메뉴 건너뛰기




Volumn 30, Issue 8, 2009, Pages 1488-1495

Angiographic and histologic comparison of experimental aneurysms embolized with hydrogel filaments

Author keywords

[No Author keywords available]

Indexed keywords

BARIUM SULFATE; IODINE; MACROGOL; POLYMER; POLYPROPYLENE GLYCOL; UNCLASSIFIED DRUG;

EID: 70349222763     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A1649     Document Type: Article
Times cited : (19)

References (22)
  • 1
    • 0032880391 scopus 로고    scopus 로고
    • Clinical and angiographic results of endosaccular coiling treatment of giant and very large intracranial aneurysms: A 7-year, single-center experience
    • discussion 803-804
    • Gruber A, Killer M, Bavinzski G, et al. Clinical and angiographic results of endosaccular coiling treatment of giant and very large intracranial aneurysms: a 7-year, single-center experience. Neurosurgery 1999;45:793- 803; discussion 803-804
    • (1999) Neurosurgery , vol.45 , pp. 793-803
    • Gruber, A.1    Killer, M.2    Bavinzski, G.3
  • 2
    • 26944466840 scopus 로고    scopus 로고
    • International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion
    • Molyneux AJ, Kerr RS, Yu LM, et al. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet 2005;366:809-817
    • (2005) Lancet , vol.366 , pp. 809-817
    • Molyneux, A.J.1    Kerr, R.S.2    Yu, L.M.3
  • 3
    • 40549133462 scopus 로고    scopus 로고
    • Could late rebleeding overturn the superiority of cranial aneurysm coil embolization over clip ligation seen in the International Subarachnoid Aneurysm Trial?
    • DOI 10.3171/JNS/2008/108/3/0437
    • Mitchell P, Kerr R, Mendelow AD, et al. Could late rebleeding overturn the superiority of cranial aneurysm coil embolization over clip ligation seen in the International Subarachnoid Aneurysm Trial? J Neurosurg 2008; 108:437-442 (Pubitemid 351357973)
    • (2008) Journal of Neurosurgery , vol.108 , Issue.3 , pp. 437-442
    • Mitchell, P.1    Kerr, R.2    Mendelow, A.D.3    Molyneux, A.4
  • 4
    • 38349052919 scopus 로고    scopus 로고
    • Single-center experience of Cerecyte coils in the treatment of intracranial aneurysms: Initial experience and early follow-up results
    • Butteriss D, Gholkar A, Mitra D, et al. Single-center experience of Cerecyte coils in the treatment of intracranial aneurysms: initial experience and early follow-up results. AJNR Am J Neuroradiol 2008;29:53-56
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 53-56
    • Butteriss, D.1    Gholkar, A.2    Mitra, D.3
  • 5
    • 38349059733 scopus 로고    scopus 로고
    • Endovascular treatment of intracranial aneurysms with Matrix detachable coils: Midterm anatomic follow-up from a prospective multicenter registry
    • Pierot L, Leclerc X, Bonafe A, et al. Endovascular treatment of intracranial aneurysms with Matrix detachable coils: midterm anatomic follow-up from a prospective multicenter registry. AJNR Am J Neuroradiol 2008;29:57-61
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 57-61
    • Pierot, L.1    Leclerc, X.2    Bonafe, A.3
  • 6
    • 16844376267 scopus 로고    scopus 로고
    • Evaluation of the stability of small ruptured aneurysms with a small neck after embolization with Guglielmi detachable coils: Correlation between coil packing ratio and coil compaction
    • DOI 10.1227/01.NEU.0000156790.28794.EA
    • Kai Y, Hamada J, Morioka M, et al. Evaluation of the stability of small ruptured aneurysms with a small neck after embolization with Guglielmi detachable coils: correlation between coil packing ratio and coil compaction. Neurosurgery 2005;56:785-92; discussion 785-792 (Pubitemid 40489750)
