메뉴 건너뛰기




Volumn , Issue , 2009, Pages 125-130

Passive, transformerless coupling circuitry for narrow-band power-line communications

Author keywords

Coupling circuits; Filters; Impedance adaptation; Passive components

Indexed keywords

COMMUNICATION CIRCUITRY; COUPLING TRANSFORMERS; ELECTRONIC CIRCUITS; FILTER CIRCUITS; FILTERS; IMPEDANCE ADAPTATION; NARROW BANDS; PASSIVE COMPONENTS; PASSIVE COUPLING; PLC TECHNOLOGY; POWER LINES; POWER-LINE COMMUNICATIONS; POWERLINE NETWORKS; TIME SPENT; TRANSFORMERLESS;

EID: 70349154258     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISPLC.2009.4913416     Document Type: Conference Paper
Times cited : (28)

References (10)
  • 1
    • 12544251113 scopus 로고    scopus 로고
    • Design of a bidirectional impedance-adapting transformer coupling circuit for low-voltage power-line communications
    • January
    • P. A. Janse van Rensburg, H. C. Ferreira, "Design of a bidirectional impedance-adapting transformer coupling circuit for low-voltage power-line communications," IEEE Transactions on Power Delivery, vol.20, no.1, January 2005, pp. 64-70.
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.1 , pp. 64-70
    • Janse Van Rensburg, P.A.1    Ferreira, H.C.2
  • 2
    • 37749032062 scopus 로고    scopus 로고
    • Coupler winding ratio selection for effective narrow-band power-line communications
    • January
    • P. A. Janse van Rensburg, H. C. Ferreira, "Coupler winding ratio selection for effective narrow-band power-line communications," IEEE Transactions on Power Delivery, vol.23, no.1, January 2008, pp. 140-149.
    • (2008) IEEE Transactions on Power Delivery , vol.23 , Issue.1 , pp. 140-149
    • Janse Van Rensburg, P.A.1    Ferreira, H.C.2
  • 5
    • 70349151461 scopus 로고
    • Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148.5 kHz
    • Signalling on Low-Voltage Electrical Installations in the Frequency Range 3 kHz to 148.5 kHz, CENELEC Std. EN 50065-50071, 1991.
    • (1991) CENELEC Std. en 50065-1
  • 9
    • 0003559814 scopus 로고    scopus 로고
    • Englewood Cliffs, NJ: Prentice-Hall, 241, 268
    • K. Dostert, Powerline Communications, Englewood Cliffs, NJ: Prentice-Hall, 2001, pp. 92, 241, 268.
    • (2001) Powerline Communications , pp. 92
    • Dostert, K.1
  • 10
    • 0024011930 scopus 로고
    • High frequency noise power spectrum, impedance and transmission loss of power line in Japan on intrabuilding power line communications
    • May
    • M. Tanaka, "High frequency noise power spectrum, impedance and transmission loss of power line in Japan on intrabuilding power line communications," IEEE Trans. Consumer. Electr., vol.CE-34, pp. 321-326, May 1988.
    • (1988) IEEE Trans. Consumer. Electr. , vol.CE-34 , pp. 321-326
    • Tanaka, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.