Volumn 32, Issue 4, 2009, Pages 432-437

Three-step needle withdrawal method: A modified technique for reducing the rate of pneumothorax after CT-guided lung biopsy

Author keywords

Biopsy complications; Computed tomography; Lung biopsy; Pneumothorax; Technology

Indexed keywords

ADULT; AGED; ARTICLE; CAUSE OF DEATH; CHRONIC INFLAMMATION; COMPUTER ASSISTED TOMOGRAPHY; EMPHYSEMA; FEMALE; HUMAN; INFECTION; LUNG BIOPSY; LUNG CANCER; LUNG LESION; LUNG TUBERCULOSIS; MAJOR CLINICAL STUDY; MALE; NEEDLE; PNEUMOTHORAX; RISK FACTOR; TUBE;

EID: 70349191556     PISSN: 20720939     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (20)
  • 2
    • 0025324874 scopus 로고
    • Usefulness of the blood patch technique after transthoracic needle aspiration biopsy
    • Herman SJ, Weisbrod GL. Usefulness of the blood patch technique after transthoracic needle aspiration biopsy. Radiology 1990;176:395-397 (Pubitemid 20225126)
    • (1990) Radiology , vol.176 , Issue.2 , pp. 395-397
    • Herman, S.J.1    Weisbrod, G.L.2
  • 3
    • 0028324956 scopus 로고
    • Mediastinal masses: Alternative approaches to CT-guided needle biopsy
    • Bressler EL, Kirkham JA. Mediastinal masses: alternative approaches to CT-guided needle biopsy. Radiology 1994;191:391-396 (Pubitemid 24141038)
    • (1994) Radiology , vol.191 , Issue.2 , pp. 391-396
    • Bressler, E.L.1    Kirkham, J.A.2
  • 4
    • 0021997060 scopus 로고
    • Transthoracic needle aspiration biopsy of benign and malignant lung lesions
    • Khouri NF, Stitik FP, Erozan YS, Gupta PK, Kim WS, Scott WW Jr, Hamper UM, Mann RB, Eggleston JC, Baker RR. Transthoracic needle aspiration biopsy of benign and malignant lung lesions. AJR Am J Roentgenol 1985;144:281-288 (Pubitemid 15168328)
    • (1985) American Journal of Roentgenology , vol.144 , Issue.2 , pp. 281-288
    • Khouri, N.F.1    Stitik, F.P.2    Erozan, Y.S.3
  • 5
    • 0035167576 scopus 로고    scopus 로고
    • Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions
    • Yeow KM, See LC, Lui KW, Lin MC, Tsao TC, Ng KF, Liu HP. Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions. J Vasc Interv Radiol 2001;12:1305-1312
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 1305-1312
    • Yeow, K.M.1    See, L.C.2    Lui, K.W.3    Lin, M.C.4    Tsao, T.C.5    Ng, K.F.6    Liu, H.P.7
  • 6
    • 4544366568 scopus 로고    scopus 로고
    • Risk factors of pneumothorax and bleeding: Multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies
    • Yeow KM, Su IH, Pan KT, Tsay PK, Lui KW, Cheung YC, Chou SB. Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 2004;126:748-754
    • (2004) Chest , vol.126 , pp. 748-754
    • Yeow, K.M.1    Su, I.H.2    Pan, K.T.3    Tsay, P.K.4    Lui, K.W.5    Cheung, Y.C.6    Chou, S.B.7
  • 7
    • 0033041451 scopus 로고    scopus 로고
    • Transthoracic needle aspiration biopsy: Variables that affect risk of pneumothorax
    • Cox JE, Chiles C, McManus CM, Aquino SL, Choplin RH. Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax. Radiology 1999;212:165-168 (Pubitemid 29302530)
    • (1999) Radiology , vol.212 , Issue.1 , pp. 165-168
    • Cox, J.E.1    Chiles, C.2    McManus, C.M.3    Aquino, S.L.4    Choplin, R.H.5
  • 9
    • 0034523283 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: Results with an automated 20-gauge coaxial cutting needle
    • DOI 10.1053/crad.1999.0368
    • Laurent F, Latrabe V, Vergier B. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with automated 20-gauge coaxial cutting needle. Clin Radiol 2000;55:281-287 (Pubitemid 32054514)
    • (2000) Clinical Radiology , vol.55 , Issue.4 , pp. 281-287
    • Laurent, F.1    Latrabe, V.2    Vergier, B.3    Montaudon, M.4    Vernejoux, J.-M.5    Dubrez, J.6
  • 10
    • 70349189631 scopus 로고    scopus 로고