    • (2005) Neurosurgery , vol.56 , Issue.4 , pp. 785-791
    • Kai, Y.1    Hamada, J.-I.2    Morioka, M.3    Yano, S.4    Kuratsu, J.-I.5
  • 7
    • 29544435350 scopus 로고    scopus 로고
    • The relation between packing and reopening in coiled intracranial aneurysms: A prospective study
    • DOI 10.1007/s00234-005-1446-9
    • Slob MJ, Sluzewski M, van Rooij WJ. The relation between packing and reopening in coiled intracranial aneurysms: a prospective study. Neuroradiology 2005;47:942-945 (Pubitemid 43013281)
    • (2005) Neuroradiology , vol.47 , Issue.12 , pp. 942-945
    • Slob, M.J.1    Sluzewski, M.2    Van Rooij, W.J.3
  • 8
    • 1642541684 scopus 로고    scopus 로고
    • Aneurysm packing with HydroCoil embolic system versus platinum coils: Initial clinical experience
    • Cloft HJ, Kallmes DF. Aneurysm packing with HydroCoil embolic system versus platinum coils: initial clinical experience. AJNR Am J Neuroradiol 2004;25:60-62
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 60-62
    • Cloft, H.J.1    Kallmes, D.F.2
  • 9
    • 33745145837 scopus 로고    scopus 로고
    • Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: Effectsonpacking density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy
    • Gaba RC, Ansari SA, Roy SS, et al. Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effectsonpacking density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy. Stroke 2006;37:1443-1450
    • (2006) Stroke , vol.37 , pp. 1443-1450
    • Gaba, R.C.1    Ansari, S.A.2    Roy, S.S.3
  • 10
    • 33846840776 scopus 로고    scopus 로고
    • A prospective single-center analysis of the safety and efficacy of the HydroCoil embolization system for the treatment of intracranial aneurysms
    • Deshaies EM, Adamo MA, Boulos AS. A prospective single-center analysis of the safety and efficacy of the HydroCoil embolization system for the treatment of intracranial aneurysms. J Neurosurg 2007;106:226-233
    • (2007) J Neurosurg , vol.106 , pp. 226-233
    • Deshaies, E.M.1    Adamo, M.A.2    Boulos, A.S.3
  • 11
    • 65949086787 scopus 로고    scopus 로고
    • Preparation, characterization, and evaluation of radiopaque hydrogel filaments for endovascular embolization
    • Constant MJ, Keeley EM, Cruise GM. Preparation, characterization, and evaluation of radiopaque hydrogel filaments for endovascular embolization. J Biomed Mater Res B Appl Biomater 2009;89:306-313
    • (2009) J Biomed Mater Res B Appl Biomater , vol.89 , pp. 306-313
    • Constant, M.J.1    Keeley, E.M.2    Cruise, G.M.3
  • 12
    • 34748892913 scopus 로고    scopus 로고
    • Hydrogel-coated and platinum coils for intracranial aneurysm embolization compared in three experimental models using computerized angiographic and histologic morphometry
    • Cruise GM, Shum JC, Plenk H Jr. Hydrogel-coated and platinum coils for intracranial aneurysm embolization compared in three experimental models using computerized angiographic and histologic morphometry. J Mater Chem 2007;17:3965-3973
    • (2007) J Mater Chem , vol.17 , pp. 3965-3973
    • Cruise, G.M.1    Shum, J.C.2    Plenk Jr., H.3
  • 13
    • 33749465018 scopus 로고    scopus 로고
    • Pharmacological prevention of serious anaphylactic reactions due to iodinated contrast media: Systematic review
    • DOI 10.1136/bmj.38905.634132.AE
    • Tramer MR, von Elm E, Loubeyre P, et al. Pharmacological prevention of serious anaphylactic reactions due to iodinated contrast media: systematic review. BMJ 2006;333:675 (Pubitemid 44521007)
