Morphological studies on machined implants of commercially pure titanium and titanium alloy (Ti6Al4V) in the rabbit

Author keywords

Embedding resins; FIB; Histology; Osseointegration; Titanium; Titanium alloy

Indexed keywords

BONE AREA; BONE CONTACTS; BONE RESPONSE; COMMERCIALLY PURE TITANIUMS; EMBEDDING RESINS; FIB; FOCUSED ION BEAM MICROSCOPY; HISTOLOGICAL EVALUATION; IMPLANT SURFACE; INTERFERENCE MICROSCOPY; MORPHOLOGICAL STUDY; OSSEOINTEGRATION; RABBIT TIBIA; SURFACE CRYSTALLINITY; TEM; TI-6AL-4V; TI-6AL-4V ALLOY; ULTRA-THIN;

EID: 70049107724     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31404     Document Type: Article
Times cited : (43)

References (35)
  • 2
    • 15944378898 scopus 로고    scopus 로고
    • Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols
    • Guilherme AS, Henriques GE, Zavanelli RA, Mesquita MF. Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols. J Prosthet Dent 2005;93:378-385.
    • (2005) J Prosthet Dent , vol.93 , pp. 378-385
    • Guilherme, A.S.1    Henriques, G.E.2    Zavanelli, R.A.3    Mesquita, M.F.4
  • 3
    • 10644243646 scopus 로고    scopus 로고
    • A comparison of the fatigue behavior of cast Ti-7.5Mo with c.p. titanium. Ti-6Al-4V and Ti-13Nb-13Zr alloys
    • Lin CW, Ju CP, Chern Lin JH. A comparison of the fatigue behavior of cast Ti-7.5Mo with c.p. titanium. Ti-6Al-4V and Ti-13Nb-13Zr alloys. Biomaterials 2005;26:2899-2907.
    • (2005) Biomaterials , vol.26 , pp. 2899-2907
    • Lin, C.W.1    Ju, C.P.2    Chern Lin, J.H.3
  • 5
    • 0000596663 scopus 로고
    • A quantitative comparison of the cell response to commercially pure titanium and Ti-6AI-4V implants in the abdominal wall of rats
    • Johansson CB, Albrektsson T, Ericson LE, Thomsen P. A quantitative comparison of the cell response to commercially pure titanium and Ti-6AI-4V implants in the abdominal wall of rats. J Mater Sci: Mater Med 1992;3:126-136.
    • (1992) J Mater Sci: Mater Med , vol.3 , pp. 126-136
    • Johansson, C.B.1    Albrektsson, T.2    Ericson, L.E.3    Thomsen, P.4
  • 6
    • 0031995906 scopus 로고    scopus 로고
    • Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants
    • Han CH, Johansson CB, Wennerberg A, Albrektsson T. Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants. Clin Oral Implants Res 1998;9:1-10. (Pubitemid 128657959)
    • (1998) Clinical Oral Implants Research , vol.9 , Issue.1 , pp. 1-10
    • Han, C.-H.1    Johansson, C.B.2    Wennerberg, A.3    Albrektsson, T.4
  • 7
    • 0027555843 scopus 로고
    • Commercially pure titanium and Ti6A14V implants with and without nitrogen-ion implantation: Surface characterization and quantitative studies in rabbit cortical bone
    • DOI 10.1007/BF00120382
    • Johansson C, Lausmaa J, Röstlund T, Thomsen P. Commercially pure titanium and Ti6Al4V implants with and without nitrogen-ion implantation: Surface characterization and quantitative studies in rabbit cortical bone. J Mater Sci: Mater Med 1993;4:132-141. (Pubitemid 23153225)
    • (1993) Journal of Materials Science: Materials in Medicine , vol.4 , Issue.2 , pp. 132-141
    • Johansson, C.B.1    Lausmaa, J.2    Rostlund, T.3    Thomsen, P.4
  • 8
    • 0037946981 scopus 로고    scopus 로고
    • 4V dental implants
    • DOI 10.1034/j.1600-0501.2003.140108.x
    • De Maeztu MA, Alava JI, Gay-Escoda C. Ion implantation: surface treatment for improving the bone integration of titanium and Ti6Al4V dental implants. Clin Oral Implants Res 2003;14:57-62. (Pubitemid 37490591)
    • (2003) Clinical Oral Implants Research , vol.14 , Issue.1 , pp. 57-62
    • De Maeztu, M.A.1    Alava, J.I.2    Gay-Escoda, C.3
  • 10
    • 0024586373 scopus 로고
    • Ultrastructural differences of the interface zone between bone and Ti 6Al 4V or commercially pure titanium
    • DOI 10.1016/0141-5425(89)90158-1
    • Johansson C, Lausmaa J, Ask M, Hansson HA, Albrektsson T. Ultrastructural differences of the interface zone between bone and Ti 6Al 4V or commercially pure titanium. J Biomed Eng 1989;11:3-8. (Pubitemid 19056124)
    • (1989) Journal of Biomedical Engineering , vol.11 , Issue.1 , pp. 3-8
    • Johansson, C.1    Lausmaa, J.2    Ask, M.3    Hansson, H.-A.4    Albrektsson, T.5
  • 11
    • 0022384322 scopus 로고
