Volumn 25, Issue 4, 2009, Pages 272-278

Enzyme conductometric biosensor for maltose determination

Author keywords

Conductometric biosensor; Glucose oxidase; Maltose; Mutarotase; glucosidase

Indexed keywords

ALPHA GLUCOSIDASE; GLUCOSE; GLUCOSE OXIDASE; GOLD; MALTOSE;

EID: 69949138475     PISSN: 02337657     EISSN: 19936842     Source Type: Journal    
DOI: 10.7124/bc.0007E6     Document Type: Article
Times cited : (14)

References (18)
  • 3
    • 0030024901 scopus 로고    scopus 로고
    • Enzymatic membranes for determination of some disacchrides by means of oxygen electrode
    • Filipiak M., Fludra K., Gosciminska E. Enzymatic membranes for determination of some disacchrides by means of oxygen electrode. Biosensors and Bioelectronics 1996 11, N 4 P. 355-364.
    • (1996) Biosensors and Bioelectronics , vol.11 , Issue.4 , pp. 355-364
    • Filipiak, M.1    Fludra, K.2    Gosciminska, E.3
  • 4
    • 0030763954 scopus 로고    scopus 로고
    • Studies on dynamic behavior of the biosensor based on immobilized glucoamylase-glucose oxidase membrane
    • Gondo S., Kim C., Hirata S., Morishita M. Studies on dynamic behavior of the biosensor based on immobilized glucoamylase-glucose oxidase membrane. Biosensors and Bioelectronics 1997 12, N 5 P. 395-401.
    • (1997) Biosensors and Bioelectronics , vol.12 , Issue.5 , pp. 395-401
    • Gondo, S.1    Kim, C.2    Hirata, S.3    Morishita, M.4
  • 5
    • 84946525864 scopus 로고    scopus 로고
    • Simultaneous determination of maltose and glucose using a screen-printed electrode system
    • Ge F., Zhang X. E., Zhang P., Zhang X. M. Simultaneous determination of maltose and glucose using a screen-printed electrode system. Antonie Van Leeuwenhoek 1997 71, N 4 P. 345-351.
    • (1997) Antonie Van Leeuwenhoek , vol.71 , Issue.4 , pp. 345-351
    • Ge, F.1    Zhang, X.E.2    Zhang, P.3    Zhang, X.M.4
  • 6
    • 0029585913 scopus 로고
    • Development of biosensors based on an electrolyte isolator semiconductor (EIS)-capacitor structure and their application for process monitoring. Part I. Development of the biosensors and their characterization
    • Menzel C., Lerch T., Scheper T., Schugerl K. Development of biosensors based on an electrolyte isolator semiconductor (EIS)-capacitor structure and their application for process monitoring. Part I. Development of the biosensors and their characterization. Anal. Chim. Acta 1995 317, N 1-3 P. 259-264.
    • (1995) Anal. Chim. Acta , vol.317 , Issue.1-3 , pp. 259-264
    • Menzel, C.1    Lerch, T.2    Scheper, T.3    Schugerl, K.4
  • 7
    • 84946526348 scopus 로고
    • Studying the bienzyme reaction with amperometric detection for measuring maltose
    • Varadi M., Àdanyi N., Nagy G., Rezessy-Szabo J. Studying the bienzyme reaction with amperometric detection for measuring maltose. Biochimie 1980 62, N 8-9 P. 587-593.
    • (1980) Biochimie , vol.62 , Issue.8-9 , pp. 587-593
    • Varadi, M.1    Àdanyi, N.2    Nagy, G.3    Rezessy-Szabo, J.4
  • 9
    • 0028018835 scopus 로고
    • Application of enzymefield effect transistor sensor arrays as detectors in a flowinjection analysis system for simultaneous monitoring of medium components. Part I. Preparation and calibration
    • Kullick T., Beyer M., Henning J., Lerch T., Quack R., Zeitz A., Hitzmann B., Scheper T., Schugerl K. Application of enzymefield effect transistor sensor arrays as detectors in a flowinjection analysis system for simultaneous monitoring of medium components. Part I. Preparation and calibration. Anal. Chim. Acta 1994 296 P. 263-269.
