Impact of Vessel Size on Angiographic and Clinical Outcomes of Revascularization With Biolimus-Eluting Stent With Biodegradable Polymer and Sirolimus-Eluting Stent With Durable Polymer. The LEADERS Trial Substudy

(17)  Wykrzykowska, Joanna J a   Serruys, Patrick W a   Onuma, Yoshinobu a   de Vries, Ton b   van Es, Gerrit Anne b   Buszman, Pawel c   Linke, Axel d   Ischinger, Thomas e   Klauss, Volker f   Corti, Roberto g   Eberli, Franz g,l   Wijns, William h   Morice, Marie Claude i   di Mario, Carlo j   van Geuns, Robert Jan a   Juni, Peter k   Windecker, Stephan k  


Author keywords

biodegradable polymer; biolimus eluting stent; long lesions; sirolimus eluting stent; small vessels; target vessel revascularization

Indexed keywords

BIOLIMUS; RAPAMYCIN; RAPAMYCIN DERIVATIVE; UNCLASSIFIED DRUG;

EID: 70349235710     PISSN: 19368798     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcin.2009.05.024     Document Type: Article
Times cited : (48)

References (22)
  • 1
    • 53149141718 scopus 로고    scopus 로고
    • Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial
    • Windecker S., Serruys P.W., Wandel S., et al. Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial. Lancet 372 (2008) 1163-1173
    • (2008) Lancet , vol.372 , pp. 1163-1173
    • Windecker, S.1    Serruys, P.W.2    Wandel, S.3
  • 2
    • 33845879078 scopus 로고    scopus 로고
    • BioMatrix Biolimus A9-eluting coronary stent: a next-generation drug-eluting stent for coronary artery disease
    • Grube E., and Buellesfeld L. BioMatrix Biolimus A9-eluting coronary stent: a next-generation drug-eluting stent for coronary artery disease. Expert Rev Med Devices 3 (2006) 731-741
    • (2006) Expert Rev Med Devices , vol.3 , pp. 731-741
    • Grube, E.1    Buellesfeld, L.2
  • 3
    • 27844607833 scopus 로고    scopus 로고
    • Robustness of late lumen loss in discriminating drug-eluting stents across variable observational and randomized trials
    • Mauri L., Orav E.J., Candia S.C., Cutlip D.E., and Kuntz R.E. Robustness of late lumen loss in discriminating drug-eluting stents across variable observational and randomized trials. Circulation 112 (2005) 2833-2839
    • (2005) Circulation , vol.112 , pp. 2833-2839
    • Mauri, L.1    Orav, E.J.2    Candia, S.C.3    Cutlip, D.E.4    Kuntz, R.E.5
  • 4
    • 21544438170 scopus 로고    scopus 로고
    • Late loss in lumen diameter and binary restenosis for drug-eluting stent comparison
    • Mauri L., Orav E.J., and Kuntz R.E. Late loss in lumen diameter and binary restenosis for drug-eluting stent comparison. Circulation 111 (2005) 3435-3442
    • (2005) Circulation , vol.111 , pp. 3435-3442
    • Mauri, L.1    Orav, E.J.2    Kuntz, R.E.3
  • 5
    • 19944430230 scopus 로고    scopus 로고
    • Relationship of late loss in lumen diameter to coronary restenosis in sirolimus-eluting stents
    • Mauri L., Orav E.J., O'Malley A.J., et al. Relationship of late loss in lumen diameter to coronary restenosis in sirolimus-eluting stents. Circulation 111 (2005) 321-327
    • (2005) Circulation , vol.111 , pp. 321-327
    • Mauri, L.1    Orav, E.J.2    O'Malley, A.J.3
  • 6
    • 33646086710 scopus 로고    scopus 로고
    • Sirolimus-eluting coronary stents in small vessels
    • Meier B., Sousa E., Guagliumi G., et al. Sirolimus-eluting coronary stents in small vessels. Am Heart J 151 (2006) 1019.e1-1019.e7
    • (2006) Am Heart J , vol.151
    • Meier, B.1    Sousa, E.2    Guagliumi, G.3
  • 7
    • 0026592026 scopus 로고
