 1993;18(4):16 -22.
    • (1993) Insight , vol.18 , Issue.4 , pp. 16-22
    • Rapuano, C.J.1    Fishbaugh, J.A.2    Strike, D.J.3
  • 33
    • 55149087036 scopus 로고    scopus 로고
    • Goldmann tonometry and pachymetry measures in patients with and without topical medical treatment at a glaucoma clinic
    • Doughty MJ, Gillis N, MacGill J, Montgomery DM. Goldmann tonometry and pachymetry measures in patients with and without topical medical treatment at a glaucoma clinic. Ophthalmic Physiol Optics. 2008;28:558-567.
    • (2008) Ophthalmic Physiol Optics , vol.28 , pp. 558-567
    • Doughty, M.J.1    Gillis, N.2    Macgill, J.3    Montgomery, D.M.4
  • 34
    • 34848825022 scopus 로고    scopus 로고
    • Effect of central corneal thickness on Goldmann applanation tonometry measures: A different result with different pachymeters
    • Doughty MJ, Jonuscheit S. Effect of central corneal thickness on Goldmann applanation tonometry measures: a different result with different pachymeters. Graefes Arch Clin Exp Ophthalmol. 2007; 245:1603-1610.
    • (2007) Graefes Arch Clin Exp Ophthalmol , vol.245 , pp. 1603-1610
    • Doughty, M.J.1    Jonuscheit, S.2
  • 35
    • 0028194831 scopus 로고    scopus 로고
    • Improving estimation of corneal refractive power by measuring the posterior curvature of the cornea
    • Eryildrim A, Ozkan T, Eryildrim S, Kaynak S, Cingil G. Improving estimation of corneal refractive power by measuring the posterior curvature of the cornea. J Cataract Refract Surg. 2004;20:129-131.
    • (2004) J Cataract Refract Surg , vol.20 , pp. 129-131
    • Eryildrim, A.1    Ozkan, T.2    Eryildrim, S.3    Kaynak, S.4    Cingil, G.5
  • 36
    • 34447310022 scopus 로고    scopus 로고
    • Corneal arcus as coronary artery disease risk factor
    • Fernandez A, Sorokin A, Thompson PD. Corneal arcus as coronary artery disease risk factor. Atherosclerosis. 2007;193:235-240.
    • (2007) Atherosclerosis , vol.193 , pp. 235-240
    • Fernandez, A.1    Sorokin, A.2    Thompson, P.D.3
  • 37
    • 41749113099 scopus 로고    scopus 로고
    • Correlating corneal arcus with atherosclerosis in familial hypercholesterolemia
    • Zech LA, Hoeg JM. Correlating corneal arcus with atherosclerosis in familial hypercholesterolemia. Lipids Health Dis. 2008;10:7:7.
    • (2008) Lipids Health Dis , vol.10 , Issue.7 , pp. 7
    • Zech, L.A.1    Hoeg, J.M.2
  • 38
    • 0015893946 scopus 로고
    • Posterior corneal curvature: Correlations in normal eyes and in eyes involved with primary angle-closure glaucoma
    • Lowe RF, Clark BA. Posterior corneal curvature: correlations in normal eyes and in eyes involved with primary angle-closure glaucoma. Br J Ophthalmol. 1973;57:464-470.
    • (1973) Br J Ophthalmol , vol.57 , pp. 464-470
    • Lowe, R.F.1    Clark, B.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.