메뉴 건너뛰기




Volumn 26, Issue 5, 2009, Pages 416-420

Auditory function after spinal anaesthesia: the effect of differently designed spinal needles

Author keywords

Audiometry; Ballpen spinal needle; Hearing loss; Spinal anaesthesia

Indexed keywords

BUPIVACAINE; EPHEDRINE; MIDAZOLAM;

EID: 70149095367     PISSN: 02650215     EISSN: 13652346     Source Type: Journal    
DOI: 10.1097/EJA.0b013e32831c89d4     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 0020556263 scopus 로고
    • Transient low-frequency hypoacousia after spinal anaesthesia
    • Panning B, Mehler D, Lehnhardt E. Transient low-frequency hypoacousia after spinal anaesthesia. Lancet 1983; 2:582.
    • (1983) Lancet , vol.2 , pp. 582
    • Panning, B.1    Mehler, D.2    Lehnhardt, E.3
  • 2
    • 0022577554 scopus 로고
    • Unilateral hearing loss after spinal anaesthesia treated with epidural blood patch
    • Lee CM, Peachman FA. Unilateral hearing loss after spinal anaesthesia treated with epidural blood patch. Anesth Analg 1986; 65:312.
    • (1986) Anesth Analg , vol.65 , pp. 312
    • Lee, C.M.1    Peachman, F.A.2
  • 3
    • 0025724876 scopus 로고
    • Low frequency hearing loss after spinal anaesthesia: Perilymphatic hypotonia?
    • Walsted A, Salomon G, Olsen KS. Low frequency hearing loss after spinal anaesthesia: perilymphatic hypotonia? Scand Audiol 1991; 20:211 -215.
    • (1991) Scand Audiol , vol.20 , pp. 211-215
    • Walsted, A.1    Salomon, G.2    Olsen, K.S.3
  • 4
    • 0036786341 scopus 로고    scopus 로고
    • Permanent sensorineural hearing loss following spinal anaesthesia
    • Kilickan L, Gurkan Y, Ozkarakas H. Permanent sensorineural hearing loss following spinal anaesthesia. Acta Anaesthesiol Scand 2002; 46:1155-1157.
    • (2002) Acta Anaesthesiol Scand , vol.46 , pp. 1155-1157
    • Kilickan, L.1    Gurkan, Y.2    Ozkarakas, H.3
  • 5
    • 11144237493 scopus 로고    scopus 로고
    • Hearing impairment associated with spinal anaesthesia
    • Cosar A, Yetiser S, Sizlan A, et al. Hearing impairment associated with spinal anaesthesia. Acta Otolaryngol 2004; 124:1159-1164.
    • (2004) Acta Otolaryngol , vol.124 , pp. 1159-1164
    • Cosar, A.1    Yetiser, S.2    Sizlan, A.3
  • 6
    • 0029999015 scopus 로고    scopus 로고
    • Auditory, ocular and facial complications of central neural block: A review of possible mechanisms
    • Day CJE, Shutt LE. Auditory, ocular and facial complications of central neural block: a review of possible mechanisms. Reg Anesth 1996; 21:197-201.
    • (1996) Reg Anesth , vol.21 , pp. 197-201
    • Day, C.J.E.1    Shutt, L.E.2
  • 7
    • 0025025050 scopus 로고
    • Hearing loss after spinal anaesthesia is related to needle size
    • Fog J, Wang LP, Sundberg A, Mucchiano C. Hearing loss after spinal anaesthesia is related to needle size. Anesth Analg 1990; 70:517-522.
    • (1990) Anesth Analg , vol.70 , pp. 517-522
    • Fog, J.1    Wang, L.P.2    Sundberg, A.3    Mucchiano, C.4
  • 8
    • 0023634018 scopus 로고
    • Transient hearing loss following spinal anaesthesia
    • Wang LP, Fog J, Bove M. Transient hearing loss following spinal anaesthesia. Anaesthesia 1987; 42:1258-1263.