    • The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting
    • Kuntz R.E., Safian R.D., Carrozza J.P., Fishman R.F., Mansour M., and Baim D.S. The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. Circulation 86 (1992) 1827-1835
    • (1992) Circulation , vol.86 , pp. 1827-1835
    • Kuntz, R.E.1    Safian, R.D.2    Carrozza, J.P.3    Fishman, R.F.4    Mansour, M.5    Baim, D.S.6
  • 8
    • 0026740270 scopus 로고
    • Novel approach to the analysis of restenosis after the use of three new coronary devices
    • Kuntz R.E., Safian R.D., Levine M.J., Reis G.J., Diver D.J., and Baim D.S. Novel approach to the analysis of restenosis after the use of three new coronary devices. J Am Coll Cardiol 19 (1992) 1493-1499
    • (1992) J Am Coll Cardiol , vol.19 , pp. 1493-1499
    • Kuntz, R.E.1    Safian, R.D.2    Levine, M.J.3    Reis, G.J.4    Diver, D.J.5    Baim, D.S.6
  • 9
    • 34548474093 scopus 로고    scopus 로고
    • Impact of vessel size on outcome after implantation of sirolimus-eluting and paclitaxel-eluting stents: a subgroup analysis of the SIRTAX trial
    • Togni M., Eber S., Widmer J., et al. Impact of vessel size on outcome after implantation of sirolimus-eluting and paclitaxel-eluting stents: a subgroup analysis of the SIRTAX trial. J Am Coll Cardiol 50 (2007) 1123-1131
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1123-1131
    • Togni, M.1    Eber, S.2    Widmer, J.3
  • 10
    • 20244371040 scopus 로고    scopus 로고
    • Relationship between angiographic late loss and target lesion revascularization after coronary stent implantation: analysis from the TAXUS-IV trial
    • Ellis S.G., Popma J.J., Lasala J.M., et al. Relationship between angiographic late loss and target lesion revascularization after coronary stent implantation: analysis from the TAXUS-IV trial. J Am Coll Cardiol 45 (2005) 1193-1200
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1193-1200
    • Ellis, S.G.1    Popma, J.J.2    Lasala, J.M.3
  • 11
    • 0037044449 scopus 로고    scopus 로고
    • Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size
    • Regar E., Serruys P.W., Bode C., et al. Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size. Circulation 106 (2002) 1949-1956
    • (2002) Circulation , vol.106 , pp. 1949-1956
    • Regar, E.1    Serruys, P.W.2    Bode, C.3
  • 13
    • 23844482954 scopus 로고    scopus 로고
    • Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization
    • Windecker S., Remondino A., Eberli F.R., et al. Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization. N Engl J Med 353 (2005) 653-662
    • (2005) N Engl J Med , vol.353 , pp. 653-662
    • Windecker, S.1    Remondino, A.2    Eberli, F.R.3
  • 14
    • 19944425945 scopus 로고    scopus 로고
    • Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis: a randomized controlled trial
    • Kastrati A., Mehilli J., von Beckerath N., et al. Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis: a randomized controlled trial. JAMA 293 (2005) 165-171
    • (2005) JAMA , vol.293 , pp. 165-171
    • Kastrati, A.1    Mehilli, J.2    von Beckerath, N.3
  • 15
    • 33748936659 scopus 로고    scopus 로고
    • Vessel size and outcome after coronary drug-eluting stent placement: results from a large cohort of patients treated with sirolimus- or paclitaxel-eluting stents
    • Elezi S., Dibra A., Mehilli J., et al. Vessel size and outcome after coronary drug-eluting stent placement: results from a large cohort of patients treated with sirolimus- or paclitaxel-eluting stents. J Am Coll Cardiol 48 (2006) 1304-1309
