메뉴 건너뛰기




Volumn 5359 LNCS, Issue PART 2, 2008, Pages 843-850

Visual servoing for patient alignment in protontherapy

Author keywords

[No Author keywords available]

Indexed keywords

6 DOF MANIPULATOR; ERROR FUNCTION; FEATURE POINT; FEATURE VECTORS; FOUR QUADRANT; GREY LEVELS; IMAGE ERROR; IMAGE FEATURES; IMAGE JACOBIAN; IMAGE-BASED; ISOCENTERS; PATIENT DOSE; PATIENT REPOSITIONING; PLASTIC MOULD; PROPORTIONAL CONTROL; PROTON THERAPY; REFERENCE IMAGE;

EID: 70149083921     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-540-89646-3_83     Document Type: Conference Paper
Times cited : (4)

References (17)
  • 2
    • 0038030020 scopus 로고    scopus 로고
    • Quality assurance of a system for improved target localization and patient setup that combines real time infrared tracking and stereoscopic Xray imaging
    • Verellen, D., Soete, G., Linthout, N., Van Acker, S., De Roover, P., Van de Steene, J., Vinh-Hung, V., Storme, G.: Quality assurance of a system for improved target localization and patient setup that combines real time infrared tracking and stereoscopic Xray imaging. Radiotherapy and Oncology 67(5) (2003)
    • (2003) Radiotherapy and Oncology , vol.67 , Issue.5
    • Verellen, D.1    Soete, G.2    Linthout, N.3    Van Acker, S.4    De Roover, P.5    Van de Steene, J.6    Vinh-Hung, V.7    Storme, G.8
  • 6
    • 49049121291 scopus 로고    scopus 로고
    • Respiratory Motion Tracking of Skin and Liver in Swine for CyberKnife Motion Compensation
    • Tanga, J., Dieterichb, S., Clearya, K.: Respiratory Motion Tracking of Skin and Liver in Swine for CyberKnife Motion Compensation. In: SPIE Medical Imaging (2004)
    • (2004) SPIE Medical Imaging
    • Tanga, J.1    Dieterichb, S.2    Clearya, K.3
  • 7
    • 34250335308 scopus 로고    scopus 로고
    • Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax
    • Harms, W., Schoffel, P.J., Sroka-Perez, G., Schlegel, W., Karger, C.P.: Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax. Phys. Med. Biol. 52(5), 3949-3963 (2007)
    • (2007) Phys. Med. Biol , vol.52 , Issue.5 , pp. 3949-3963
    • Harms, W.1    Schoffel, P.J.2    Sroka-Perez, G.3    Schlegel, W.4    Karger, C.P.5
  • 8
    • 33748946194 scopus 로고    scopus 로고
    • Method comparison of ultrasound and kilovolt-age x-ray fiducial marker imaging for prostate radiotherapy targeting
    • Fuller, D.C., Thomas, C.R., Schwartz, S., Golden, N., Ting, J., Wong, A., Erdogmus, D., Scarbrough, T.J.: Method comparison of ultrasound and kilovolt-age x-ray fiducial marker imaging for prostate radiotherapy targeting. Phys. Med. Biol. 51(19), 4981-4993 (2006)
    • (2006) Phys. Med. Biol , vol.51 , Issue.19 , pp. 4981-4993
    • Fuller, D.C.1    Thomas, C.R.2    Schwartz, S.3    Golden, N.4    Ting, J.5    Wong, A.6    Erdogmus, D.7    Scarbrough, T.J.8
  • 11
    • 0026967479 scopus 로고
    • A survey of image registration techniques
    • Brown, L.G.: A survey of image registration techniques. ACM Computing Surveys 24(4), 325-376 (1992)
    • (1992) ACM Computing Surveys , vol.24 , Issue.4 , pp. 325-376
    • Brown, L.G.1
  • 13
    • 2442456044 scopus 로고    scopus 로고
    • Pyramidal Implementation of the Lucas Kanade Feature Tracker: Description of the algorithm
    • Technical report, Intel Corporation Microprocessor Research Labs
    • Bouguet, J.-Y.: Pyramidal Implementation of the Lucas Kanade Feature Tracker: Description of the algorithm. Technical report, Intel Corporation Microprocessor Research Labs (2000)
    • (2000)
    • Bouguet, J.-Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.