메뉴 건너뛰기




Volumn 252, Issue 2, 2009, Pages 568-576

Measurement of hepatic lipid: High-speed T2-corrected multiecho acquisition at 1H MR spectroscopy - A rapid and accurate technique

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADOLESCENT; ADULT; AGED; ARTICLE; CHILD; CLINICAL ARTICLE; HUMAN; LIPID LIVER LEVEL; LIVER; MALE; MEASUREMENT; PHANTOM; PRIORITY JOURNAL; PROTON NUCLEAR MAGNETIC RESONANCE; REPRODUCIBILITY; ALGORITHM; FATTY LIVER; IMAGE QUALITY; INSTRUMENTATION; METABOLISM; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; SENSITIVITY AND SPECIFICITY;

EID: 70249092550     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.2523082084     Document Type: Article
Times cited : (133)

References (27)
  • 1
    • 33749997529 scopus 로고    scopus 로고
    • Pediatric nonalcoholic fatty liver disease: A critical appraisal of current data and implications for future research
    • DOI 10.1097/01.mpg.0000239995.58388.56, PII 0000517620061000000003
    • Patton HM, Sirlin C, Behling C, Middleton M, Schwimmer JB, Lavine JE. Pediatric nonalcoholic fatty liver disease: a critical appraisal of current data and implications for future research. J Pediatr Gastroenterol Nutr 2006;43(4):413-427. (Pubitemid 44568999)
    • (2006) Journal of Pediatric Gastroenterology and Nutrition , vol.43 , Issue.4 , pp. 413-427
    • Patton, H.M.1    Sirlin, C.2    Behling, C.3    Middleton, M.4    Schwimmer, J.B.5    Lavine, J.E.6
  • 2
    • 33750002388 scopus 로고    scopus 로고
    • Prevalence of fatty liver in children and adolescents
    • DOI 10.1542/peds.2006-1212
    • Schwimmer JB, Deutsch R, Kahen T, Lavine JE, Stanley C, Behling C. Prevalence of fatty liver in children and adolescents. Pediatrics 2006;118(4):1388-1393. (Pubitemid 46393782)
    • (2006) Pediatrics , vol.118 , Issue.4 , pp. 1388-1393
    • Schwimmer, J.B.1    Deutsch, R.2    Kahen, T.3    Lavine, J.E.4    Stanley, C.5    Behling, C.6
  • 3
    • 0037920345 scopus 로고    scopus 로고
    • The spectrum of fatty liver in obese children and the relationship of serum aminotransferases to severity of steatosis
    • DOI 10.1097/00005176-200301000-00012
    • Fishbein MH, Miner M, Mogren C, Chalekson J. The spectrum of fatty liver in obese children and the relationship of serum aminotransferases to severity of steatosis. J Pediatr Gastroenterol Nutr 2003;36(1):54-61. (Pubitemid 41672620)
    • (2003) Journal of Pediatric Gastroenterology and Nutrition , vol.36 , Issue.1 , pp. 54-61
    • Fishbein, M.H.1    Miner, M.2    Mogren, C.3    Chalekson, J.4
  • 4
    • 33747596229 scopus 로고    scopus 로고
    • Non-alcoholic fatty liver disease in obese children evaluated by magnetic resonance imaging
    • Radetti G, Kleon W, Stuefer J, Pittschieler K. Non-alcoholic fatty liver disease in obese children evaluated by magnetic resonance imaging. Acta Paediatr 2006;95(7):833-837.
    • (2006) Acta Paediatr , vol.95 , Issue.7 , pp. 833-837
    • Radetti, G.1    Kleon, W.2    Stuefer, J.3    Pittschieler, K.4
  • 5
    • 33645828659 scopus 로고    scopus 로고
    • Lipid metabolism and liver inflammation. II. Fatty liver disease and fatty acid oxidation
    • Reddy JK, Rao MS. Lipid metabolism and liver inflammation. II. Fatty liver disease and fatty acid oxidation. Am J Physiol Gastrointest Liver Physiol 2006;290(5):G852-G858.