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1304-1309
    • Elezi, S.1    Dibra, A.2    Mehilli, J.3
  • 16
    • 33845999915 scopus 로고    scopus 로고
    • Two-year clinical outcome after coronary stenting of small vessels using 2.25-mm sirolimus- and paclitaxel-eluting stents: insight into the RESEARCH and T-SEARCH registries
    • Tanimoto S., Daemen J., Tsuchida K., et al. Two-year clinical outcome after coronary stenting of small vessels using 2.25-mm sirolimus- and paclitaxel-eluting stents: insight into the RESEARCH and T-SEARCH registries. Catheter Cardiovasc Interv 69 (2007) 94-103
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 94-103
    • Tanimoto, S.1    Daemen, J.2    Tsuchida, K.3
  • 17
    • 58149265063 scopus 로고    scopus 로고
    • Long-term benefit-risk balance of drug-eluting vs. bare-metal stents in daily practice: does stent diameter matter?. Three-year follow-up of BASKET
    • Pfisterer M., Brunner-La Rocca H.P., Rickenbacher P., et al. Long-term benefit-risk balance of drug-eluting vs. bare-metal stents in daily practice: does stent diameter matter?. Three-year follow-up of BASKET. Eur Heart J 30 (2009) 16-24
    • (2009) Eur Heart J , vol.30 , pp. 16-24
    • Pfisterer, M.1    Brunner-La Rocca, H.P.2    Rickenbacher, P.3
  • 18
    • 33745233024 scopus 로고    scopus 로고
    • Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk
    • Joner M., Finn A.V., Farb A., et al. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48 (2006) 193-202
    • (2006) J Am Coll Cardiol , vol.48 , pp. 193-202
    • Joner, M.1    Finn, A.V.2    Farb, A.3
  • 19
    • 67650946144 scopus 로고    scopus 로고
    • Novel high throughput polymer biocompatibility screening designed for SAR (structure-activity relationship): application for evaluating polymer coatings for cardiovascular drug-eluting stents
    • [E-pub ahead of print]
    • Hezi-Yamit A., Sullivan C., Wong J., et al. Novel high throughput polymer biocompatibility screening designed for SAR (structure-activity relationship): application for evaluating polymer coatings for cardiovascular drug-eluting stents. Comb Chem High Throughput Screen (2009 Aug 1) [E-pub ahead of print]
    • (2009) Comb Chem High Throughput Screen
    • Hezi-Yamit, A.1    Sullivan, C.2    Wong, J.3
  • 20
    • 61849104535 scopus 로고    scopus 로고
    • Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease
    • Serruys P.W., Morice M.C., Kappetein A.P., et al. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease. N Engl J Med 360 (2009) 961-972
    • (2009) N Engl J Med , vol.360 , pp. 961-972
    • Serruys, P.W.1    Morice, M.C.2    Kappetein, A.P.3
  • 21
    • 44249122195 scopus 로고    scopus 로고
    • Bivalirudin during primary PCI in acute myocardial infarction
    • Stone G.W., Witzenbichler B., Guagliumi G., et al. Bivalirudin during primary PCI in acute myocardial infarction. N Engl J Med 358 (2008) 2218-2230
    • (2008) N Engl J Med , vol.358 , pp. 2218-2230
    • Stone, G.W.1    Witzenbichler, B.2    Guagliumi, G.3
  • 22
    • 36148983750 scopus 로고    scopus 로고
    • Prasugrel versus clopidogrel in patients with acute coronary syndromes
    • Wiviott S.D., Braunwald E., McCabe C.H., et al. Prasugrel versus clopidogrel in patients with acute coronary syndromes. N Engl J Med 357 (2007) 2001-2015
    • (2007) N Engl J Med , vol.357 , pp. 2001-2015
    • Wiviott, S.D.1    Braunwald, E.2    McCabe, C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.