    • (1994) Anal. Chim. Acta , vol.296 , pp. 263-269
    • Kullick, T.1    Beyer, M.2    Henning, J.3    Lerch, T.4    Quack, R.5    Zeitz, A.6    Hitzmann, B.7    Scheper, T.8    Schugerl, K.9
  • 11
    • 0028868274 scopus 로고
    • Application of enzyme-field effect transistor sensor arrays as detectors in a flow-injection analysis system for simultaneous monitoring of medium components. Part II. Monitoring of cultivation processes
    • Kullick T., Bock U., Schubert J., Scheper T., Schugerl K. Application of enzyme-field effect transistor sensor arrays as detectors in a flow-injection analysis system for simultaneous monitoring of medium components. Part II. Monitoring of cultivation processes. Anal. Chim. Acta 1995 300 P. 25-31.
    • (1995) Anal. Chim. Acta , vol.300 , pp. 25-31
    • Kullick, T.1    Bock, U.2    Schubert, J.3    Scheper, T.4    Schugerl, K.5
  • 12
    • 0037164176 scopus 로고    scopus 로고
    • Integration of bienzymatic disaccharide sensors for simultaneous determination of disaccharides by means of light addressable potentiometric sensor
    • Aoki K., Uchida H., Katsube T., Ishimaru Y., Iida T. Integration of bienzymatic disaccharide sensors for simultaneous determination of disaccharides by means of light addressable potentiometric sensor. Anal. Chim. Acta 2002 471 P. 3-12.
    • (2002) Anal. Chim. Acta , vol.471 , pp. 3-12
    • Aoki, K.1    Uchida, H.2    Katsube, T.3    Ishimaru, Y.4    Iida, T.5
  • 13
    • 0029053713 scopus 로고
    • Flow injection amperometric determination of glucose and some other low molecular weight saccharides based on oligosaccharide dehydrogenase mediated by benzoquinone systems
    • Tessema M., Ruzgas T., Gorton L., Ikeda T. Flow injection amperometric determination of glucose and some other low molecular weight saccharides based on oligosaccharide dehydrogenase mediated by benzoquinone systems. Anal. Chim. Acta 1995 310 P. 161-171.
    • (1995) Anal. Chim. Acta , vol.310 , pp. 161-171
    • Tessema, M.1    Ruzgas, T.2    Gorton, L.3    Ikeda, T.4
  • 14
    • 0030216622 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of carbohydrates at a molecular deposition film electrode based on water-soluble cobalt phthalocyanine and its application to flow-through detection
    • Sun C., Zhang X., Jiang D., Gao Q., Xu H., Sun Y., Zhang X., Shen J. Electrocatalytic oxidation of carbohydrates at a molecular deposition film electrode based on water-soluble cobalt phthalocyanine and its application to flow-through detection. J. Electroanal. Chem 1996 411, N 1-2 P. 73-78.
    • (1996) J. Electroanal. Chem , vol.411 , Issue.1-2 , pp. 73-78
    • Sun, C.1    Zhang, X.2    Jiang, D.3    Gao, Q.4    Xu, H.5    Sun, Y.6    Zhang, X.7    Shen, J.8
  • 15
    • 0028477885 scopus 로고
    • Conductometric method of measurements in enzyme analysis
    • Dzyadevych S. V., Soldatkin O. P. Conductometric method of measurements in enzyme analysis. Ukr. Biochem. J 1994 66, N 4 P. 30-42.
    • (1994) Ukr. Biochem. J , vol.66 , Issue.4 , pp. 30-42
    • Dzyadevych, S.V.1    Soldatkin, O.P.2
  • 16
    • 42949137691 scopus 로고    scopus 로고
    • Conductometric enzyme biosensors theory, technology and application
    • Dzyadevych S. V. Conductometric enzyme biosensors theory, technology and application. Biopolymers and Cell 2005 21, N 2 P. 91-106.
    • (2005) Biopolymers and Cell , vol.21 , Issue.2 , pp. 91-106
    • Dzyadevych, S.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.