    • (2006) Am J Physiol Gastrointest Liver Physiol , vol.290 , Issue.5
    • Reddy, J.K.1    Rao, M.S.2
  • 6
    • 0036199279 scopus 로고    scopus 로고
    • Evaluation of iron overload by single voxel MRS measurement of liver T2
    • Wang ZJ, Haselgrove JC, Martin MB. Evaluation of iron overload by single voxel MRS measurement of liver T2. J Magn Reson Imaging 2002;15(5):395-400.
    • (2002) J Magn Reson Imaging , vol.15 , Issue.5 , pp. 395-400
    • Wang, Z.J.1    Haselgrove, J.C.2    Martin, M.B.3
  • 8
    • 0030995737 scopus 로고    scopus 로고
    • Introduction of fast MR imaging in the assessment of hepatic steatosis
    • DOI 10.1016/S0730-725X(96)00224-X, PII S0730725X96002247
    • Fishbein MH, Gardner KG, Potter CJ, Schmalbrock P, Smith MA. Introduction of fast MR imaging in the assessment of hepatic steatosis. Magn Reson Imaging 1997;15(3):287-293. (Pubitemid 27280484)
    • (1997) Magnetic Resonance Imaging , vol.15 , Issue.3 , pp. 287-293
    • Fishbein, M.H.1    Gardner, K.G.2    Potter, C.J.3    Schmalbrock, P.4    Smith, M.A.5
  • 9
    • 33748443187 scopus 로고    scopus 로고
    • Low-carbohydrate diet induced reduction of hepatic lipid content observed with a rapid non-invasive MRI technique
    • DOI 10.1259/bjr/23166141
    • Hollingsworth KG, Abubacker MZ, Joubert I, Allison ME, Lomas DJ. Low-carbohydrate diet induced reduction of hepatic lipid content observed with a rapid non-invasive MRI technique. Br J Radiol 2006;79(945):712-715. (Pubitemid 44349511)
    • (2006) British Journal of Radiology , vol.79 , Issue.945 , pp. 712-715
    • Hollingsworth, K.G.1    Abubacker, M.Z.2    Joubert, I.3    Allison, M.E.D.4    Lomas, D.J.5
  • 11
    • 33749487086 scopus 로고    scopus 로고
    • Measurement of liver fat by magnetic resonance imaging: Relationships with body fat distribution, insulin sensitivity and plasma lipids in healthy men
    • DOI 10.1111/j.1463-1326.2005.00543.x
    • Chan DC, Watts GF, Ng TW, Hua J, Song S, Barrett PH. Measurement of liver fat by magnetic resonance imaging: relationship with body fat distribution, insulin sensitivity and plasma lipids in healthy men. Diabetes Obes Metab 2006;8(6):698-702. (Pubitemid 44515568)
    • (2006) Diabetes, Obesity and Metabolism , vol.8 , Issue.6 , pp. 698-702
    • Chan, D.C.1    Watts, G.F.2    Ng, T.W.K.3    Hua, J.4    Song, S.5    Barrett, P.H.R.6
  • 12
    • 0033007207 scopus 로고    scopus 로고
    • Measurement of intracellular triglyceride stores by 1H spectroscopy: Validation in vivo
    • Szczepaniak LS, Babcock EE, Schick F, et al. Measurement of intracellular triglyceride stores by 1H spectroscopy: validation in vivo. Am J Physiol Endocrinol Metab 1999;276:E977-E989.
    • (1999) Am J Physiol Endocrinol Metab , vol.276
    • Szczepaniak, L.S.1    Babcock, E.E.2    Schick, F.3
  • 14
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon WT. Simple proton spectroscopic imaging. Radiology 1984;153(1):189-194.
    • (1984) Radiology , vol.153 , Issue.1 , pp. 189-194
    • Dixon, W.T.1
  • 15
    • 0034761279 scopus 로고    scopus 로고
    • Rapid MRI using a modified Dixon technique: A non-invasive and effective method for the detection and monitoring of fatty metamorphosis of the liver
