Biodegradable Mg for bone implants: Corrosion and osteoblast culture studies

Author keywords

Biodegradable implant; Corrosion; Magnesium; U2OS cells

Indexed keywords

CELL CULTURE; CELLS; DEIONIZED WATER; ELECTROCHEMICAL CORROSION; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ENERGY DISPERSIVE X RAY ANALYSIS; MAGNESIUM COMPOUNDS; POTASSIUM CHLORIDE;

EID: 70149097290     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1115/IMECE2008-69224     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 2
    • 0037026403 scopus 로고    scopus 로고
    • Initial interaction of U2OS cells with noncoated and calcium phosphate coated titanium substrates
    • Brugge, P. J., Dieudonne, S., Jansen, J. A., Initial interaction of U2OS cells with noncoated and calcium phosphate coated titanium substrates. Journal of Biomedical Materials Research, 2002. 61(3): p. 399-407.
    • (2002) Journal of Biomedical Materials Research , vol.61 , Issue.3 , pp. 399-407
    • Brugge, P.J.1    Dieudonne, S.2    Jansen, J.A.3
  • 3
    • 28844481103 scopus 로고    scopus 로고
    • Mg and its alloys as orthopedic biomaterials: A review
    • Staiger, M. P., and Pietak, A. M., Mg and its alloys as orthopedic biomaterials: A review. Biomaterials, 2006. 27: p. 1728-1734.
    • (2006) Biomaterials , vol.27 , pp. 1728-1734
    • Staiger, M.P.1    Pietak, A.M.2
  • 4
    • 41949102580 scopus 로고    scopus 로고
    • Biocompatibility: Meeting a key functional requirement of next-generation medical devices
    • Helmus, M. N., Gibbons, D. F., and Cebon, D., Biocompatibility: meeting a key functional requirement of next-generation medical devices. Toxicologic Pathology, 2008. 36: p. 70-80.
    • (2008) Toxicologic Pathology , vol.36 , pp. 70-80
    • Helmus, M.N.1    Gibbons, D.F.2    Cebon, D.3
  • 5
    • 38349153562 scopus 로고    scopus 로고
    • The development of binary Mg-Ca alloys for use as biodegradable materials within bone
    • Li, Z., Gu, X., Lou, S., and Zheng, Y., The development of binary Mg-Ca alloys for use as biodegradable materials within bone. Biomaterials, 2008. 29: p. 1329-1344.
    • (2008) Biomaterials , vol.29 , pp. 1329-1344
    • Li, Z.1    Gu, X.2    Lou, S.3    Zheng, Y.4
  • 6
    • 40149103265 scopus 로고    scopus 로고
    • In vitro corrosion behaviour of Mg alloys in a phosphate buffered solution for bone implant application
    • Xu, L., Zhang, E., Yin, D., Zeng, S., and Yang, K., In vitro corrosion behaviour of Mg alloys in a phosphate buffered solution for bone implant application. Journal of materials science, 2008. 19: p. 1017-1025.
    • (2008) Journal of materials science , vol.19 , pp. 1017-1025
    • Xu, L.1    Zhang, E.2    Yin, D.3    Zeng, S.4    Yang, K.5
  • 7
    • 35549006316 scopus 로고    scopus 로고
    • Characterization and corrosion studies of fluoride conversion coating on degradable Mg implants
    • Chiu, K.Y., Wong, M.H., Cheng, F.T., Man, H.C., Characterization and corrosion studies of fluoride conversion coating on degradable Mg implants. Surface and coating technology, 2007. 202: p. 590-598.
    • (2007) Surface and coating technology , vol.202 , pp. 590-598
    • Chiu, K.Y.1    Wong, M.H.2    Cheng, F.T.3    Man, H.C.4
  • 8
    • 34249744766 scopus 로고    scopus 로고
    • Mg and its alloys as degradable biomaterials: Corrosion studies using potentiodynamic and EIS electrochemical techniques
    • Müller, W. D., Nascimento, M. L., Zeddies, M., Córsico, M., Gassa, L. M., Mele, M., Mg and its alloys as degradable biomaterials: corrosion studies using potentiodynamic and EIS electrochemical techniques. Materials Research 2007. 10(1): p. 5-10.
    • (2007) Materials Research , vol.10 , Issue.1 , pp. 5-10
    • Müller, W.D.1    Nascimento, M.L.2    Zeddies, M.3    Córsico, M.4    Gassa, L.M.5    Mele, M.6
  • 9
    • 40449134564 scopus 로고    scopus 로고
    • Time-dependent electrochemical characterization of corrosion of a Mg rare-earth alloy in simulated body fluids
    • Rettig, R. and Virtanen, S., Time-dependent electrochemical characterization of corrosion of a Mg rare-earth alloy in simulated body fluids. Journal of biomedical materials research part A, 2007. 85A(1): p. 167-175.
    • (2007) Journal of biomedical materials research part A , vol.85 A , Issue.1 , pp. 167-175
    • Rettig, R.1    Virtanen, S.2
  • 11
    • 33847621267 scopus 로고    scopus 로고
    • Control of biodegradation of biocompatable Mg alloys
    • Song, G., Control of biodegradation of biocompatable Mg alloys. Corrosion science, 2007. 49: p. 1696-1701.
    • (2007) Corrosion science , vol.49 , pp. 1696-1701
    • Song, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.