    • (1987) Anaesthesia , vol.42 , pp. 1258-1263
    • Wang, L.P.1    Fog, J.2    Bove, M.3
  • 9
    • 0026457709 scopus 로고
    • Influence of hearing of 22 G Whitacre and 22 G Quincke needles
    • Sundberg A, Wang LP, Fog J. Influence of hearing of 22 G Whitacre and 22 G Quincke needles. Anaesthesia 1992; 47:981 -983.
    • (1992) Anaesthesia , vol.47 , pp. 981-983
    • Sundberg, A.1    Wang, L.P.2    Fog, J.3
  • 10
    • 1642459991 scopus 로고    scopus 로고
    • Spinal anaesthesia performance conditions and side effects are comparable between the newly designed Ballpen and the Sprotte needle: Results of a prospective comparative randomized multicenter study
    • Standl T, Stanek A, Burmeister MA, et al. Spinal anaesthesia performance conditions and side effects are comparable between the newly designed Ballpen and the Sprotte needle: results of a prospective comparative randomized multicenter study. Anesth Analg 2004; 98:512-517.
    • (2004) Anesth Analg , vol.98 , pp. 512-517
    • Standl, T.1    Stanek, A.2    Burmeister, M.A.3
  • 11
    • 0021705439 scopus 로고
    • Transient low-frequency hearing loss following spinal anaesthesia
    • Panning B, Lehnhardt E, Mehler D. Transient low-frequency hearing loss following spinal anaesthesia. Anaesthesist 1984; 33:593-595.
    • (1984) Anaesthesist , vol.33 , pp. 593-595
    • Panning, B.1    Lehnhardt, E.2    Mehler, D.3
  • 12
    • 33745943616 scopus 로고    scopus 로고
    • Evaluation of hearing loss after spinal anaesthesia with otoacoustic emissions
    • Karatas E, Göksu S, Durucu C, et al. Evaluation of hearing loss after spinal anaesthesia with otoacoustic emissions. Eur Arch Otorhinolaryngol 2006; 263:705-710.
    • (2006) Eur Arch Otorhinolaryngol , vol.263 , pp. 705-710
    • Karatas, E.1    Göksu, S.2    Durucu, C.3
  • 13
    • 0038547063 scopus 로고    scopus 로고
    • The effect of combined spinal- epidural (CSE) anaesthesia and size of spinal needle on postoperative hearing loss after elective caesarean section
    • Kiliçkan L, Gürkan Y, Aydin O, Etiler N. The effect of combined spinal- epidural (CSE) anaesthesia and size of spinal needle on postoperative hearing loss after elective caesarean section. Clin Otolaryngol Allied Sci 2003; 28:267-272.
    • (2003) Clin Otolaryngol Allied Sci , vol.28 , pp. 267-272
    • Kiliçkan, L.1    Gürkan, Y.2    Aydin, O.3    Etiler, N.4
  • 14
    • 0022535417 scopus 로고
    • Sudden bilateral hearing loss after spinal anaesthesia: A case report
    • Wang LP. Sudden bilateral hearing loss after spinal anaesthesia: a case report. Acta Anaesthesiol Scand 1986; 30:412-413.
    • (1986) Acta Anaesthesiol Scand , vol.30 , pp. 412-413
    • Wang, L.P.1
  • 15
    • 0031839653 scopus 로고    scopus 로고
    • Effects of cerebrospinal fluid loss on the auditory system
    • Walsted A. Effects of cerebrospinal fluid loss on the auditory system. Dan Med Bull 1998; 45:268-281.
    • (1998) Dan Med Bull , vol.45 , pp. 268-281
    • Walsted, A.1
  • 16
    • 0033708805 scopus 로고    scopus 로고
    • Hearing loss after spinal and general anaesthesia: Acomparative study
    • Schaffartzik W, Hirsch J, Frickmann F, et al. Hearing loss after spinal and general anaesthesia: acomparative study.Anesth Analg 2000; 91:1466-1472.