    • Fishbein MH, Stevens WR. Rapid MRI using a modified Dixon technique: a non-invasive and effective method for the detection and monitoring of fatty metamorphosis of the liver. Pediatr Radiol 2001;31(11):806-809.
    • (2001) Pediatr Radiol , vol.31 , Issue.11 , pp. 806-809
    • Fishbein, M.H.1    Stevens, W.R.2
  • 16
    • 0025831477 scopus 로고
    • Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction
    • Glover GH, Schneider E. Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction. Magn Reson Med 1991;18(2):371-383.
    • (1991) Magn Reson Med , vol.18 , Issue.2 , pp. 371-383
    • Glover, G.H.1    Schneider, E.2
  • 17
    • 0026216918 scopus 로고
    • Multipoint Dixon technique for water and fat proton and susceptibility imaging
    • Glover GH. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991;1(5):521-530.
    • (1991) J Magn Reson Imaging , vol.1 , Issue.5 , pp. 521-530
    • Glover, G.H.1
  • 19
    • 10844240700 scopus 로고    scopus 로고
    • Hepatic triglyceride content and its relation to body adiposity: A magnetic resonance imaging and proton magnetic resonance spectroscopy study
    • DOI 10.1136/gut.2003.036566
    • Thomas EL, Hamilton G, Patel N, et al. Hepatic triglyceride content and its relation to body adiposity: a magnetic resonance imaging and proton magnetic resonance spectroscopy study. Gut 2005;54(1):122-127. (Pubitemid 40007230)
    • (2005) Gut , vol.54 , Issue.1 , pp. 122-127
    • Thomas, E.L.1    Hamilton, G.2    Patel, N.3    O'Dwyer, R.4    Dore, C.J.5    Goldin, R.D.6    Bell, J.D.7    Taylor-Robinson, S.D.8
  • 21
    • 33645786275 scopus 로고    scopus 로고
    • Hepatic lipid accumulation in healthy subjects: A comparative study using spectral fat-selective MRI and volume-localized 1H-MR spectroscopy
    • Machann J, Thamer C, Schnoedt B, et al. Hepatic lipid accumulation in healthy subjects: a comparative study using spectral fat-selective MRI and volume-localized 1H-MR spectroscopy. Magn Reson Med 2006;55(4):913-917.
    • (2006) Magn Reson Med , vol.55 , Issue.4 , pp. 913-917
    • Machann, J.1    Thamer, C.2    Schnoedt, B.3
  • 22
    • 44449167605 scopus 로고    scopus 로고
    • Liver fat content and T2*: Simultaneous measurement by using breath-hold multiecho MR imaging at 3.0 T-feasibility
    • O'Regan DP, Callaghan MF, Wylezinska-Arridge M, et al. Liver fat content and T2*: simultaneous measurement by using breath-hold multiecho MR imaging at 3.0 T-feasibility. Radiology 2008;247(2):550-557.
    • (2008) Radiology , vol.247 , Issue.2 , pp. 550-557
    • O'Regan, D.P.1    Callaghan, M.F.2    Wylezinska-Arridge, M.3
  • 23
    • 0000927648 scopus 로고    scopus 로고
    • Quantitative localized (1)H MR spectroscopy for clinical use
    • Kreis R. Quantitative localized (1)H MR spectroscopy for clinical use. J Prog NMR 1997;31:155-195.
    • (1997) J Prog NMR , vol.31 , pp. 155-195
    • Kreis, R.1
  • 24
    • 0034959727 scopus 로고    scopus 로고
    • Automatic quantitation of localized in vivo 1H spectra with LCModel
    • Provencher SW. Automatic quantitation of localized in vivo 1H spectra with LCModel. NMR Biomed 2001;14(4):260-264.
    • (2001) NMR Biomed , vol.14 , Issue.4 , pp. 260-264
    • Provencher, S.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.