    • High-resolution microscopy of the implant-tissue interface
    • Linder L. High-resolution microscopy of the implant-tissue interface. Acta Orthop Scand 1985;56:269-272.
    • (1985) Acta Orthop Scand , vol.56 , pp. 269-272
    • Linder, L.1
  • 12
    • 0022386465 scopus 로고
    • Light and transmission electron microscopy used to study the tissue morphology close to implants
    • DOI 10.1016/0142-9612(85)90104-8
    • Thomsen P, Ericson LE. Light and transmission electron microscopy used to study the tissue morphology close to implants. Biomaterials 1985;6:421-424. (Pubitemid 16218277)
    • (1985) Biomaterials , vol.6 , Issue.6 , pp. 421-424
    • Thomsen, P.1    Ericson, L.E.2
  • 15
    • 56749150886 scopus 로고    scopus 로고
    • Technique for preparation and characterization in cross-section of oral titanium implant surfaces using focused ion beam and transmission electron microscopy
    • Jarmar T, Palmquist A, Branemark R, Hermansson L, Engqvist H, Thomsen P. Technique for preparation and characterization in cross-section of oral titanium implant surfaces using focused ion beam and transmission electron microscopy. J Biomed Mater Res A 2008;87:1003-1009.
    • (2008) J Biomed Mater Res A , vol.87 , pp. 1003-1009
    • Jarmar, T.1    Palmquist, A.2    Branemark, R.3    Hermansson, L.4    Engqvist, H.5    Thomsen, P.6
  • 16
    • 0019947037 scopus 로고
    • A method for the study of undecalcified bones and teeth with attached soft tissues. the Sage-Schliff (sawing and grinding) technique
    • Donath K, Breuner G. A method for the study of undecalcified bones and teeth with attached soft tissues. The Sage-Schliff (sawing and grinding) technique. J Oral Pathol 1982;11:318-326. (Pubitemid 12092572)
    • (1982) Journal of Oral Pathology , vol.11 , Issue.4 , pp. 318-326
    • Donath, K.1    Breuner, G.2
  • 17
    • 0024302285 scopus 로고
    • Preparation and surface spectroscopic characterization of oxide-films on Ti6a14v
    • Ask M, Lausmaa J, Kasemo B. Preparation and surface spectroscopic characterization of oxide-films on Ti6a14v. Appl Surf Sci 1989;35:283-301.
    • (1989) Appl Surf Sci , vol.35 , pp. 283-301
    • Ask, M.1    Lausmaa, J.2    Kasemo, B.3
  • 18
    • 0025475011 scopus 로고
    • Microstructure and morphology of surface oxide films on Ti-6Al-4V
    • Ask M, Rolander U, Lausmaa J, Kasemo B. Microstructure and morphology of surface oxide-films on Ti-6al-4v. J Mater Res 1990;5:1662-1667. (Pubitemid 20722725)
    • (1990) Journal of Materials Research , vol.5 , Issue.8 , pp. 1662-1667
    • Ask, M.1    Rolander, U.2    Lausmaa, J.3    Kasemo, B.4
  • 20
    • 0027592281 scopus 로고
    • Early tissue response to titanium implants inserted in rabbit cortical bone. I. Light microscopic observations
    • Sennerby L, Thomsen P, Ericson LE. Early tissue response to titanium implants inserted in rabbit cortical bone. I. Light microscopic observations. J Mater Sci:Mater Med 1993;4:240-250.
    • (1993) J Mater Sci:Mater Med , vol.4 , pp. 240-250
    • Sennerby, L.1    Thomsen, P.2    Ericson, L.E.3
  • 21
    • 0342601513 scopus 로고    scopus 로고
    • Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat
    • DOI 10.1016/S0142-9612(97)00018-5, PII S0142961297000185
    • Branemark R, Ohrnell LO, Nilsson P, Thomsen P. Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat. Biomaterials 1997;18:969-978. (Pubitemid 27296557)
    • (1997) Biomaterials , vol.18 , Issue.14 , pp. 969-978
    • Branemark, R.1    Ohrnell, L.-O.2    Nilsson, P.3    Thomsen, P.4
  • 24
    • 0028518655 scopus 로고
    • Bone response to surface modified titanium implants: Studies on electropolished implants with different oxide thicknesses and morphology
    • DOI 10.1016/0142-9612(94)90092-2
    • Larsson C, Thomsen P, Lausmaa J, Rodahl M, Kasemo B, Ericson LE. Bone response to surface modified titanium implants: Studies on electropolished implants with different oxide thicknesses and morphology. Biomaterials 1994;15:1062-1074. (Pubitemid 24345933)
    • (1994) Biomaterials , vol.15 , Issue.13 , pp. 1062-1074
    • Larsson, C.1    Thomsen, P.2    Lausmaa, J.3    Rodahl, M.4    Kasemo, B.5    Ericson, L.E.6
  • 26
    • 0035293976 scopus 로고    scopus 로고
    • Histomorphometric comparison of implant anchorage for two types of dental implants after 3 and 6 months' healing in baboon jaws
