메뉴 건너뛰기




Volumn 23, Issue 5, 2009, Pages 273-277

A novel electronic algorithm for detecting potentially insufficient anesthesia: Implications for the prevention of intraoperative awareness

Author keywords

Anesthesia awareness; Anesthesia information management system; Awareness during general anesthesia; Intraoperative awareness; Minimum alveolar concentration

Indexed keywords

ANESTHESIA AWARENESS; ANESTHESIA INFORMATION MANAGEMENT SYSTEM; AWARENESS DURING GENERAL ANESTHESIA; INTRAOPERATIVE AWARENESS; MINIMUM ALVEOLAR CONCENTRATION;

EID: 70349235330     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-009-9193-9     Document Type: Article
Times cited : (22)

References (12)
  • 1
    • 33845330591 scopus 로고    scopus 로고
    • Monitoring consciousness: EEG-based measures of anesthetic depth
    • Mashour GA. Monitoring consciousness: EEG-based measures of anesthetic depth. Semin Anesth Perioper Med Pain. 2006; 25: 205-10.
    • (2006) Semin Anesth Perioper Med Pain , vol.25 , pp. 205-210
    • Mashour, G.A.1
  • 2
    • 2542562742 scopus 로고    scopus 로고
    • Bispectral index monitoring to prevent awareness during anaesthesia: The B-Aware randomised controlled trial
    • Myles PS, Leslie K, McNeil J, et al. Bispectral index monitoring to prevent awareness during anaesthesia: The B-Aware randomised controlled trial. Lancet. 2004; 363: 1757-63.
    • (2004) Lancet , vol.363 , pp. 1757-1763
    • Myles, P.S.1    Leslie, K.2    McNeil, J.3
  • 3
    • 40849116197 scopus 로고    scopus 로고
    • Anesthesia awareness and the bispectral index
    • Avidan MS, Zhang L, Burnside BA, et al. Anesthesia awareness and the bispectral index. N Engl J Med. 2008; 358: 1097-108.
    • (2008) N Engl J Med , vol.358 , pp. 1097-1108
    • Avidan, M.S.1    Zhang, L.2    Burnside, B.A.3
  • 4
    • 0028043659 scopus 로고
    • The interaction of fentanyl on the Cp50 of propofol for loss of consciousness and skin incision
    • Smith C, McEwan AI, Jhaveri R, et al. The interaction of fentanyl on the Cp50 of propofol for loss of consciousness and skin incision. Anesthesiology. 1994; 81: 820-8.
    • (1994) Anesthesiology , vol.81 , pp. 820-828
    • Smith, C.1    McEwan, A.I.2    Jhaveri, R.3
  • 5
    • 0030977957 scopus 로고    scopus 로고
    • Reduction of the minimum alveolar concentration of isoflurane by dexmedetomidine
    • Aantaa R, Jaakola ML, Kallio A, et al. Reduction of the minimum alveolar concentration of isoflurane by dexmedetomidine. Anesthesiology. 1997; 86: 1055-60.
    • (1997) Anesthesiology , vol.86 , pp. 1055-1060
    • Aantaa, R.1    Jaakola, M.L.2    Kallio, A.3
  • 6
    • 0042242605 scopus 로고    scopus 로고
    • Age-related iso-MAC charts for isoflurane, sevoflurane and desflurane in man
    • Nickalls RWD, Mapleson WW. Age-related iso-MAC charts for isoflurane, sevoflurane and desflurane in man. Br J Anaesth. 2003; 91: 170-4.
    • (2003) Br J Anaesth , vol.91 , pp. 170-174
    • Nickalls, R.W.D.1    Mapleson, W.W.2
  • 7
    • 0034804148 scopus 로고    scopus 로고
    • Age, minimum alveolar anesthetic concentration, and minimum alveolar anesthetic concentration-awake
    • Eger EI. Age, minimum alveolar anesthetic concentration, and minimum alveolar anesthetic concentration-awake. Anesth Analg. 2001; 93: 947-53.
    • (2001) Anesth Analg , vol.93 , pp. 947-953
    • Eger, E.I.1
  • 8
    • 59649094667 scopus 로고    scopus 로고
    • A retrospective study of intraoperative awareness with methodological implications
    • Mashour GA, Wang LYJ, Turner CR, et al. A retrospective study of intraoperative awareness with methodological implications. Anesth Analg. 2009; 108: 521-6.
    • (2009) Anesth Analg , vol.108 , pp. 521-526
    • Mashour, G.A.1    Wang, L.Y.J.2    Turner, C.R.3
  • 9
    • 33750067987 scopus 로고    scopus 로고
    • An anesthesia information system designed to provide physician-specific feedback improves timely administration of prophylactic antibiotics
    • O'Reilly M, Talsma A, VanRiper S, et al. An anesthesia information system designed to provide physician-specific feedback improves timely administration of prophylactic antibiotics. Anesth Analg. 2006; 103: 908-12.
    • (2006) Anesth Analg , vol.103 , pp. 908-912
    • O'Reilly, M.1    Talsma, A.2    VanRiper, S.3
  • 10
    • 33847221446 scopus 로고    scopus 로고
    • Electronic reminders improve procedure documentation compliance and professional fee reimbursement
    • Kheterpal S, Gupta R, Blum JM, et al. Electronic reminders improve procedure documentation compliance and professional fee reimbursement. Anesth Analg. 2007; 104: 592-7.
    • (2007) Anesth Analg , vol.104 , pp. 592-597
    • Kheterpal, S.1    Gupta, R.2    Blum, J.M.3
  • 11
    • 34147142367 scopus 로고    scopus 로고
    • On-line monitoring of end-tidal propofol concentration in anesthetized patients
    • Takita A, Masui K, Kazama T. On-line monitoring of end-tidal propofol concentration in anesthetized patients. Anesthesiology. 2007; 106: 659-64.
    • (2007) Anesthesiology , vol.106 , pp. 659-664
    • Takita, A.1    Masui, K.2    Kazama, T.3
  • 12
    • 67349130163 scopus 로고    scopus 로고
    • Low minimum alveolar concentration alarm: A standard for prevention of awareness during general anaesthesia maintained by inhalational anaesthetics
    • Umesh G, Jasvindere K, Shetty N. Low minimum alveolar concentration alarm: A standard for prevention of awareness during general anaesthesia maintained by inhalational anaesthetics. J Clin Monit Comput. 2009; 23(3): 185-6.
    • (2009) J Clin Monit Comput , vol.23 , Issue.3 , pp. 185-186
    • Umesh, G.1    Jasvindere, K.2    Shetty, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.