    • (2006) British Medical Journal , vol.333 , Issue.7570 , pp. 675-678
    • Tramer, M.R.1    Von Elm, E.2    Loubeyre, P.3    Hauser, C.4
  • 14
    • 0024588206 scopus 로고
    • Production of experimental aneurysms at a surgically created arterial bifurcation
    • Forrest MD, O'Reilly GV. Production of experimental aneurysms at a surgically created arterial bifurcation. AJNR Am J Neuroradiol 1989;10:400-402
    • (1989) AJNR Am J Neuroradiol , vol.10 , pp. 400-402
    • Forrest, M.D.1    O'Reilly, G.V.2
  • 15
    • 0033978426 scopus 로고    scopus 로고
    • 1999 ARRS Executive Council Award. Creation of saccular aneurysms in the rabbit: A model suitable for testing endovascular devices American Roentgen Ray Society
    • Altes TA, Cloft HJ, Short JG, et al. 1999 ARRS Executive Council Award. Creation of saccular aneurysms in the rabbit: a model suitable for testing endovascular devices American Roentgen Ray Society. AJR Am J Roentgenol 2000;174:349-354
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 349-354
    • Altes, T.A.1    Cloft, H.J.2    Short, J.G.3
  • 16
    • 0030778130 scopus 로고    scopus 로고
    • Safety and efficacy of endovascular treatment of acutely ruptured aneurysms
    • Raymond J, Roy D. Safety and efficacy of endovascular treatment of acutely ruptured aneurysms. Neurosurgery 1997;41:1235- 45; discussion 1245-1246 (Pubitemid 27524637)
    • (1997) Neurosurgery , vol.41 , Issue.6 , pp. 1235-1246
    • Raymond, J.1    Roy, D.2
  • 17
    • 33947598336 scopus 로고    scopus 로고
    • Observer agreement in the assessment of endovascular aneurysm therapy and aneurysm recurrence
    • Cloft HJ, Kaufmann T, Kallmes DF. Observer agreement in the assessment of endovascular aneurysm therapy and aneurysm recurrence. AJNR Am J Neuroradiol 2007;28:497-500 (Pubitemid 46481891)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.3 , pp. 497-500
    • Cloft, H.J.1    Kaufmann, T.2    Kallmes, D.F.3
  • 18
    • 0030724481 scopus 로고    scopus 로고
    • Endovascular occlusion of experimental aneurysms with detachable coils: Influence of packing density and perioperative anticoagulation
    • DOI 10.1097/00006123-199711000-00028
    • Reul J, Spetzger U, Weis J, et al. Endovascular occlusion of experimental aneurysms with detachable coils: influence of packing density and perioperative anticoagulation. Neurosurgery 1997;41:1160-65; discussion 1165-1168 (Pubitemid 27475479)
    • (1997) Neurosurgery , vol.41 , Issue.5 , pp. 1160-1168
    • Reul, J.1    Spetzger, U.2    Weis, J.3    Sure, U.4    Gilsbach, J.M.5    Thron, A.6
  • 19
    • 24344467495 scopus 로고    scopus 로고
    • Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil
    • Ding YH, Dai D, Lewis DA, et al. Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and Hydro-Coil. AJNR Am J Neuroradiol 2005;26:1757-1763 (Pubitemid 43853676)
    • (2005) American Journal of Neuroradiology , vol.26 , Issue.7 , pp. 1757-1763
    • Ding, Y.H.1    Dai, D.2    Lewis, D.A.3    Cloft, H.J.4    Kallmes, D.F.5
  • 20
    • 0036678056 scopus 로고    scopus 로고
    • Healing response in elastase-induced rabbit aneurysms after embolization with a new platinum coil system
    • Fujiwara NH, Kallmes DF. Healing response in elastase-induced rabbit aneurysms after embolization with a new platinum coil system. AJNR Am J Neuroradiol 2002;23:1137-1144
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1137-1144
    • Fujiwara, N.H.1    Kallmes, D.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.