Volumn 55, Issue 5, 2009, Pages 474-477

Retrospective analysis of 99 patients with the application of extracorporeal membrane oxygenation in Fuwai hospital

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVATED CLOTTING TIME; BLOOD FLOW; CARDIAC SURGERY; DISCHARGE RATES; EQUIPMENT SYSTEM; EXTRACORPOREAL MEMBRANE OXYGENATION; IRREVERSIBLE DAMAGE; KEYPOINTS; POSTOPERATIVE COMPLICATIONS; RETROSPECTIVE ANALYSIS;

EID: 70349113534     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e3181aed564     Document Type: Article
Times cited : (5)

References (18)
  • 1
    • 41149160091 scopus 로고    scopus 로고
    • Neonatal extra-corporeal life support: Indications and limitations
    • Brown KL, Goldman AP: Neonatal extra-corporeal life support: Indications and limitations. Early Hum Dev 84: 143-148, 2008.
    • (2008) Early Hum Dev , vol.84 , pp. 143-148
    • Brown, K.L.1    Goldman, A.P.2
  • 2
    • 47549091610 scopus 로고    scopus 로고
    • Extracorporeal membrane oxygenation: Current clinical practice, coding, and reimbursement
    • Schuerer DJ, Kolovos NS, Boyd KV, et al.: Extracorporeal membrane oxygenation: Current clinical practice, coding, and reimbursement. Chest 134: 179-184, 2008.
    • (2008) Chest , vol.134 , pp. 179-184
    • Schuerer, D.J.1    Kolovos, N.S.2    Boyd, K.V.3
  • 3
    • 26444587194 scopus 로고    scopus 로고
    • Experience with extracorporeal life support in pediatric patients after cardiac surgery
    • Huang SC, Wu ET, Chen YS, et al.: Experience with extracorporeal life support in pediatric patients after cardiac surgery. ASAIO J 51: 517-521, 2005.
    • (2005) ASAIO J , vol.51 , pp. 517-521
    • Huang, S.C.1    Wu, E.T.2    Chen, Y.S.3
  • 4
    • 33746439489 scopus 로고    scopus 로고
    • Can the outcome of pediatric extracorporeal membrane oxygenation after cardiac surgery be predicted?
    • Baslaim G, Bashore J, Al-Malki F, et al.: Can the outcome of pediatric extracorporeal membrane oxygenation after cardiac surgery be predicted? Ann Thorac Cardiovasc Surg 12: 21-27, 2006.
    • (2006) Ann Thorac Cardiovasc Surg , vol.12 , pp. 21-27
    • Baslaim, G.1    Bashore, J.2    Al-Malki, F.3
  • 5
    • 26444487415 scopus 로고    scopus 로고
    • Postoperative extracorporeal life support in pediatric cardiac surgery: Recent results
    • Ghez O, Feier H, Ughetto F, et al.: Postoperative extracorporeal life support in pediatric cardiac surgery: Recent results. ASAIO J 51: 513-516, 2005.
    • (2005) ASAIO J , vol.51 , pp. 513-516
    • Ghez, O.1    Feier, H.2    Ughetto, F.3
  • 6
    • 10744232940 scopus 로고    scopus 로고
    • The waiting game: Bridging to paediatric heart transplantation
    • Goldman AP, Cassidy J, de Leval M, et al.: The waiting game: Bridging to paediatric heart transplantation. Lancet 362: 1967- 1970, 2003.
    • (2003) Lancet , vol.362 , pp. 1967-1970
    • Goldman, A.P.1    Cassidy, J.2    De Leval, M.3
  • 7
    • 0034855775 scopus 로고    scopus 로고
    • Mechanical circulatory support for the treatment of children with acute fulminant myocarditis
    • Duncan BW, Bhon DJ, Alz AM, et al.: Mechanical circulatory support for the treatment of children with acute fulminant myocarditis. J Thorac Cardiovac Surg 122: 440-448, 2001.
    • (2001) J Thorac Cardiovac Surg , vol.122 , pp. 440-448
    • Duncan, B.W.1    Bhon, D.J.2    Alz, A.M.3
  • 8
    • 0036743140 scopus 로고    scopus 로고
    • Use of plasma lactate to predict early mortality and adverse outcome after neonatal extracorporeal membrane oxygenation: A prospective cohort in early childhood
    • Cheung PY, Etches PC, Weardon M, et al.: Use of plasma lactate to predict early mortality and adverse outcome after neonatal extracorporeal membrane oxygenation: A prospective cohort in early childhood. Crit Care Med 30: 2135-2139, 2002.
    • (2002) Crit Care Med , vol.30 , pp. 2135-2139
    • Cheung, P.Y.1    Etches, P.C.2    Weardon, M.3
  • 9
    • 26444440496 scopus 로고    scopus 로고
    • Clinical outcomes of 84 children with congenital heart disease managed with extracorporeal membrane oxygenation after cardiac surgery
    • Shah SA, V Shankar, Kevin B, et al.: Clinical outcomes of 84 children with congenital heart disease managed with extracorporeal membrane oxygenation after cardiac surgery. ASAIO J 51: 504-507, 2005.
