메뉴 건너뛰기




Volumn 91, Issue 1, 2009, Pages 441-451

Evaluation of drug-eluting stents' coating durability - Clinical and regulatory implications

Author keywords

Coating; Drug eluting stents; Safety; Testing

Indexed keywords

COATED STENTS; COATING DEFECTS; COATING MODEL; COATING PROPERTIES; DELETERIOUS EFFECTS; DRUG RELEASE; DRUG-ELUTING STENTS; DURABILITY TEST; FOOD AND DRUG ADMINISTRATION; IN-VITRO; LIGHT MICROSCOPY; SAFETY; SAFETY ISSUES; SPRAY COATING; STENT COATINGS; SURFACE ADHESION; TESTING METHODOLOGY;

EID: 70049092349     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31420     Document Type: Article
Times cited : (50)

References (24)
  • 1
    • 23044477166 scopus 로고    scopus 로고
    • Drug-eluting stents: The third revolution in percutaneous coronary intervention
    • Saia F, Marzocchi A, Serruys PW. Drug-eluting stents: The third revolution in percutaneous coronary intervention. Ital Heart J 2005;6:289-303.
    • (2005) Ital Heart J , vol.6 , pp. 289-303
    • Saia, F.1    Marzocchi, A.2    Serruys, P.W.3
  • 2
    • 33750215672 scopus 로고    scopus 로고
    • Are drug-eluting stents cost-effective? It depends on whom you ask
    • Ryan AJ, Cohen DJ. Are drug-eluting stents cost-effective? It depends on whom you ask. Circulation 2006;114:1736-1744.
    • (2006) Circulation , vol.114 , pp. 1736-1744
    • Ryan, A.J.1    Cohen, D.J.2
  • 3
    • 34250718778 scopus 로고    scopus 로고
    • Drug-eluting stents: Trading restenosis for thrombosis?
    • DOI 10.1111/j.1538-7836.2007.02486.x, State of the Art 2007: XXI Congress of the International Society on Thrombosis and Haemostasis
    • Belle EV, Susen S, Jude B, Bertrand ME. Drug eluting stents: Trading restenosis for thrombosis. J Thromb Haemost 2007;5:238-245. (Pubitemid 46958839)
    • (2007) Journal of Thrombosis and Haemostasis , vol.5 , Issue.SUPPL. 1 , pp. 238-245
    • Van Belle, E.1    Susen, S.2    Jude, B.3    Bertrand, M.E.4
  • 5
    • 36248951692 scopus 로고    scopus 로고
    • A current problem in cardiology: Very late thrombosis after implantation of sirolimus eluting stent
    • DOI 10.1159/000096989
    • Sharifkazemi MB, Zamirian M, Aslani A. A current problem in cardiology: Very late thrombosis after implantation of sirolimus-eluting stents. Cardiology 2007;108:273-274. (Pubitemid 350126470)
    • (2007) Cardiology , vol.108 , Issue.4 , pp. 273-274
    • Sharifkazemi, M.B.1    Zamirian, M.2    Aslani, A.3
  • 6
    • 36048946708 scopus 로고    scopus 로고
    • Long-Term Clinical Follow-up of Sirolimus-Eluting (CYPHERtm) Coronary Stents in the Treatment of InStent Restenosis in an Unselected Population
    • DOI 10.1016/j.hlc.2007.02.090, PII S1443950607001321
    • Ruchin PE, Muller DW, Faddy SC, Baron DW, Roy PR, Wilson SH. Long-term clinical follow-up of sirolimus-eluting (cyphertm) coronary stents in the treatment of instent restenosis in an unselected population. Heart Lung Circ 2007;16:440-446. (Pubitemid 350091402)
    • (2007) Heart Lung and Circulation , vol.16 , Issue.6 , pp. 440-446
    • Ruchin, P.E.1    Muller, D.W.M.2    Faddy, S.C.3    Baron, D.W.4    Roy, P.R.5    Wilson, S.H.6
  • 7
  • 8
    • 33847284603 scopus 로고    scopus 로고
    • Scanning electron microscopic analysis of defects in polymer coatings of three commercially available stents: Comparison of BiodivYsio, Taxus and Cypher Stents
    • Otsuka Y, Chronos NAF, Apkarian RP, Robinson KA. Scanning electron microscopic analysis of defects in polymer coatings of three commercially available stents: Comparison of BiodivYsio, Taxus and Cypher Stents. J Invasive Cardiol 2007;19:71-76.
    • (2007) J Invasive Cardiol , vol.19 , pp. 71-76
    • Otsuka, Y.1    Chronos, N.A.F.2    Apkarian, R.P.3    Robinson, K.A.4
  • 9
    • 37349035313 scopus 로고    scopus 로고
    • Late coronary late thrombosis
    • Windecker S, Mierer B. Late coronary late thrombosis. Circulation 2007;116:1952-1965.
    • (2007) Circulation , vol.116 , pp. 1952-1965
    • Windecker, S.1    Mierer, B.2
  • 10
    • 35348937713 scopus 로고    scopus 로고
    • Drug-eluting stent safety
    • Slottow T, Waksman R. Drug-eluting stent safety. Am J Cardiol 2007;100(8B):10M-17M.
    • (2007) Am J Cardiol , vol.100 , Issue.8 B
    • Slottow, T.1    Waksman, R.2
  • 11
    • 37349060283 scopus 로고    scopus 로고
    • Update on drug-eluting stents
    • Sims J. Update on drug-eluting stents. Dimens Crit Care Nurs 2007;26:237-240.
    • (2007) Dimens Crit Care Nurs , vol.26 , pp. 237-240
    • Sims, J.1
  • 13
    • 38749105123 scopus 로고    scopus 로고
    • Drug-eluting stents: Do the risks really overweigh the benefits?
    • Austin D, Pell JP, Oldroyd KG. Drug-eluting stents: Do the risks really overweigh the benefits? Heart 2008;94:127-128.
    • (2008) Heart , vol.94 , pp. 127-128
    • Austin, D.1    Pell, J.P.2    Oldroyd, K.G.3
  • 14
    • 38749108516 scopus 로고    scopus 로고
    • Drug-eluting stents - A critique
    • Melikian N, Wijns W. Drug-eluting stents - A critique. Heart 2008;94:145-152.
    • (2008) Heart , vol.94 , pp. 145-152
    • Melikian, N.1    Wijns, W.2
  • 17
    • 33646537791 scopus 로고    scopus 로고
    • Regulatory issues facing the development of drug-eluting stents: A US FDA perspective
    • Boam AB. Regulatory issues facing the development of drug-eluting stents: A US FDA perspective. Expert Rev Med Devices 2006;3:297-300.
    • (2006) Expert Rev Med Devices , vol.3 , pp. 297-300
    • Boam, A.B.1
  • 18
    • 17144427013 scopus 로고    scopus 로고
    • Cardiovascular device development: Drug-eluting stents and implantable devices for the treatment of heart failure - The view from the Circulatory System Advisory Panel
    • Laskey WK. Cardiovascular device development: Drug-eluting stents and implantable devices for the treatment of heart failure - The view from the Circulatory System Advisory Panel. Am J Ther 2005;12:179-182.
    • (2005) Am J Ther , vol.12 , pp. 179-182
    • Laskey, W.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.