    • (2000) Anesth Analg , vol.91 , pp. 1466-1472
    • Schaffartzik, W.1    Hirsch, J.2    Frickmann, F.3
  • 17
    • 0036288759 scopus 로고    scopus 로고
    • Does spinal anaesthesia cause hearing loss in the obstetric population?
    • Finegold H, Mandell G, Vallejo M, Ramanathan S. Does spinal anaesthesia cause hearing loss in the obstetric population? Anesth Analg 2002; 95:198-203.
    • (2002) Anesth Analg , vol.95 , pp. 198-203
    • Finegold, H.1    Mandell, G.2    Vallejo, M.3    Ramanathan, S.4
  • 18
    • 0026692712 scopus 로고
    • Hearing loss as sequel of lumbar puncture
    • Michel O, Brusis T. Hearing loss as sequel of lumbar puncture. Ann Otol Rhinol Laryngol 1992; 101:390-394.
    • (1992) Ann Otol Rhinol Laryngol , vol.101 , pp. 390-394
    • Michel, O.1    Brusis, T.2
  • 19
    • 0025379378 scopus 로고
    • Inner ear hearing loss following cerebrospinal fluid puncture: A too little appreciated complication?
    • Michel O, Brusis T, Loennecken I, Matthias R. Inner ear hearing loss following cerebrospinal fluid puncture: a too little appreciated complication? HNO 1990; 38:71 -76.
    • (1990) HNO , vol.38 , pp. 71-76
    • Michel, O.1    Brusis, T.2    Loennecken, I.3    Matthias, R.4
  • 20
    • 0036236015 scopus 로고    scopus 로고
    • Does hearing loss after spinal anaesthesia differ between young and elder lypatients?
    • Gültekin S, Ozcan S. Does hearing loss after spinal anaesthesia differ between young and elder lypatients? Anesth Analg 2002;94:1318-1320.
    • (2002) Anesth Analg , vol.94 , pp. 1318-1320
    • Gültekin, S.1    Ozcan, S.2
  • 22
    • 0024789933 scopus 로고
    • Spinal needledeterminantsof rate of transdural fluid leak
    • ReadyLB, Cuplin S, Haschke RH, NesslyM. Spinal needledeterminantsof rate of transdural fluid leak. Anesth Analg 1989; 69:457-460.
    • (1989) Anesth Analg , vol.69 , pp. 457-460
    • Ready, L.B.1    Cuplin, S.2    Haschke, R.H.3    Nessly, M.4
  • 23
    • 0036373536 scopus 로고    scopus 로고
    • Auditory function following spinal analgesia: Comparison of two spinal needles
    • Malhotra SK, Joshi M, Grover S, et al. Auditory function following spinal analgesia: comparison of two spinal needles. Eur J Anaesthesiol 2002; 19:69-72.
    • (2002) Eur J Anaesthesiol , vol.19 , pp. 69-72
    • Malhotra, S.K.1    Joshi, M.2    Grover, S.3
  • 24
    • 4544268152 scopus 로고    scopus 로고
    • Hearing loss does not occur in young patients undergoing spinal anaesthesia
    • Ok G, Tok D, Erbuyun K, et al. Hearing loss does not occur in young patients undergoing spinal anaesthesia. Reg Anesth Pain Med 2004; 29:430-433.
    • (2004) Reg Anesth Pain Med , vol.29 , pp. 430-433
    • Ok, G.1    Tok, D.2    Erbuyun, K.3
  • 25
    • 0030735247 scopus 로고    scopus 로고
    • A microscopic analysis of cut-bevel versus pencil- point spinal needles
    • Parker RK, White PF. A microscopic analysis of cut-bevel versus pencil- point spinal needles. Anesth Analg 1997; 85:1101-1104.
    • (1997) Anesth Analg , vol.85 , pp. 1101-1104
    • Parker, R.K.1    White, P.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.