메뉴 건너뛰기




Volumn 10, Issue 1, 2009, Pages 71-79

Automated quality assurance for image-guided radiation therapy

Author keywords

CBCT; OBI; QA; Trilogy

Indexed keywords


EID: 70049111589     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v10i1.2919     Document Type: Article
Times cited : (15)

References (7)
  • 1
    • 34247549194 scopus 로고    scopus 로고
    • Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator
    • Saw CB, Yang Y, Li F, et al. Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator. Med Dosim. 2007;32(2):80-85.
    • (2007) Med Dosim , vol.32 , Issue.2 , pp. 80-85
    • Saw, C.B.1    Yang, Y.2    Li, F.3
  • 2
    • 34548863912 scopus 로고    scopus 로고
    • Quality assurance of image-guidance technologies
    • Bissonnette J-P. Quality assurance of image-guidance technologies. Semin Radiat Oncol. 2007;17(4):278-86.
    • (2007) Semin Radiat Oncol , vol.17 , Issue.4 , pp. 278-286
    • Bissonnette, J.-P.1
  • 3
    • 33750568952 scopus 로고    scopus 로고
    • A quality assurance program for the on-board imagers
    • Yoo S, Kim GY, Hammoud R, et al. A quality assurance program for the on-board imagers. Med Phys. 2006;33(11):4431-47.
    • (2006) Med Phys , vol.33 , Issue.11 , pp. 4431-4447
    • Yoo, S.1    Kim, G.Y.2    Hammoud, R.3
  • 4
    • 31044444873 scopus 로고    scopus 로고
    • The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator
    • Sharpe MB, Moseley DJ, Purdie TG, Islam M, Siewerdsen JH, Jaffray DA. The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator. Med Phys. 2006;33(1):136-44.
    • (2006) Med Phys , vol.33 , Issue.1 , pp. 136-144
    • Sharpe, M.B.1    Moseley, D.J.2    Purdie, T.G.3    Islam, M.4    Siewerdsen, J.H.5    Jaffray, D.A.6
  • 5
    • 34548292422 scopus 로고    scopus 로고
    • Commissioning experience with cone-beam computed tomography for image-guided radiation therapy
    • Lehmann J, Perks J, Semon S, Harse R, Purdy JA. Commissioning experience with cone-beam computed tomography for image-guided radiation therapy. J Appl Clin Med Phys. 2007;8(3):21-36.
    • (2007) J Appl Clin Med Phys , vol.8 , Issue.3 , pp. 21-36
    • Lehmann, J.1    Perks, J.2    Semon, S.3    Harse, R.4    Purdy, J.A.5
  • 7
    • 0023381475 scopus 로고
    • Marching Cubes: A high resolution 3D surface construction algorithm. Proceedings of the 1987 ACM Special Interest Group on Computer Graphics and Interactive Techniques
    • Lorensen WE, Cline HE. Marching Cubes: A high resolution 3D surface construction algorithm. Proceedings of the 1987 ACM Special Interest Group on Computer Graphics and Interactive Techniques. Computer Graphics 1987;21(4):163-69.
    • (1987) Computer Graphics , vol.21 , Issue.4 , pp. 163-169
    • Lorensen, W.E.1    Cline, H.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.