    • (2005) ASAIO J , vol.51 , pp. 504-507
    • Shah, S.A.1    Shankar, V.2    Kevin, B.3
  • 10
    • 12844258855 scopus 로고    scopus 로고
    • Extracorporeal life support registry report 2004
    • Conrad SA, Rycus PT, Dalton HJ, et al.: Extracorporeal life support registry report 2004. ASAIO J 51: 4-10, 2005.
    • (2005) ASAIO J , vol.51 , pp. 4-10
    • Conrad, S.A.1    Rycus, P.T.2    Dalton, H.J.3
  • 11
    • 1642482571 scopus 로고    scopus 로고
    • Five-Year results of 219 consecutive patients treated with extracorporeal membrane oxygenation for refractory postoperative cardiogenic shock
    • DOI 10.1016/S0003-4975(03)01329-8
    • Doll N, Kiaii B, Borger M, et al.: Five-year results of 219 consecutive patients treated with extracorporeal membrane oxygenation for refractory postoperative cardiogenic shock. Ann Thorac Surg 77: 151-157, 2004. (Pubitemid 38130002)
    • (2004) Annals of Thoracic Surgery , vol.77 , Issue.1 , pp. 151-157
    • Doll, N.1    Kiaii, B.2    Borger, M.3    Bucerius, J.4    Kramer, K.5    Schmitt, D.V.6    Walther, T.7    Mohr, F.W.8
  • 12
    • 33646193532 scopus 로고    scopus 로고
    • Extracorporeal life support after staged palliation of a functional single ventricle: Subsequent morbidity and survival
    • Hoskote A, Bohn D, Gruenwald C, et al.: Extracorporeal life support after staged palliation of a functional single ventricle: Subsequent morbidity and survival. J Thorac Cardiovasc Surg 131: 1114-1121, 2006.
    • (2006) J Thorac Cardiovasc Surg , vol.131 , pp. 1114-1121
    • Hoskote, A.1    Bohn, D.2    Gruenwald, C.3
  • 13
    • 15344348062 scopus 로고    scopus 로고
    • Plasma leakage of oxygenators in ECMO depends on the type of oxygenator and on patient variables
    • Meyns B, Vercaemst L, Vandezande E, et al.: Plasma leakage of oxygenators in ECMO depends on the type of oxygenator and on patient variables. Int J Artif Organs 28: 30-34, 2005.
    • (2005) Int J Artif Organs , vol.28 , pp. 30-34
    • Meyns, B.1    Vercaemst, L.2    Vandezande, E.3
  • 14
    • 4544292362 scopus 로고    scopus 로고
    • Evaluation of plasma resistant hollow fiber membranes for artificial lungs
    • Eash HJ, Jones HM, Hattler BG, et al.: Evaluation of plasma resistant hollow fiber membranes for artificial lungs. ASAIO J 50: 491-497, 2004.
    • (2004) ASAIO J , vol.50 , pp. 491-497
    • Eash, H.J.1    Jones, H.M.2    Hattler, B.G.3
  • 15
    • 4444226266 scopus 로고    scopus 로고
    • Compact intra- and extracorporeal oxygenator developments
    • Cattaneo G, Strauss A, Reul H, et al.: Compact intra- and extracorporeal oxygenator developments. Perfusion 19: 251-255, 2004.
    • (2004) Perfusion , vol.19 , pp. 251-255
    • Cattaneo, G.1    Strauss, A.2    Reul, H.3
  • 16
    • 0036289469 scopus 로고    scopus 로고
    • Use of assist devices and ECMO to bridge pediatric patients with cardiomyopathy to transplantation
    • Levi D, Marelli D, Plunkett M, et al.: Use of assist devices and ECMO to bridge pediatric patients with cardiomyopathy to transplantation. J Heart Lung Transplant 21: 760-770, 2002.
    • (2002) J Heart Lung Transplant , vol.21 , pp. 760-770
    • Levi, D.1    Marelli, D.2    Plunkett, M.3
  • 17
    • 0036016597 scopus 로고    scopus 로고
    • At least thirty-four days of animal continuous perfusion by a newly developed extracorporeal membrane oxygenation system without systemic anticoagulants
    • Nishinaka T, Tatsumi E, Taenaka Y, et al.: At least thirty-four days of animal continuous perfusion by a newly developed extracorporeal membrane oxygenation system without systemic anticoagulants. Artif Organs 26: 548-551, 2002.
    • (2002) Artif Organs , vol.26 , pp. 548-551
    • Nishinaka, T.1    Tatsumi, E.2    Taenaka, Y.3
  • 18
    • 10744224311 scopus 로고    scopus 로고
    • Development of silicone rubber hollow fiber membrane oxygenator for ECMO
    • Motomura T, Maeda T, Kawahito S, et al.: Development of silicone rubber hollow fiber membrane oxygenator for ECMO. Artif Organs 27: 1050-1053, 2003.
    • (2003) Artif Organs , vol.27 , pp. 1050-1053
    • Motomura, T.1    Maeda, T.2    Kawahito, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.