    • Carr AB, Larsen PE, Gerard DA. Histomorphometric comparison of implant anchorage for two types of dental implants after 3 and 6 months' healing in baboon jaws. J Prosthet Dent 2001;85:276-280.
    • (2001) J Prosthet Dent , vol.85 , pp. 276-280
    • Carr, A.B.1    Larsen, P.E.2    Gerard, D.A.3
  • 28
    • 0842332816 scopus 로고    scopus 로고
    • A comparison of resins for embedding teeth, with special emphasis on adaptation to enamel surface as evaluated by scanning electron microscopy
    • DOI 10.1016/S0003-9969(03)00194-8
    • Li C, Risnes S. A comparison of resins for embedding teeth, with special emphasis on adaptation to enamel surface as evaluated by scanning electron microscopy. Arch Oral Biol 2004;49:77-83. (Pubitemid 38161743)
    • (2004) Archives of Oral Biology , vol.49 , Issue.1 , pp. 77-83
    • Li, C.1    Risnes, S.2
  • 29
    • 0029067550 scopus 로고
    • The biological reality of the interlacunar network in the embryonic, cartilaginous, skeleton: A thiazine dye/absolute ethanol/LR white resin protocol for visualizing the network with minimal tissue shrinkage
    • Lawton DM, Oswald WB, McClure J. The biological reality of the interlacunar network in the embryonic, cartilaginous, skeleton: A thiazine dye/absolute ethanol/LR white resin protocol for visualizing the network with minimal tissue shrinkage. J Microsc 1995;178(Pt 1):66-85.
    • (1995) J Microsc , vol.178 , Issue.PART 1 , pp. 66-85
    • Lawton, D.M.1    Oswald, W.B.2    McClure, J.3
  • 30
    • 5444236172 scopus 로고    scopus 로고
    • Oral implant surfaces. I. Review focusing on topographic and chemical properties of different surfaces and in vivo responses to them
    • Albrektsson T, Wennerberg A. Oral implant surfaces. I. Review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. Int J Prosthodont 2004;17:536-543.
    • (2004) Int J Prosthodont , vol.17 , pp. 536-543
    • Albrektsson, T.1    Wennerberg, A.2
  • 31
    • 0023917424 scopus 로고
    • Surface spectroscopic characterization of titanium implants after separation from plastic-embedded tissue
    • DOI 10.1016/0142-9612(88)90098-1
    • Lausmaa J, Linder L. Surface spectroscopic characterization of titanium implants after separation from plastic-embedded tissue. Biomaterials 1988;9:277-280. (Pubitemid 18150993)
    • (1988) Biomaterials , vol.9 , Issue.3 , pp. 277-280
    • Lausmaa, J.1    Linder, L.2
  • 32
    • 0010384708 scopus 로고
    • Ultrastructural analysis of the interface zone of titanium and gold implants
    • Albrektsson T, Lee AJC, Brånemark PI, editors. Chichester: Wiley
    • Albrektsson T, Brånemark PI, Hansson HA, Ivarsson B, Jönsson U. Ultrastructural analysis of the interface zone of titanium and gold implants. In: Albrektsson T, Lee AJC, Brånemark PI, editors. Advances in Biomaterials. Chichester: Wiley; 1982. pp 167-177.
    • (1982) Advances in Biomaterials , pp. 167-177
    • Albrektsson, T.1    Brånemark, P.I.2    Hansson, H.A.3    Ivarsson, B.4    Jönsson, U.5
  • 33
    • 0026815484 scopus 로고
    • Light and transmission electron microscopy of the intact interfaces between non-submerged titanium-coated epoxy resin implants and bone or gingiva
    • Listgarten MA, Buser D, Steinemann SG, Donath K, Lang NP, Weber HP. Light and transmission electron microscopy of the intact interfaces between non-submerged titanium-coated epoxy resin implants and bone or gingiva. J Dent Res 1992;71:364-371.
    • (1992) J Dent Res , vol.71 , pp. 364-371
    • Listgarten, M.A.1    Buser, D.2    Steinemann, S.G.3    Donath, K.4    Lang, N.P.5    Weber, H.P.6
  • 35
    • 39449087380 scopus 로고    scopus 로고
    • Forearm bone-anchored amputation prosthesis: A case study on the osseointegration
    • DOI 10.1080/17453670710014806, PII 790661336
    • Palmquist A, Jarmar T, Emanuelsson L, Branemark R, Engqvist H, Thomsen P. Forearm bone anchored amputation prosthesis: A case study on the osseointegration. Acta Orthopaedica 2008;79:78-85. (Pubitemid 351271887)
    • (2008) Acta Orthopaedica , vol.79 , Issue.1 , pp. 78-85
    • Palmquist, A.1    Jarmar, T.2    Emanuelsson, L.3    Branemark, R.4    Engqvist, H.5    Thomsen, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.