    • CT-guided cutting needle lung biopsy using modified coaxial technique: Factors effecting risk of complications
    • in press
    • Yildirim E, Kirbas I, Harman A, Ozyer U, Tore HG, Aytekin C, Boyvat F. CT-guided cutting needle lung biopsy using modified coaxial technique: factors effecting risk of complications. Eur J Radiol 2008 (in press).
    • (2008) Eur J Radiol
    • Yildirim, E.1    Kirbas, I.2    Harman, A.3    Ozyer, U.4    Tore, H.G.5    Aytekin, C.6    Boyvat, F.7
  • 11
    • 0035140373 scopus 로고    scopus 로고
    • Factors influencing pneumothorax rate at lung biopsy: Are dwell time and angle of pleural puncture contributing factors?
    • Ko JP, Shepard JO, Drucker EA, Aquino SL, Sharma A, Sabloff B, Halpern E, McLoud TC. Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiology 2001;218:491-496
    • (2001) Radiology , vol.218 , pp. 491-496
    • Ko, J.P.1    Shepard, J.O.2    Drucker, E.A.3    Aquino, S.L.4    Sharma, A.5    Sabloff, B.6    Halpern, E.7    McLoud, T.C.8
  • 12
    • 0030063957 scopus 로고    scopus 로고
    • Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung
    • Kazerooni EA, Lim FT, Mikhail A, Martinez FJ. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 1996;198:371-375 (Pubitemid 26036839)
    • (1996) Radiology , vol.198 , Issue.2 , pp. 371-375
    • Kazerooni, E.A.1    Lim, F.T.2    Mikhail, A.3    Martinez, F.J.4
  • 13
    • 0344925603 scopus 로고    scopus 로고
    • Transthoracic needle biopsy: Factors effecting risk of pneumothorax
    • DOI 10.1016/S0720-048X(03)00058-5
    • Topal U, Ediz B. Transthoracic needle biopsy: factors effecting risk of pneumothorax. Eur J Radiol 2003;48:263-267 (Pubitemid 37491064)
    • (2003) European Journal of Radiology , vol.48 , Issue.3 , pp. 263-267
    • Topal, U.1    Ediz, B.2
  • 14
    • 0031877298 scopus 로고    scopus 로고
    • Technical aspects of needle aspiration lung biopsy: A personal perspective
    • Moore EH. Technical aspects of needle aspiration lung biopsy: a personal perspective. Radiology 1998;208: 30318.
    • (1998) Radiology , vol.208 , pp. 30318
    • Moore, E.H.1
  • 16
    • 0036715050 scopus 로고    scopus 로고
    • Percutaneous lung biopsies: A survey of UK practice based on 5444 biopsies
    • Anderson CL, Pointon KS, Manhire AR, Macfarlane JT. Percutaneous lung biopsies: a survey of UK practice based on 5444 biopsies. Br J Radiol 2002;75:731-735
    • (2002) Br J Radiol , vol.75 , pp. 731-735
    • Anderson, C.L.1    Pointon, K.S.2    Manhire, A.R.3    Macfarlane, J.T.4
  • 17
    • 0142241117 scopus 로고    scopus 로고
    • CT-guided Transthoracic Needle Aspiration Biopsy of Pulmonary Nodules: Needle Size and Pneumothorax Rate
    • DOI 10.1148/radiol.2291020499
    • Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 2003;229:475-481 (Pubitemid 37310835)
    • (2003) Radiology , vol.229 , Issue.2 , pp. 475-481
    • Geraghty, P.R.1    Kee, S.T.2    McFarlane, G.3    Razavi, M.K.4    Sze, D.Y.5    Dake, M.D.6
  • 18
    • 0036182603 scopus 로고    scopus 로고
    • Macroscopic assessment of pulmonary fine needle aspiration biopsies: Correlation with cytological diagnostic yield
    • Williams SW, Gray W, Gleeson FV. Macroscopic assessment of pulmonary fine needle aspirate biopsies: correlation with cytological diagnostic yield. Br J Radiol 2002;75:28-30. (Pubitemid 34168318)
    • (2002) British Journal of Radiology , vol.75 , Issue.889 , pp. 28-30
    • Williams, S.M.1    Gray, W.2    Gleeson, F.V.3
  • 19
    • 0023521038 scopus 로고
    • Transthoracic needle biopsy of lung in nonhospitalized patients
    • Poe RH, Kallay MC. Transthoracic needle biopsy of lung in non-hospitalized patients. Chest 1987;92:676-678 (Pubitemid 18000570)
    • (1987) Chest , vol.92 , Issue.4 , pp. 676-678
    • Poe, R.H.1    Kallay, M.C.2